TITLE

The Fourier Spectrometer as a Holographic Micro-Object Imaging System in Low-Coherence Light

AUTHOR(S)
Kalenkov, S.; Kalenkov, G.; Shtanko, A.
PUB. DATE
February 2013
SOURCE
Measurement Techniques;Feb2013, Vol. 55 Issue 11, p1256
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A new method of obtaining images of microobjects by processing digital interferograms, recorded using a modified Fourier spectrometer, is proposed. The process by which interferograms, which image the spatial characteristics of a microobject, are formed, is described. The requirements imposed on the width of the source radiation spectrum in order to transmit the spatial structure of the object are discussed. Results of an experiment to record the image of a microobject in white light are presented.
ACCESSION #
85923803

 

Related Articles

  • Simple interface between electrochemical systems and FTIR spectrometers. Holze, R.; Freisenich, U.; Stach, W. // Review of Scientific Instruments;Dec1988, Vol. 59 Issue 12, p2625 

    An electronic interface connecting the potentiostat of an electrochemical measurement system to a Fourier transform infrared (FTIR) spectrometer as used for in situ IR reflection absorption studies is described. It makes use of readily available components, is installed without any changes in...

  • Multi-object spectrometer with micromirror array. Voropai, E.; Gulis, I.; Kupreev, A.; Kaplevskii, K.; Kostyukevich, A.; Radko, A.; Shevchenko, K. // Journal of Applied Spectroscopy;May2010, Vol. 77 Issue 2, p285 

    We have designed and built a multi-object spectrometer with micromirror array as a reconfigurable entrance aperture. In interactive mode, the instrument makes it possible to record both the hyperspectrum of the studied region as a whole and also sets of spectra of arbitrarily specified...

  • Square-shaped metal screens in the infrared to terahertz spectral region: Resonance frequency, band gap, and bandpass filter characteristics. Sternberg, O.; Stewart, K. P.; Hor, Y.; Bandyopadhyay, A.; Federici, J. F.; Bornefeld, M.; Mathis, Y.-L.; Sliwinski, D.; Möller, K. D.; Grebel, H. // Journal of Applied Physics;Jul2008, Vol. 104 Issue 2, p023103 

    Resonance frequency of freestanding, square-shaped thick metal screens have been studied here in the wavelength range of infrared (IR) to mm (20 to 0.2 THz). It was found that their peak transmission has a linear relationship to the screen’s pitch. An experimental spectral feature,...

  • Extending a continuous scan Fourier transform spectrometer for time-resolved Fourier transform spectroscopy with <0.5 cm-1 spectral and <10 ns time resolution in the visible region Lindner, Jorg; Stahlhut, Oliver; Wilhelm, Ralf; Ermisch, Karsten // Review of Scientific Instruments;Apr98, Vol. 69 Issue 4, p1629 

    Describes the extension of continuous scan Fourier transform spectrometer (FTS) for time-resolved FTS (TS-FTS). Characteristics of the FTS; Realization of the data acquisition and experimental setup; Examples of time-resolved measurements; Signal-to-noise behavior of TS-FTS.

  • Inversion of time domain signals from a Balle–Flygare type microwave spectrometer. Campbell, Edward J. // Review of Scientific Instruments;Aug1993, Vol. 64 Issue 8, p2166 

    The method of sine and cosine Fourier transforms with a phase correction, well known in NMR and traveling wave Fourier transform microwave spectroscopy, is examined for the pulsed beam Fabry-Perot cavity. The validity of this approach is closely related to the result, noted previously elsewhere...

  • Phase-modulated ellipsometer using a Fourier transform infrared spectrometer for real time applications. Canillas, A.; Pascual, E.; Drévillon, B. // Review of Scientific Instruments;Aug1993, Vol. 64 Issue 8, p2153 

    A new Fourier transform infrared phase-modulated ellipsometer is presented. It combines the high frequency provided by a photoelastic modulator (37 kHz) with the low frequency of the Fourier transform infrared spectroscopy (<1 kHz), by means of a numerical data acquisition system. A full...

  • Spectral averaging and low-frequency sampling modifications for the IQS 401 fast Fourier transform spectrum analyzer. Smith, Steven W. // Review of Scientific Instruments;Jan1985, Vol. 56 Issue 1, p159 

    The IQS 401 spectrum analyzer, a commercial addition to the Apple II and III personal computers, can be modified for low-cost power spectrum measurements of random noise signals and similar waveforms. The IQS basic control program is changed to perform low-frequency sampling, spectral averaging,...

  • Optical cavity boosts broadband FTS sensitivity. Ruth, Albert A.; Orphal, Johannes // Laser Focus World;Feb2009, Vol. 45 Issue 2, p45 

    The article focuses on the Fourier-transform spectroscopy (FTS), a well-established spectroscopic method, that is used to improve and complement the performance of grating or prism spectrometers. The method is applicable for the measurement of the speed of light, for the definition of the meter...

  • Order received for commercial GC/FTMS.  // LC-GC Europe;May2006, Vol. 19 Issue 5, p10 

    The article reports that Varian Inc. has received an order for its gas chromatogram (GC)/ Fourier transform mass spectrometer (FTMS). The system incorporates a Varian GC with a high performance FTMS that would provide researchers in environmental laboratories with optimum structural elucidation...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics