TITLE

Development of Parallel and Fan-Shaped Beam Mixed-Projection Optical Tomography

AUTHOR(S)
Muji, Siti Zarina Mohd.; Rahim, Ruzairi Abdul; Rahiman, Mohd Hafiz Fazalul; Yunus, Yusry; Zakaria, Zulkarnay; Ayob, Nor Muzakkir Nor
PUB. DATE
May 2012
SOURCE
Sensors & Transducers (1726-5479);May2012, Vol. 140 Issue 5, p36
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Parallel and fan shaped beam are two common projections that had been used widely in optical tomography system. These projections never have been merged before in the process of tomography area. In this paper, some enhancement has been made by combining these two modalities in order to solve the ambiguity that arises in the parallel beam projection.
ACCESSION #
76359620

 

Related Articles

  • A Study on Optical Sensors Orientation for Tomography System Development. Shaib, M. Fadzli B. Abdul; Rahim, Ruzairi Abdul; Muji, Siti Zarina M.; Leow Pei Ling; Jamil, M. Mahadi Abdul // Sensors & Transducers (1726-5479);May2012, Vol. 140 Issue 5, p45 

    This paper describes the investigation of optical sensors performance towards the development of optical tomography system. The orientation of the transmitters has been set from 0° until 180° and then the receiver's responses were analyzed. Hence, sensors capabilities were tested further...

  • An optical transduction chain for the AURIGA detector. Conti, L.; Marin, F.; De Rosa, M.; Prodi, G. A.; Taffarello, L.; Zendri, J. P.; Cerdonio, M.; Vitale, S. // AIP Conference Proceedings;2000, Vol. 523 Issue 1, p261 

    Focuses on optical transduction chain from AURIGA detector. Data on the sensitivity level of the detector; Attainment of quantum limited laser power noise through active stabilization; Isolation of the cavity from mechanical disturbances by double stage cantilever system.

  • Optical Tomography System: Charge-coupled Device Linear Image Sensors. Idroas, M.; Rahim, R. Abdul; Rahiman, M. H. Fazalul; Green, R. G.; Ibrahim, M. N. // Sensors & Transducers (1726-5479);Sep2010, Vol. 120 Issue 9, p62 

    This paper discussed an optical tomography system based on charge-coupled device (CCD) linear image sensors. The developed system consists of a lighting system, a measurement section and a data acquisition system. Four CCD linear image sensors are configured around a flow pipe with an...

  • Superresolution in Diffuse Optical Tomography. Kalintsev, A. G.; Kalintseva, N. A.; Kravtsenyuk, O. V.; Lyubimov, V. V. // Optics & Spectroscopy;Jul2005, Vol. 99 Issue 1, p152 

    The possibility of applying image reconstruction methods used in optics to improve the resolution of the photon average trajectories method of diffuse optical tomography is demonstrated. The limit resolution determined by Nyquist’s consequence of the Kotel’nikov–Shannon...

  • Use of polymer-based sensors for monitoring the static and dynamic response of a cantilever composite beam. Kuang, K. S. C.; Quek, S. T.; Cantwell, W. J. // Journal of Materials Science;Jun2004, Vol. 39 Issue 11, p3839 

    Focuses on the use of polymer-based sensors for monitoring the static and dynamic response of a cantilever composite beam. Experimental set-up used in the study; Optical properties of the polymeric materials.

  • Array detector for the atomic force microscope. Scha¨ffer, Tilman E.; Richter, Michael; Viani, Mario B. // Applied Physics Letters;6/12/2000, Vol. 76 Issue 24 

    We present a method for measuring the deflection of the optical beam in an atomic force microscope (AFM) that yields an increased signal-to-noise ratio, compared to the conventional two-segment detection. This increase is achieved by distributing the optical power from the beam across an array...

  • Chemical-vapor sensor uses holographic interferometry. Overton, Gail // Laser Focus World;Sep2005, Vol. 41 Issue 9, p13 

    Reports on the development of an interferometric approach to chemical vapor sensing using dynamic holography to interrogate an array of chemically selective polymers by scientists at the University of Colorado in Boulder, Colorado. Interrogation of a large array of transducer elements in...

  • Resolution Enhancement in Surface Plasmon Resonance Sensor Based on Waveguide Coupled Mode by Combining a Bimetallic Approach. Kyeong-Seok Lee; Ju Myeong Son; Dae-Yong Jeong; Taek Sung Lee; Won Mok Kim // Sensors (14248220);2010, Vol. 10 Issue 12, p11390 

    In this study, we present and demonstrate a new route to a great enhancement in resolution of surface plasmon resonance sensors. Basically, our approach combines a waveguide coupled plasmonic mode and a kind of Au/Ag bimetallic enhancement concept. Theoretical modeling was carried out by solving...

  • Composite video generation for an OMA vidicon detector. Cascio, Horace E.; Balaban, Robert S.; Smith, Paul D. // Review of Scientific Instruments;Apr1985, Vol. 56 Issue 4, p535 

    A commercial vidicon detector, designed for scientific purposes with user-controlled target scanning, was modified to produce a computer-controlled optional composite video signal permitting rapid acquisition of two-dimensional data. A video preamplifier and a processing amplifier were...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics