Stent implantation in the arterial duct of the newborn with duct-dependent pulmonary circulation: single centre experience from Turkey

Odemis, Ender; Haydin, Sertac; Guzeltas, Alper; Ozyilmaz, Isa; Bilici, Meki; Bakir, İhsan
July 2012
European Journal of Cardio-Thoracic Surgery;Jul2012, Vol. 42 Issue 1, p57
Academic Journal
OBJECTIVES Implantation of stents into the ductus arteriosus is an alternative treatment to palliative or corrective cardiac surgery in newborns with duct-dependent pulmonary circulation, although the use of this technique for congenital heart disease is limited. METHODS Between April 2010 and June 2011, 13 patients underwent patent ductus arteriosus stenting after full assessment by echocardiogram and angiogram, two of patients had pulmonary atresia (PA) and ventricular septal defect (VSD), six patients had PA with intact ventricular septum (IVS), four patients had critical pulmonary stenosis with IVS and one single ventricle physiology with PA and four patients had radiofrequency-assisted perforation of the pulmonary valve at the same time. All procedures were retrograde through the femoral artery, except one, which was by the femoral vein approach. RESULTS The mean age and weight during intervention were 10.5 ± 5.7 days and 3.1 ± 0.4 kg, respectively. The mean of procedure and scopy time, time of stay in intensive care, total out-of-hospital and total follow-up time were 138.88 ± 67.11 min; 40.32 ± 25.86 min; 4.88 ± 6.07 days; 11.00 ± 6.89 days and 86.40 ± 73.21 days, respectively. The mean of the radiation amount was 1054.27 ± 1106.91 cGy/cm2. The mean of saturation before and after intervention were 64.44 ± 5.83; 81.88 ± 6.95%, respectively. Procedure-related deaths were observed in two patients. The causes of death were pulmonary haemorrhage (n = 1) and retroperitoneal haemorrhage (n = 1). Two patients also died after discharge before surgery due to sepsis (n = 1) and aspiration pneumonia (n = 1). Eight of 13 patients achieved stent patency during 6 months of follow up and re-stenosis developed in one patient (1/8; 12.5%) who had undergone a Glenn operation at 4.5 months of age. CONCLUSIONS Ductal stenting is a practicable, effective, safer and less invasive method compared palliative or corrective surgery. Patients with ductal stenting have growth of the pulmonary artery which provides additional time for surgical repair. Our data suggested that ductal stenting should be considered as a first treatment step in newborns with duct-depended pulmonary circulation. However, long-term palliation without stent re-stenosismight still be a concern especially in patients with hypoplastic pulmonary arteries.


Related Articles

  • Short-Term Result of Ductus Arteriosus Stent Implantation Compared With Surgically Created Shunts. Amoozgar, Hamid; Cheriki, Sirous; Borzoee, Mohammad; Ajami, Gholamhossein; Soltani, Manouchehr; Ahmadipour, Maryam; Peiravian, Farah; Amirghofran, Amirali // Pediatric Cardiology;Dec2012, Vol. 33 Issue 8, p1288 

    This report aims to compare the researchers' early experience with the safety, efficacy, short-term outcomes, and complications of patent ductus arteriosus (PDA) stents in neonates having duct-dependent pulmonary circulation with those of surgically created shunts. Between April 2009 and April...

  • Device closure of patent ductus arteriosus: optimal guidance by transaortic phased-array imaging. Bartel, Thomas; Gliech, Volker; Müller, Silvana // European Journal of Echocardiography;Feb2011, Vol. 12 Issue 2, pE9 

    In many institutions, device closure of patent ductus arteriosus (PDA) in adult patients is only performed once to twice per year. This report describes an interventional PDA closure procedure being effectively assisted by transaortic phased-array imaging, also known as intracardiac...

  • Suitability of 7 Aortic Stent-Graft Models for MRI- Based Surveillance. Van der Laan, Maarten J.; Bartels, Lambertus W.; Bakker, Chris J. G.; Viergever, Max A.; Blankensteijn, Jan D. // Journal of Endovascular Therapy (Allen Press Publishing Services;Aug2004, Vol. 11 Issue 4, p366 

    Purpose: To evaluate the magnetic resonance imaging (MRI) characteristics of commercially available stent-grafts used for abdominal aortic aneurysm repair. Methods: Seven endovascular grafts (AneuRx, Lifepath, Talent, Excluder, Zenith, Quantum LP, and Ancure) were suspended in a water bath...

  • Comparison of surgical repair and percutaneous stent implantation for native coarctation of the aorta in patients >15 years of age. Yeaw, X.; Murdoch, D.; Wijesekera, V.; Sedgwick, J.; Raffel, O.; Walters, D. // Heart, Lung & Circulation;2015 Supplement 3, Vol. 24, pS428 

    No abstract available.

  • Nanofilm coating shows excellent biocompatibility, safety.  // Advanced Materials & Processes;Jul2005, Vol. 163 Issue 7, p62 

    Reports that Vancouver, British Columbia-based developer of next-generation drug-eluting coatings that inhibit the rejection of implanted medical devices, MIV Therapeutics Inc., has successfully completed its pilot preclinical studies of hydroxy-apatite-coated stents in pig coronary arteries, in...

  • Over 1000 Patients Have Benefited from STENTYS Self-Apposing Technology.  // Biomedical Market Newsletter;9/26/2011, Vol. 21, p897 

    The article reports that the self-apposing technology for acute myocardial infarction (AMI) from STENTYS SAS has been implanted into more than 1000 patients across the globe. STENTYS chief executive officer (CEO) and co-founder Gonzague Issenmann has revealed the clear adoption pattern of the...

  • Prótesis metálica en paliación del cáncer avanzado del colon. Artifon, Everson L. A. // Revista Colombiana de Gastroenterología;Apr2011, Vol. 26 Issue 2, p132 

    The colonic stent placement is a new tool reaching two intends: creating a bridge to prepare the patient safely to the surgical procedure and/or definite palliation in those cases in which the clinical condition is not feasible. The cost-benefit analysis push advantages to the endoscopic assess...

  • Ventricular Fibrillation After Insertion of a Self-Expanding Metallic Stent for Malignant Dysphagia. Khan, Hamid Awad; Ahmad, Ishfaq; Ahmed, Waqar // American Journal of Gastroenterology;Mar2000, Vol. 95 Issue 3, p827 

    Reveals that since the first successful insertion of a metallic prosthesis in 1990, self-expanding metallic stents (SEMS) are increasingly being used for palliation of dysphagia caused by upper gastrointestinal malignancy. Advantages of metal stents; Information on a case of refractory...

  • Enteral stenting in 21 patients with malignant gastroduodenal obstruction. Tjun Tang; Allison, Mike; Dunkley, Irene; Roberts, Phil; Dickinson, Richard // Journal of the Royal Society of Medicine;Oct2003, Vol. 96 Issue 10, p494 

    Placement of an enteral stent is emerging as an effective alternative to surgery for symptomatic relief in patients with malignant gastric outflow and duodenal obstruction. We report experience in a series of patients who had the Wallstent enteral prosthesis inserted. 21 consecutive patients...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics