ABSTRACT
Ion chambers are in common use as beam loss monitors at many accelerators. A unit designed and used at FNAL and later at BNL was proposed for the SNS. Concerns about the ion collection times and low collection efficiency at high loss rates led to improvements to this unit and the design of an alternate chamber with better characteristics. Prototypes have been tested with pulsed beams. The design and test results for both detectors will be presented.
ACCESSION #
8584108

Tags: IONIZATION chambers;  ELECTRON accelerators

 

Related Articles

  • A liquid nitrogen cooled ionizer for a quadrupole mass spectrometer. Farrall, Paul D.; Engel, Thomas // Review of Scientific Instruments;Nov96, Vol. 67 Issue 11, p4027 

    Presents a study that constructed an ultrahigh vacuum compatible cooled ionizer suitable for use with a quadruple mass spectrometer. Capability of the system to monitor rapidly changing signals of condensable gases; Modulated molecular beam studies of surface reaction kinetics with minimal...

  • Interpretation of the outputs from a double ion chamber. Hill, Peter // Review of Scientific Instruments;Jul88, Vol. 59 Issue 7, p1237 

    A double ion chamber can be used to measure absolute intensities of UV light, and the absorptivity and photoionization yield of gases. New methods have been developed and tested which make double ion chambers simpler to build and use. These methods allow for collection regions of unequal length...

  • Automated sample transport system for chromatography/secondary ion mass spectrometry. Duffin, Kevin L.; Flurer, Rick A.; Busch, Kenneth L.; Sexton, Larry W.; Dorsett, John L. // Review of Scientific Instruments;Jun89, Vol. 60 Issue 6, p1071 

    The design of a new sample cell for a large-scale secondary ion mass spectrometer is described. Unique to this new source chamber is the incorporation of large piezoelectric translator stages capable of 20 cm�20 cm movement with high resolution. In addition, the source chamber is designed so...

  • Method for Background Reduction in an Experiment Devoted to WIMP Searches with a Liquid-Xenon (Liquid-Argon) Ionization Chamber. Ovchinnikov, B. M.; Parusov, V. V. // Physics of Atomic Nuclei;Jul2000, Vol. 63 Issue 7, p1301 

    A method for detecting ultraviolet photons from Xe[sup *, sub 2] deexitation with an efficiency of nearly 100% is proposed. This method allows a reliable discrimination between Xe (Ar) recoil nuclei and background electrons. As a result, the � and ? background is almost completely suppressed....

  • Description of ARCAL XXXIV Project: Repair and Calibration of Electrometers and Ionization Chambers Used in Radiotherapy. Cruz-Estrada, P.; Ramirez-Jimenez, F.J.; Villaverde-Lozano, A. // AIP Conference Proceedings;2003, Vol. 682 Issue 1, p192 

    The technological tools for the diagnosis of diseases and treatment of cancer are based mostly on the use of ionizing radiations. This situation worries to the International Atomic Energy Agency (IAEA), which has implemented programs of technical cooperation for the protection of the human...

  • Analytic And Monte Carlo Study Of The Perturbation Factor kp For A Standard Of Dw Through An Ka Standard Ionization Chamber BEV-CC01. Verdosoto, M.X. Vargas; Romero, J.T. Alvarez // AIP Conference Proceedings;2003, Vol. 682 Issue 1, p124 

    Reports on the use of the approach developed by the BIPM for [sup 60]Co gamma radiation in characterizing an ionization chamber BEV-CC01 as a standard of absorbed dose to water D[sub w] at SSDL-Mexico. Estimation of a factor k[sub p] which stems from the perturbation introduced by the presence...

  • Simple �Package Design� Ion Chamber Monitors for TRIUMF�s Proton Beamlines. Gray, Daniel; Minato, Brian // AIP Conference Proceedings;2002, Vol. 648 Issue 1, p439 

    In the beam line designed to supply 100 �A of 500 MeV protons to the two ISAC production targets at TRIUMF, 13 profile monitor stations were required. The design allows each station to be fitted with either an air driven wire scanner module for high currents or an ionization chamber for low...

  • Proposed Profile Monitor Designs for the Advanced Hydrodynamic Facility (AHF). Sellyey, William. C.; O�Hara, James F. // AIP Conference Proceedings;2002, Vol. 648 Issue 1, p275 

    The AHF consists of a LINAC, a booster ring, a 50 GeV Synchrotron and an elaborate set of beam-lines for simultaneously delivering a string of 24 proton bunches from 12 different directions to a firing site (fs) chamber in which an explosion is in progress. This paper will discuss profile...

  • Energy distribution and formation mechanism of fast atoms in a fast atom beam. Shimokawa, Fusao; Kuwano, Hiroki // Journal of Applied Physics;7/1/92, Vol. 72 Issue 1, p13 

    Presents a study that measured the energy distribution of fast atoms produced by modifying a McIlraith-type fast atom beam (FAB) source using a retarding-field energy analyzer coupled with an ionization chamber. Definition of fast atom beam; Characteristics of FAB source; Schematic diagram of...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics