TITLE

Field ion microscopic studies of the CO oxidation on platinum: Bistability and oscillations

AUTHOR(S)
Gorodetskii, V.; Drachsel, W.; Ehsasi, M.; Block, J. H.
PUB. DATE
May 1994
SOURCE
Journal of Chemical Physics;5/1/1994, Vol. 100 Issue 9, p6915
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The oscillating CO oxidation is investigated on a Pt-field emitter tip by using the field ion mode of surface imaging of Oad sites with O2 as imaging gas. Based on data of the titration reactions [V. Gorodetskii, W. Drachsel, and J. H. Block, J. Chem. Phys. 100, C. E. UPDATE (1994)], external control parameters for the regions of bistability and of self-sustained isothermal oscillations could be found. On a field emitter tip, oscillations can be generated in a rather large parameter space. The anticlockwise hysteresis of O+2 ion currents in temperature cycles occurs in agreement with results on single crystal planes. Unexpected regular oscillation sequences could occasionally be obtained on the small surface areas of a field emitter tip and measured as function of the CO partial pressure and of the temperature. Different stages within oscillating cycles were documented by field ion images. Oscillations of total ion currents are correlated with variations in the spatial brightness of field ion images. In the manifold of single crystal planes of a field emitter {331} planes around the {011} regions are starting points for oscillations which mainly proceed along [100] vicinals. This excludes the {111} regions from autonomous oscillations. With slightly increased CO partial pressures fast local oscillations at a few hundred surface sites of the Pt(001) plane display short-living CO islands of 40 to 50 Ã… diameter. Temporal oscillations of the total O+2 ion current are mainly caused by surface plane specific spatial oscillations. The synchronization is achieved by diffusion reaction fronts rather than by gas phase synchronization.
ACCESSION #
7618754

 

Related Articles

  • Elimination of residual image distortion in the stigmatic ion microscope. Bernius, Mark T.; Ling, Yong-Chien; Morrison, George H. // Journal of Applied Physics;3/1/1987, Vol. 61 Issue 5, p1677 

    Presents information on a study which incorporated a combination of electrostatic octupole stigmator and cosine deflector into the secondary ion-optical lattice of the stigmatic ion microscope. Apparatus and methods; Results of digital image superpositioning; Numerical evaluations of image...

  • Incorporation of accelerated low-energy (50–500 eV) In+ ions in Si(100) films during growth by molecular-beam epitaxy. Hasan, M. A.; Knall, J.; Barnett, S. A.; Sundgren, J.-E.; Markert, L. C.; Rockett, A.; Greene, J. E. // Journal of Applied Physics;1/1/1989, Vol. 65 Issue 1, p172 

    Presents a study that used a single-grid broad-beam ion source for low-energy accelerated indium (In)[sub+] ion beam doping during growth of silicon layers by molecular-beam epitaxy. Indium incorporation behavior; Use of secondary ion mass spectroscopy; Determination of the abrupt doping profiles.

  • Field ion microscopy (FIM) and atom probe (AP) investigations of FeNdB and related permanent magnets. Hütten, A.; Haasen, P. // Journal of Applied Physics;4/15/1987, Vol. 61 Issue 8, p3769 

    Examines the local chemical compositions of rapidly solidified FeNdB magnets by using a field ion microscope combined with an atom probe. Basis of the magnetic performance of the sintered and the melt-spun FeNdB; Conditions which improve the magnetic values of FeNdB; Field ion micrograph of the...

  • Role of tip structure in scanning tunneling microscopy. Kuk, Y.; Silverman, P. J. // Applied Physics Letters;6/9/1986, Vol. 48 Issue 23, p1597 

    An ultrahigh vacuum scanning tunneling microscope (STM) equipped with a field ion microscope (FIM) has been built. By using the FIM image, a tungsten tip was tailored for high STM resolution in a scan of the Au(001) surface. The measured corrugation depth of the (1×5) rows was found to be a...

  • Twelve-ton shrimp may reveal cosmos secrets. Kren, Lawrence // Machine Design;05/06/99, Vol. 71 Issue 9, p52 

    Offers a look at the sensitive-high-resolution-ion-microprobe (Shrimp) instrument. Function of the instrument; Information on its ion-mass spectrometer; Application of the instrument.

  • A miniature electron-beam evaporator for an ultrahigh-vacuum atom-probe field-ion microscope. Lin, X. W.; Hu, J. G.; Seidman, D. N.; Morikawa, H. // Review of Scientific Instruments;Dec1990, Vol. 61 Issue 12, p3745 

    A miniature electron-beam evaporator (MEBE) has been fabricated and adapted to our ultrahigh-vacuum atom-probe field-ion microscope (APFIM). The MEBE allows for in situ vapor deposition-under ultrahigh-vacuum conditions ( < 4 × 10-10 Torr)-of a wide range of elements, on the surface of an...

  • Age of volcanic rocks and syndepositional iron formations, Marquette Range Supergroup: implications for the tectonic setting of Paleoproterozoic iron formations of the Lake Superior region. Schneider, D A; Bickford, M E; Cannon, W F; Schulz, K J; Hamilton, M A // Canadian Journal of Earth Sciences;Jun2002, Vol. 39 Issue 6, p999 

    A rhyolite in the Hemlock Formation, a mostly bimodal submarine volcanic deposit that is laterally correlative with the Negaunee Iron-formation, yields a sensitive high-resolution ion microprobe (SHRIMP) U–Pb zircon age of 1874 ± 9 Ma, but also contains inherited Archean zircons as old...

  • Cryogenic sample stage for the Cameca IMS-3f ion microscope. Bernius, Mark T.; Chandra, Subhash; Morrison, George H. // Review of Scientific Instruments;Jul1985, Vol. 56 Issue 7, p1347 

    A simple and inexpensive cold stage developed for use with the Cameca IMS-3f ion microscope is described. It is easy to use, and temperatures near to that of liquid nitrogen are obtained. Data are presented showing the first analysis of frozen hydrated biological samples with the ion microscope.

  • A system for systematically preparing atom-probe field-ion-microscope specimens for the study of internal interfaces. Krakauer, B. W.; Hu, J. G.; Kuo, S.-M.; Mallick, R. L.; Seki, A.; Seidman, D. N.; Baker, J. P.; Loyd, R. J. // Review of Scientific Instruments;Nov90, Vol. 61 Issue 11, p3390 

    A versatile system has been designed and fabricated to prepare atom-probe field-ion-microscope (APFIM) specimens in a systematic manner, such that internal interfaces can be positioned in the tips of these wire specimens for subsequent analysis of their chemical composition. This system...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library