TITLE

An improved quasistatic line-shape theory: The effects of molecular motion on the line wings

AUTHOR(S)
Ma, Q.; Tipping, R. H.
PUB. DATE
April 1994
SOURCE
Journal of Chemical Physics;4/15/1994, Vol. 100 Issue 8, p5567
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A theory is presented for the modification of the line-shape functions and absorption coefficient due to the breakdown of the quasistatic approximation. This breakdown arises from the effects of molecular motion and increases the absorption in the near wings. Numerical calculations for the high-frequency wing of the ν3 band of CO2 broadened by Ar are reported and it is shown that these effects are significant near the bandhead. The importance of such corrections in other spectral regions and for other systems is discussed briefly.
ACCESSION #
7626347

 

Related Articles

  • Apparent absorption method for solving planar problems of interfacial cracking. Kardovskiĭ, I.; Pryakhina, O. // Doklady Physics;Oct2006, Vol. 51 Issue 10, p574 

    The article discusses the method to derive equation for the Apparent absorption method for solving planar problems of interfacial cracking. The method gives an effective approach to solving integral equations of dynamical problems by the method of apparent absorption. The idea is to transform...

  • Parameterization of the Mie Extinction and Absorption coefficients for water clouds.  // Journal of the Atmospheric Sciences;5/1/2000, Vol. 57 Issue 9, p1311 

    Presents information on a study which addressed the parameterization of the Mie extinction and absorption coefficients for water clouds. Parameterization of absorption efficiency; Methodology of the study; Results and discussion.

  • Absorption of coefficient of 4H silicon carbide from 3900 to 3250... Sridhara, S.G.; Devaty, R.P.; Choyke, W.J. // Journal of Applied Physics;9/1/1998, Vol. 84 Issue 5, p2963 

    Focuses on the absorption coefficient of four hydrogen silicon carbide at room temperature. Range of the wave lengths; Correlation of the shift in the band gap with the temperature; Presentation of an estimate of thew absorption coefficient of 4hydrogen silicon carbide at two degrees kelvin.

  • Towards a voltage tunable two-color quantum-well infrared photodetector. Majumdar, Amlan; Choi, K. K.; Rokhinson, L. P.; Tsui, D. C. // Applied Physics Letters;1/28/2002, Vol. 80 Issue 4, p538 

    Two-color quantum-well infrared photodetectors (QWIPs), based on electron transfer between coupled QWs, suffer from the presence of the shorter wavelength peak at all bias voltages V[sub b]. We investigate this problem by studying the bias dependence of absorption coefficient α and...

  • Radiography of nonaxisymmetric objects: An onion-peeling inversion method. Schwierz-Iosefzon, T.; Notea, A.; Deutsch, M. // Applied Physics Letters;9/9/2002, Vol. 81 Issue 11, p2121 

    An onion-peeling method for obtaining the linear attenuation coefficient distribution within a body from a single radiographic projection is presented. Unlike previous methods, which are applicable only to axi- or centrosymmetric objects, ours requires only mirror symmetry relative to the plane...

  • Ultrasonic Attenuation as Influenced by Elongated Grains. Ahmed, S.; Thompson, R. B.; Panetta, P. D. // AIP Conference Proceedings;2003, Vol. 657 Issue 1, p109 

    Reliable nondestructive evaluation of structural/machine components fabricated from polycrystalline materials require the knowledge of attenuation and dispersion of an ultrasonic wave propagating through such microscopically inhomogeneous medium. Expected propagation characteristics of...

  • An automatic classification technique for attenuation correction in positron emission tomography. Bettinardi, V.; Pagani, E.; Gilardi, M. C.; Landoni, C.; Riddell, C.; Rizzo, G.; Castiglioni, I.; Belluzzo, D.; Lucignani, G.; Schubert, S.; Fazio, F. // European Journal of Nuclear Medicine;1999, Vol. 26 Issue 5, p447 

    Abstract. In this paper a clustering technique is proposed for attenuation correction (AC) in positron emission tomography (PET). The method is unsupervised and adaptive with respect to counting statistics in the transmission (TR) images. The technique allows the classification of pre- or...

  • Cardiac single-photon emission tomography: is attenuation correction enough? Hutton, Brian F. // European Journal of Nuclear Medicine;1997, Vol. 24 Issue 7, p713 

    Consider the possible solutions to improve cardiac single-photon emission tomography. Application of attenuation correction to reduce the uncertainty of the procedure; Compensation for the distance-dependent resolution; Reasons for the reduced perfusion of the procedure.

  • Reply. Shiga, Tohru; Kubo, Naoki; Tsukamoto, Eriko; Tamaki, Nagara // European Journal of Nuclear Medicine & Molecular Imaging;2002, Vol. 29 Issue 7, p969 

    Comments on Zaidi and Montandon's comments the use of attenuation coefficient in combined attenuation and scatter corrections for quantitative brain SPET. Aim of the study; Authors' explanation on several issues in the article misinterpreted by Zaidi and Montando.

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics