In vivo testing of an intra-annular aortic valve annuloplasty ring in a chronic calf model

Rankin, J. Scott; Conger, Jeff L.; Tuzun, Egemen; Winkler, Jo Anna; Harms, Kelly M.; Beavan, L. Alan; Fossum, Terry; Cohn, William E.
July 2012
European Journal of Cardio-Thoracic Surgery;Jul2012, Vol. 42 Issue 1, p149
Academic Journal
OBJECTIVE To increase applicability and stability of aortic valve repair, a three-dimensional aortic annuloplasty ring has been developed for intra-annular placement. The goal of this study was to test the safety of this device with in vivo implantation in the calf model. METHODS In 10 chronic calves, the HAART annuloplasty ring was sutured to the aortic valve annulus using cardiopulmonary bypass. The animals were recovered and followed for 1–2 months. Serial echocardiography was used to evaluate valve competence, and contrast aortograms and CT angiograms were obtained in selected animals. After completion of follow-up, each animal was euthanized, and aortic endoscopy was performed under water distension in five. Full autopsies with histologic examinations were performed. RESULTS All animals survived surgery. Two were euthanized in the first week for complications, and the remaining eight calves were followed uneventfully for the 1–2 months. Serial echocardiography showed completely competent valves in all but one animal, in which the ring was intentionally up-sized to test the sizing strategy. Contrast aortographic and CT angiographic findings were similar to the echocardiograms. Postmortem examination showed proper seating of all rings with endothelialization at 1–2 months. All valves demonstrated good leaflet coaptation and no abnormalities. CONCLUSIONS In vivo testing of a three-dimensional aortic annuloplasty ring in a chronic calf model proved to be very successful and safe. Using the sizing and implant strategies developed, human trials seem indicated.


Related Articles

  • A simplified surgical approach for aortic valve replacement after previous coronary artery bypass grafting Vistarini, Nicola; Aubert, Stéphane; Leprince, Pascal; Pavie, Alain // European Journal of Cardio-Thoracic Surgery;Aug2009, Vol. 36 Issue 2, p404 

    Abstract: Aortic valve replacement (AVR) in patients who have undergone previous coronary artery bypass grafting (CABG) is a challenging redo surgery. We undertook this study to evaluate the early and late outcomes of patients operated upon using a simplified surgical approach. Between January...

  • Abrupt formation of intracardiac thrombus during cardiopulmonary bypass with full heparinization -A case report-. Seong-Hyop Kim; Jae-Sung Ryu; Tae-Yop Kim; Tae-Gyoon Yoon; Woonseok Kang; Ji Eun Song // Korean Journal of Anesthesiology;Feb2012, Vol. 62 Issue 2, p175 

    Intracardiac thrombus during cardiopulmonary bypass (CPB) with full heparinization is very rare but fatal. A 60-year-old woman was scheduled for aortic and mitral valve repairs with a maze procedure for mixed aortic and mitral valvular heart disease with atrial fibrillation. Preoperative...

  • Immediate Closure of Paravalvular Leak After Transcatheter Aortic Valve Implantation. Saireddy, Ramakrishna; Subban, Vijayakumar; Lamana, Arvin; Clarke, Andrew; Scalia, Gregory M.; Raffel, Owen Christopher; Walters, Darren L. // Heart, Lung & Circulation;Nov2014, Vol. 23 Issue 11, pe251 

    No abstract available.

  • Preliminary feasibility and hemodynamic performance of a newly-developed self-expanding bioprosthesis and 16-F delivery system in transcatheter aortic valve implantation in sheep Cai, Jing; Sheng, Yanhui; Zhang, Shijiang; Sun, Wei; Yang, Rong; Miao, Liping; Kong, Xiangqing // Journal of Biomedical Research;May2012, Vol. 26 Issue 3, p211 

    Abstract: We sought to evaluate the feasibility and hemodynamic performance of a new self-expanding bioprosthesis and 16-F delivery system in sheep. A 23-mm new self-expanding aortic bioprosthesis was implanted in sheep (n = 10) with a 16-F catheter via the right common carotid artery. Each...

  • First registry results from the newly approved ACURATE TAâ„¢ TAVI system. Kempfert, Jörg; Holzhey, David; Hofmann, Steffen; Girdauskas, Evaldas; Treede, Hendrik; Schröfel, Holger; Thielmann, Matthias; Walther, Thomas // European Journal of Cardio-Thoracic Surgery;Jul2015, Vol. 48 Issue 1, p137 

    OBJECTIVES: The novel ACURATE TATM transcatheter aortic valve (Symetis, Ecublens, Switzerland) is composed of a self-expanding nitinol stent covered by an anti-paravalvular leak skirt designed for transapical implantation. Since Conformite Europeenne (CE)-mark approval, the first 250 patients...

  • Right ventricular function after aortic valve replacement: a pilot study comparing surgical and transcatheter procedures using 3D echocardiography. Keyl, Cornelius; Schneider, Jens; Beyersdorf, Friedhelm; Ruile, Philipp; Siepe, Matthias; Pioch, Katja; Schneider, Rebecca; Jander, Nikolaus // European Journal of Cardio-Thoracic Surgery;Mar2016, Vol. 49 Issue 3, p966 

    OBJECTIVES: Previous studies have found that standard echocardiographic measures of right ventricular (RV) function were impaired after surgical replacement of the aortic valve (SAVR), but not after transcatheter aortic valve implantation (TAVI). We used 3D echocardiography to gain further...

  • Accessory aortic-valve tissue as a cause of severe aortic regurgitation: intra-operative finding. Scandura, Salvatore; Cammalleri, Valeria; Meduri, Rocco; Tamburino, Corrado // European Journal of Cardio-Thoracic Surgery;Feb2012, Vol. 41 Issue 2, p452 

    The article presents a case study of a 61-year-old man who underwent aortic-valve (AV) replacement for severe aortic regurgitation (AR).

  • Aortic valve replacement with the Toronto SPV: long-term clinical and hemodynamic results. Dellgren, Göran; Feindel, Christopher M.; Bos, Joanne; Ivanov, Joan; David, Tirone E. // European Journal of Cardio-Thoracic Surgery;Apr2002, Vol. 21 Issue 4, p698 

    Objective: Long-term durability and hemodynamics of stentless valves are unknown. Therefore, this study was undertaken to evaluate long-term clinical and echocardiographic outcome after aortic valve replacement with the Toronto stentless porcine valve (SPV) bioprosthesis at our institution....

  • Serious about making history. Ratcliffe, Lucy // New Zealand Doctor;10/8/2008, p8 

    The article reports that the September 10, 2008 issue of "New Zealand Doctor" incorrectly reported that two cardiologists of Waikato Hospital were the first in the Southern Hemisphere to perform a transcatheter aortic valve implant procedure using the CoreValve device. The magazine received an...


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics