TITLE

An amperometric cholesterol biosensor based on epoxy resin membrane bound cholesterol oxidase

AUTHOR(S)
Pundir, C. S.; Narang, Jagriti; Chauhan, Nidhi; Preety; Sharma, Renu
PUB. DATE
October 2012
SOURCE
Indian Journal of Medical Research;Oct2012, Vol. 136 Issue 4, p633
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background & objectives: The use of epoxy resin membrane as a support for immobilization of enzyme has resulted into improved sensitivity and stability of biosensors for uric acid, ascorbic acid and polyphenols. The present work was aimed to prepare an improved amperometric biosensor for determination of serum cholesterol required in the diagnostics and management of certain pathological conditions. Methods: Epoxy resin membrane with immobilized cholesterol oxidase was mounted on the cleaned platinum (Pt) electrode with a parafilm to construct a working electrode. This working electrode along with Ag/AgCl as reference and Ag wire as an auxiliary electrode were connected through a three terminal electrometer to construct a cholesterol biosensor. Results: The sensor showed optimum response within 25 sec at pH 7.0 and 45°C. The linear working range of biosensor was 1.0 to 8.0 mM cholesterol. Km and Imax for cholesterol were 5.0 mM and 9.09 µA, respectively. The biosensor measured serum cholesterol. The minimum detection limit of the sensor was 1.0 mM. The mean analytical recoveries of added cholesterol in serum (2.84 and 4.13 mM) were 91.4±2.8 and 92.3±3.1 per cent (n=6), respectively. Within and between assay coefficient of variation (CV) were <2 and <4 per cent, respectively. Biosensor had a storage life of 6 months at 4°C. Interpretation & conclusions: The use of epoxy resin membrane as a support for immobilization of cholesterol oxidase has resulted into an improved amperometric cholesterol biosensor. The present biosensor had an advantage over the existing biosensors as it worked at comparatively lower potential.
ACCESSION #
83699287

 

Related Articles

  • Reagentless biosensor for phenolic compounds based on tyrosinase entrapped within gelatine film. Nan Li; Min-Hua Xue; Hui Yao; Jun-Jie Zhu // Analytical & Bioanalytical Chemistry;Dec2005, Vol. 383 Issue 7/8, p1127 

    A simple and new reagentless phenolic compound biosensor was constructed with tyrosinase immobilized in the gelatine matrix cross-linked with formaldehyde. The morphologies of gelatine and gelatine/tryosinase were characterized by SEM. The tyrosinase retains its bioactivity when being...

  • Development of a Polypyrrole-Based Amperometric Phosphate Biosensor. Lawal, A. T.; Adeloju, S. B. // Journal of Applied Sciences;2009, Vol. 9 Issue 10, p1907 

    A biosensor is developed by co-entrapment of Purin Nucleoside Phosphorylase (PNP) and xanthine oxidase (XOD) and potassium ferrocyanide (K4Fe(CN)6 into a polypyrrole (PPy) film via., galvanostatic polymerisation of pyrrole. The optimum conditions for formation of the Ppy-PNP-XOD-Fe(CN)64- film...

  • An amperometric monoamine oxidase biosensor for determining some antidepressants. Medyantseva, E. P.; Varlamova, R. M.; Gimaletdinova, D. A.; Fattakhova, A. N.; Budnikov, G. K. // Journal of Analytical Chemistry;Mar2008, Vol. 63 Issue 3, p275 

    An amperometric biosensor based on a platinum screen-printed electrode and immobilized monoamine oxidase is developed to determine antidepressants of different classes. Petylyl, pyrazidol, and flu-oxetine can be determined with determination limits of 8 × 10−9, 8 × 10−7, and...

  • Amperometric determination of xanthine in tea, coffee, and fish meat with graphite rod bound xanthine oxidase. Devi, R.; Narang, J.; Yadav, S.; Pundir, C. // Journal of Analytical Chemistry;Mar2012, Vol. 67 Issue 3, p273 

    A method is described for construction of an amperometric xanthine biosensor based on graphite rod modified through adsorption of xanthine oxidase. Enzymatically produced HO from xanthine was split into 2H + O + 2 at 0.6 V and the current was measured, which was directly proportional to xanthine...

  • Amperometric and Photometric Responses of in Situ Coupled Glucose Oxidase-Poly (Propylene Imine) Dendrimer Based Glucose Biosensor. Shukla, Sudheesh K.; Mishra, Ajay K.; Mamba, Bhekie B.; Arotiba, Omotayo A. // International Journal of Electrochemical Science;Oct2013, Vol. 8 Issue 10, p11711 

    In this work, poly (propylene imine) dendrimer (PPI) was coupled to glucose oxidase enzyme (GOx) in situ and used as a bioreceptor in a glucose biosensor. The coupling was accomplished by the use of 1-ethyl-3-(dimethylaminopropyl) carbodiimide (EDC)/N-hydroxysuccinimide (NHS) linker. Ultraviolet...

  • Bio-sensing using recessed gold-filled capillary amperometric electrodes. Kacanovska, A.; Rong, Z.; Schmidt, M.; Russell, P. St. J.; Vadgama, P. // Analytical & Bioanalytical Chemistry;Oct2010, Vol. 398 Issue 4, p1687 

    novel recessed electrode is reported for amperometric detection of hydrogen peroxide and via glucose oxidase for the detection of glucose. The electrode utilised electrodeposited platinum over a gold wire surface, which proved to be an effective peroxide-detecting surface. Compared with a...

  • Titania sol–gel-derived tyrosinase-based amperometric biosensor for determination of phenolic compounds in water samples. Examination of interference effects. Kochana, J.; Gala, A.; Parczewski, A.; Adamski, J. // Analytical & Bioanalytical Chemistry;Jun2008, Vol. 391 Issue 4, p1275 

    For detection of phenolic compounds in environmental water samples we propose an amperometric biosensor based on tyrosinase immobilized in titania sol–gel. The analytical characteristics toward catechol, p-cresol, phenol, p-chlorophenol, and p-methylcatechol were determined. The linear...

  • Application of nanocomposites based on poly(3,4-ethylenedioxythiophene) in amperometric enzyme biosensors. Shadrina, A. A.; Malev, V. V.; Nikiforova, T. G.; Zigel, V. V.; Pilip, A. G. // Vestnik Sankt-Peterburgskogo universiteta, Seriia 7: Geologia, G;2013, Issue 2, p97 

    In this research the main attention was paid to application of such nanocomposites based on elec-troactive polymer PEDOT (poly(3,4-ethylenedioxythiophene)) as PEDOT/Au and PEDOT/MnO2 that form a peroxide-sensitive layer in choline oxidase amperometric biosensors to determine neu-rotoxins....

  • Fabricating an Amperometric Cholesterol Biosensor by a Covalent Linkage between Poly(3-thiopheneacetic acid) and Cholesterol Oxidase. Po-Chin Nien; Po-Yen Chen; Kuo-Chuan Ho // Sensors (14248220);2009, Vol. 9 Issue 3, p1794 

    In this study, use of the covalent enzyme immobilization method was proposed to attach cholesterol oxidase (ChO) on a conducting polymer, poly(3-thiopheneacetic acid), [poly(3-TPAA)]. Three red-orange poly(3-TPAA) films, named electrodes A, B and C, were electropolymerized on a platinum...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics