TITLE

Secondary Control Strategies for Cycling of Air Conditioning and Refrigeration Systems

AUTHOR(S)
Seshadri, Swarooph Nirmal; Rasmussen, Bryan P.
PUB. DATE
October 2012
SOURCE
ASHRAE Transactions;2012, Vol. 118 Issue 2, p508
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A large percentage of air conditioning and refrigeration systems rely on compressor cycling strategies to meet cooling loads. This paper examines the impact of expansion valve and heat exchanger fan control strategies on system efficiency, assuming an on-off cycle of the compressor . The first step is the development of a start-up/shut-down dynamic simulation model that is used as a tool to understand the effect that valve/fan cycling has on the system's cyclic efficiency. Refrigerant migration due to valve strategies and fan delay at shutdown are determined as crucial issues that have an effect on system's cyclic efficiency. Optimization approaches are then used to search for the optimal cycle strategies. The simulation studies are followed by extensive experimental tests conducted on a 3-ton residential air conditioner , confirming the major conclusions of the simulation study, namely that the valve and fan control strategies during compressor shutdown can result in significant variations in cyclic COP.
ACCESSION #
83754945

 

Related Articles

  • Environmental Noise Case Studies: Air-Cooled Refrigeration Chiller Installations near Residential Structures. Evans, Jack B.; Himmel, Chad N.; Leasure, Joshua D. // ASHRAE Transactions;2012, Vol. 118 Issue 2, Special section p50 

    The air conditioning design process includes decisions to use outdoor air-cooled refrigeration chillers or indoor chiller with outdoor cooling tower. Many air- cooled chillers utilize screw or rotary helical compressors, which emit very tonal noise and vibration in the outdoor environment....

  • Reactions of Chiller Maintain Efficiency.  // Air Conditioning, Heating & Refrigeration News;5/1/2006, Vol. 228 Issue 1, p10 

    The article offers information on the advantages of variable speed technology to users of industrial chillers as well as chiller manufacturers. Variable speed, when applied to a refrigeration compressor works to always fit the compressor output to the demand for cooling. The compressor always...

  • Performance Improvement of a Roof Top Air-Conditioning Unit by Refrigerant Circuitry Optimization. Lee, Sunil; Yashar, David A.; Domanski, Piotr A. // ASHRAE Transactions;2013, Vol. 119 Issue 1, Special section p1 

    In this experiment-aided simulation study, we achieved the performance improvement of a Roof Top Unit (RTU) by optimizing an evaporator's refrigerant circuitry using evolutionary algorithms. The system used in this study was a 2-stage 7.5 Ton RTU with an air-to-refrigerant finned-tube evaporator...

  • Theoretical Study of a Novel Four-Chamber Rotary Compressor: Design and Thermodynamic Analysis. Alduqri, Yahya Ahmed; Musa, Md Nor // Applied Mechanics & Materials;2016, Vol. 819, p46 

    A novel four-chamber rotary compressor (FCRC) is being developed for a refrigerator and an air-conditioning system. The novelty lies in the usage of three rotating sleeves and two oppositely installed vanes each has one end fixed to an outer sleeve and the other end to a rotor, respectively. In...

  • The Needed Amount of Condenser Subcooling. Tomczyk, John // Air Conditioning Heating & Refrigeration News;4/2/2012, Vol. 245 Issue 14, p20 

    The article focuses on liquid subcooling in air conditioners or refrigeration.

  • Exergetic efficiency optimization of a thermoacoustic cooler. Chen, L.; Wu, F.; Li, Q.; Guo, F.; Su, A. // Proceedings of the Institution of Mechanical Engineers -- Part C;Nov2007, Vol. 221 Issue 11, p1339 

    A heat transfer model with a complex exponent between a thermoacoustic cooler and its surrounding heat reservoirs is established in the current paper. Both the real part and the imaginary part of the heat transfer exponent strongly affect the optimal performance of the cooler. The exergetic...

  • Past, present and future perspectives of refrigerants in air-conditioning, refrigeration and heat pump applications. SÂRBU, IOAN; VALEA, EMILIAN STEFAN // WSEAS Transactions on Heat & Mass Transfer;2014, Vol. 9, p27 

    The paper presents a study of refrigerants and some issues relating to their environmental impacts in HVAC&R equipment. They are treated aspects of the environmental pollution through the working fluids of the air-conditioning, refrigeration and heat pump systems, and a new strategy in using...

  • DIAGNOSTICS AND OPTIMIZATION OF A MINIATURE HIGH FREQUENCY PULSE TUBE CRYOCOOLER. Garaway, I.; Veprik, A.; Radebaugh, R. // AIP Conference Proceedings;4/9/2010, Vol. 1218 Issue 1, p167 

    A miniature, high energy density, pulse tube cryocooler with an inertance tube and reservoir has been developed, tested, diagnosed and optimized to provide appropriate cooling for size-limited cryogenic applications demanding fast cool down. This cryocooler, originally designed using REGEN 3.2...

  • Admission (Economizer) Port Optimization of a Voorhees Modified Reciprocating CO2 Compressor. Lambers, Klaus J�rgen; S�ss, J�rgen; K�hler, J�rgen // HVAC&R Research;May2007, Vol. 13 Issue 3, p485 

    Admission (the use of an economizer) is a well-known method to reduce the expansion losses of a refrigeration system. The alternative refrigerant carbon dioxide (CO2) has a relatively large isentropic exponent. Therefore, refrigeration systems using CO2 as a refrigerant have a high potential for...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics