ABSTRACT
The paper presents fire design of composite steel-concrete slabs and a description of the use of the advantages o such a structure. Following the review of scientific literature on composite steel-concrete slabs, behaviour under fire temperature may confirm that this solution has no negative consequences for the construction of the building in fire. Profiled steel sheet is a very important building component, because it helps ensuring integrity and insulation properties. Such sheeting serves as a restraint preventing the spread of fire and hot gases, as well as protects the concrete from direct heat action not allowing its chipping off. Fire tests show that the construction of composite steel-concrete slabs without a protective coating under influence of fire is an important bracing frame provided by these conditions. In addition, it may be too conservative to establish the fire resistance coefficient for each element. Maybe it is not necessary to protect all load bearing steal elements in a building from fire, especially when they are in one setup with composite steel-concrete slabs. Fire protection methods make it possible for composite steel-concrete slabs to behave under a plastic bending moment allowing increased temperatures and distributing evenly in an element. The paper provides a brief description of methods for fire design. It analyzes the fire design method according to EN 1994-1-2:2005 regarding unprotected composite steel-concrete slabs exposed to fire from the bottom according to the standard temporary temperature curve. The paper provides an example of the calculation of composite steel-concrete slab according to described method without longitudinal reinforcement and the composite slab with longitudinal reinforcement. Results of calculations let to designate fire resistance of composite slab to heat isolation (I parameter) and the resistance value of the bending moment. Solutions for extra fire protection or increasing bending moment value depend on estimated results.
ACCESSION #
78310154

 

Related Articles

  • Elastic Critical Moment of Lateral-Distortional Buckling of Steel-Concrete Composite Beams under Uniform Hogging Moment. Dias, João Victor Fragoso; Oliveira, Janaina Pena Soares; Calenzani, Adenilcia Fernanda Grobério; Fakury, Ricardo Hallal // International Journal of Structural Stability & Dynamics;Jul2019, Vol. 19 Issue 7, pN.PAG 

    Great attention has been given in the last few years to steel–concrete composite beams due to the gains in strength that can be obtained with the small cost of installing a shear connection between the steel profile and the concrete slab. In continuous and semicontinuous composite beams...

  • A Review of Soft Techniques for Electromagnetic Assessment of Concrete Condition. Queiroz, F. A. A.; Vieira, D. A. G.; Travassos, X. L.; Pantoja, M. F. // Mathematical Problems in Engineering;2012, Vol. 2012, Special section p1 

    This paper describes some efforts to design more efficient analysis for the GPR raw-data interpretation. Such analysis requires algorithms by which problems having complex scattering properties can be solved as accurately and as quickly as possible. This specification is difficult to achieve...

  • A Review of Soft Techniques for Electromagnetic Assessment of Concrete Condition. Queiroz, F. A. A.; Vieira, D. A. G.; Travassos, X. L.; Pantoja, M. F. // Mathematical Problems in Engineering;2012, Vol. 2012, Special section p1 

    This paper describes some efforts to design more efficient analysis for the GPR raw-data interpretation. Such analysis requires algorithms by which problems having complex scattering properties can be solved as accurately and as quickly as possible. This specification is difficult to achieve...

  • Mastering a technology for the lengthwise cutting of continuous-cast slabs. Komel’kov, E.; Popov, A.; Kushnirov, I. // Metallurgist;Nov2004, Vol. 48 Issue 11/12, p562 

    A new technology has been successfully introduced for cutting continuous-cast slabs into semifinished products that are then rolled on a 150 section-rod mill to obtain quality products. Introduction of the technology has freed up some of the deficit capacity of the 1250 blooming mill and the...

  • Levelness Requirements for Unshored Composite Decks.  // Concrete International;Jul2006, Vol. 28 Issue 7, p72 

    The article presents a question and answer advisory pertaining to levelness requirement for unshored concrete slabs. The levelness tolerances for these slabs has not been specified. This issue has been addressed by the Standard Specifications for Tolerances for Concrete Construction and...

  • Floors, Slabs, Face, and More. Gregorski, Tim // Concrete Construction;Oct2009, Vol. 54 Issue 10, p7 

    In this article the author features one of the most respected engineers in the construction industry, Allen Face, and the most contentious and misunderstood topic in the industry, floor slabs. He has invited Face to make a column addressing the issues on concrete floor slabs which will challenge...

  • Full-Scale Test of Two-Storey Composite Slim Floor under Pseudo-Dynamic and Pseudo-Static Loadings. Yang, Lu; Wang, Yuanqing; Shi, Yongjiu // Advances in Structural Engineering;Feb2015, Vol. 18 Issue 2, p173 

    This paper presents an experimental study on a full-scale two-storey, two-bay by one-bay steel-concrete composite slim floor that was subjected to horizontal pseudo-dynamic and cyclic pseudo-static loadings. The primary objective of this test is to investigate the bearing behavior and load...

  • Flexural Response of Steel-Concrete Composite Truss Beams. Luo, Lisheng; Zhang, Xiaofeng // Advances in Civil Engineering;6/12/2019, p1 

    This paper presents an experimental and analytical study on the flexural response of a steel-concrete composite truss beam. This integrated unit consists of a triangular steel truss, a concrete slab on it, and stud connectors. Three simply supported composite trusses with different...

  • Specifying Steel Fibers for Concrete Floors. Garber, George // Construction Specifier;May2014, Vol. 67 Issue 5, p48 

    Thin, short strands of steel are being increasingly specified as reinforcement in ground-supported slabs and in composite steel deck-slabs. Structural engineers are still figuring out how best to design with these components, but specifiers need to think about how to define this material in the...