TITLE

A comparison of extraction chromatography TEVA resin and MRT AnaLig Tc-02 methods for Tc determination

AUTHOR(S)
Paučová, Veronika; Drábová, Veronika; Strišovská, Jana; Balogh, Szabolcs
PUB. DATE
July 2012
SOURCE
Journal of Radioanalytical & Nuclear Chemistry;Jul2012, Vol. 293 Issue 1, p309
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Two commercial products-molecular recognition technology (MRT) product AnaLigTc-02 gel and extraction chromatography TEVA resin were successfully tested for the separation of Tc. The results obtained for both procedures were compared in terms of activities and recoveries. The demonstrated linear model clearly proves that the residua fulfill the Gaussian model, without any autocorrelation and trend for NPL Alpha-Beta high 2003 intercomparison reference sample.
ACCESSION #
76447079

 

Related Articles

  • Validation of Sr separation method using molecular recognition product AnaLig Sr01 gel and extraction chromatography Sr resin. Drábová, Veronika; Strišovská, Jana; Dvorská, Lívia; Kuruc, Jozef // Journal of Radioanalytical & Nuclear Chemistry;Jun2012, Vol. 292 Issue 3, p1141 

    Two separation techniques for strontium determination using AnaLig Sr01 molecular recognition technology and extraction chromatography Sr resin were tested. The methods performance was investigated by analysis of NPL (High Alpha-Beta 2003) intercomparison sample. The results obtained for both...

  • Radiochemical separation of 67Ga from Zn and Cu using the adsorbent resin Amberlite XAD-7. Aardaneh, K.; Shirazi, B. // Journal of Radioanalytical & Nuclear Chemistry;Jul2005, Vol. 265 Issue 1, p47 

    A column chromatography was developed using a nonionic, polar adsorbent resin Amberlite XAD-7 for routine radiochemical separation of 67Ga from Zn and Cu. 7M HCl was found to be the optimum concentration for adsorption of 67Ga and elution of both Zn and Cu. Distilled water was used for elution...

  • The selective separation of Pu isotopes using molecular recognition technology product AnaLig Pu02 gel and extraction chromatography TRU resin. Dulanská, Silvia; Remenec, Boris; Mátel, Ľubomír; Galanda, Dušan // Journal of Radioanalytical & Nuclear Chemistry;Mar2011, Vol. 287 Issue 3, p841 

    Two separation techniques for plutonium determination using IBCS AnaLig Pu02 molecular recognition technology product (MRT) and extraction chromatography TRU resin (Eichrom Industries) to effectively and selectively separate and recover plutonium were tested. The performance of the methods was...

  • Polyamide Resin for Chromatography Passes Appraisal.  // China Chemical Reporter;1/26/2006, Vol. 17 Issue 3, p14 

    The article reports on the approval of a project based in the development of polyamide resin for chromatography by the Science and Technology Department of Sinopec. The project will jointly undertaken by Sinopec Baling Petrochemical Company Ltd. Technology Center and Sinopec Polyamide Technology...

  • General.  // LC-GC Europe;May2004 Applications, Vol. 17, p33 

    This article presents information on products related to chromatography. Available from Dionex Corp. is an application note describing the procedures and results of cleaning and eluting XAD-2 resin using ASE. The application uses the company's Dionex ASE 300 accelerated extractor with solvent...

  • OBRONY PRAC DOKTORSKICH.  // Polimery;2012, Vol. 57 Issue 10, p759 

    No abstract available.

  • The studies on absorption behavior of calix[4]-bis-crown-6 chromatographic resin and its application to the separation of HLW. Hao, Xiaojuan; Tan, Shuping; Deng, Weiqin // Journal of Radioanalytical & Nuclear Chemistry;Jun2012, Vol. 292 Issue 3, p1291 

    In this paper, to separation Cs(I) effectively from HLW, a kind of chromatographic rein was synthesized through immobiling calix[4]-bis-crown-6 on the macroporous polystyrene -divinylbenzene polymeric material. The synthesized chromatographic resin showed high ability to absorb Cs(I). While the...

  • Evaluation study on properties of isohexyl-BTP/SiO-P resin for direct separation of trivalent minor actinides from HLLW. Liu, Ruiqin; Wei, Yuezhou; Xu, Yuanlai; Usuda, Shigekazu; Kim, Seongyun; Yamazaki, Hiromichi; Ishii, Keizo // Journal of Radioanalytical & Nuclear Chemistry;May2012, Vol. 292 Issue 2, p537 

    In order to develop a direct separation process for trivalent minor actinides from fission products in high level liquid waste (HLLW) by extraction chromatography, a novel macroporous silica-based 2,6-bis(5,6-di isohexyl)-1,2,4-triazin-3-yl)pyridine resin ( isohexyl-BTP/SiO-P resin) was...

  • Comparison of Binding Capacity and Affinity of Monoclonal Antibody towards Different Affinity Resins using High-throughput Chromatography Method. Pakiman, N.; Isa, N. H.; Hassan, M. A. Abol; Walter, J. K.; Abdullah, N. // Journal of Applied Sciences;2012, Vol. 12 Issue 11, p1136 

    Protein-A Affinity chromatography is the widely used key method for purification of monoclonal antibodies. Selection of a most suitable affinity resin based on binding capacity and affinity is typically performed prior to optimization. Development of high-throughput chromatography method in...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library