TITLE

Iodine based radiopacity of experimental blood clots for testing of mechanical thrombectomy devices

AUTHOR(S)
Luo, Zhong Hua; Chung, Alex; Choi, Gibok; Lin, Yih Huie; Pang, Huajin; Uchida, Barry T.; Pavčnik, Dušan; Jeromel, Miran; Keller, Frederick S.; Rösch, Josef
PUB. DATE
January 2013
SOURCE
Radiology & Oncology;2013, Vol. 47 Issue 1, p14
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background. Barium sulfate powder used for radiopacity of experimental blood clots (EBCs) for testing mechanical thrombectomy devices (MTD) has negative effects on EBCs mechanical properties. In vitro and in vivo exploration was performed to determine if the iodine based contrast medium will have less negative effects on the EBCs than barium. Materials and methods. Fresh blood from 2 swine was used to create fibrinogen enhanced and thrombin initiated EBC in tubes. Iodine radiopacity was achieved by mixing the blood with 65% Iohexol or by soaking the EBCs for 2 or 24 hours in Iohexol. The EBCs opacified with barium served as controls . In vitro study: The EBCs were subjected to four tests, manual elongation, catheter injection, radiopacity and contrast wash out tests. In vivo study: The common carotid arteries of 2 swine were embolized by either barium EBC or EBC soaked for 24 hours in Iohexol. The duration of radiopacity of the different EBCs was compared. Results. The EBCs opacified with Iohexol initially had higher radiopacity than the barium opacified EBCs. However, their opacity rapidly decreased with saline soaking and, particularly, after they were embolized in live animals. The mechanical properties of Iohexol opacified EBCs were inferior to barium opacified EBCs. The Iohexol mixed EBCs were less firm and elastic and half of them fragmented during catheter injection. The Iohexol soaked EBCs exhibited decreased tensile strength and elasticity compared to the barium EBCs. Conclusions. Compared to barium, iodine based contrast medium does not offer any advantage for opacifying EBCs.
ACCESSION #
85401325

 

Related Articles

  • Optimization of dual-saturation single bolus acquisition for quantitative cardiac perfusion and myocardial blood flow maps. Sánchez-González, Javier; Fernandez-Jiménez, Rodrigo; Nothnagel, Nils D.; López-Martín, Gonzalo; Fuster, Valentin; Ibañez, Borja // Journal of Cardiovascular Magnetic Resonance (BioMed Central);2015, Vol. 17 Issue 1, p1 

    Background: In-vivo quantification of cardiac perfusion is of great research and clinical value. The dual-bolus strategy is universally used in clinical protocols but has known limitations. The dual-saturation acquisition strategy has been proposed as a more accurate alternative, but has not...

  • X-ray computed tomography of the anterior cruciate ligament and patellar tendon. Shearer, Tom; Rawson, Shelley; Castro, Simon Joseph; Balint, Richard; Bradley, Robert Stephen; Lowe, Tristan; Vila-Comamala, Joan; Lee, Peter David; Cartmell, Sarah Harriet // Muscles, Ligaments & Tendons Journal (MLTJ);2014 Supplement, p238 

    The effect of phosphotungstic acid (PTA) and iodine solution (IKI) staining was investigated as a method of enhancing contrast in the X-ray computed tomography of porcine anterior cruciate ligaments (ACL) and patellar tendons (PT). We show that PTA enhanced surface contrast, but was ineffective...

  • Quantitative contrast-enhanced computed tomography: is there a need for system calibration? Miles, Kenneth A.; Young, Helen; Chica, Sandra L.; Esser, Peter D. // European Radiology;Apr2007, Vol. 17 Issue 4, p919 

    The purpose of the study was to perform phantom studies to assess the impact of computed tomography (CT) system variability on quantitative measurements of contrast enhancement. A phantom containing tubes of contrast material at dilutions of 120, 1:35, 1:50, 1:100 and 1:200 arranged in air or...

  • EXPERIMENTAL BASIC RESEARCH IN NURSING. De Assis Bastos, Maria Lysete // Journal of Nursing UFPE / Revista de Enfermagem UFPE;Special Issue Mar2013, Vol. 7 Issue S, p1 

    The author reviews the scenario of in vitro and in vivo experimental basic researches (EBR) leading to designing of human clinical trials, involving medical and nursing fraternity in Brazil. He comments that preclinical animal research and EBR is hugely neglected by the Brazilian Nursing...

  • Comparison of diffusion tensor imaging by cardiovascular magnetic resonance and gadolinium enhanced 3D image intensity approaches to investigation of structural anisotropy in explanted rat hearts. Bernus, Olivier; Radjenovic, Aleksandra; Trew, Mark L.; LeGrice, Ian J.; Sands, Gregory B.; Magee, Derek R.; Smaill, Bruce H.; Gilbert, Stephen H. // Journal of Cardiovascular Magnetic Resonance (BioMed Central);2015, Vol. 17 Issue 1, p1 

    Background: Cardiovascular magnetic resonance (CMR) can through the two methods 3D FLASH and diffusion tensor imaging (DTI) give complementary information on the local orientations of cardiomyocytes and their laminar arrays. Methods: Eight explanted rat hearts were perfused with Gd-DTPA...

  • VPLIV KONCENTRACIJE JODAV KONTRASTNEM SREDSTVU NA KVALITETO SLIKE PRI RAÄŒUNALNIÅ KITOMOGRAFIJI. Janežič, Aleksandra; Kos, Boštjan // Bulletin: Newsletter of the Society of Radiographers of Slovenia;2012, Vol. 29 Issue 1, p92 

    No abstract available.

  • EFFECT OF IODINE CONCENTRATION IN CONTRAST MEDIUM ON THE COMPUTED TOMOGRAPHY IMAGE QUALITY. Janežič, Aleksandra; Kos, Boštjan // Bulletin: Newsletter of the Society of Radiographers of Slovenia;2012, Vol. 29 Issue 1, p92 

    Introduction and purpose: During CT examinations the patients are given contrast agents intravenously for better tissue differentiation. Contrast agents differ by iodine concentration. When applied intravenously, iodine dilutes in blood and its concentration gradually fades in tissue. This...

  • In vitro evaluation of the sinus sagittalis superior thrombosis model in the rat using 3D micro- and nanocomputed tomography. Langheinrich, Alexander; Yeniguen, Mesut; Ostendorf, Anne; Marhoffer, Simone; Dierkes, Christian; Gerlach, Susanne; Nedelmann, Max; Kampschulte, Marian; Bachmann, Georg; Stolz, Erwin; Gerriets, Tibo // Neuroradiology;Sep2010, Vol. 52 Issue 9, p815 

    Thrombosis of the cerebral veins and sinus are common causes of stroke. Animal models help us to understand the underlying pathophysiology of this condition. Therefore, the purpose of our study was to evaluate a well-established model for sinus sagittalis (SSS) thrombosis using micro- and...

  • Comparative tolerability of contrast media used for coronary interventions. Esplugas, E.; Cequier, A.; Gomez-Hospital, J.A.; Del Blanco, B.G.; Jara, F.; Esplugas, Enrique; Cequier, Angel; Gomez-Hospital, Joan A; Del Blanco, Bruno García; Jara, Francisco // Drug Safety;Dec2002, Vol. 25 Issue 15, p1079 

    Radiographic contrast media (CM) are necessary to provide x-ray absorption of the bloodstream; all other observed effects need to be regarded as adverse. Four types of CM are currently used in diagnostic and interventional cardiology: ionic high-osmolar CM (HOCM), either ionic or non-ionic...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics