TITLE

ABB Prepares for 380-kV Breaker Launch

PUB. DATE
April 2012
SOURCE
Transmission & Distribution World Exclusive Insight;4/26/2012, p9
SOURCE TYPE
Trade Publication
DOC. TYPE
Article
ABSTRACT
The article cites ABB's preparation for the launch of the type 362PMG-B gang operated, dead tank gas circuit breaker during the third quarter of 2012. The 362PMG-B is described to be based on the design of the 362PMI-B independent pole operated breaker. The breaker is presented to offer a universal solution for users requiring three-phase tripping and closing functionality, and is referred as the first dead tank breaker equipped with high-energy BLG 1002 spring drive.
ACCESSION #
75649787

 

Related Articles

  • ABB finds the HVDC holy grail.  // Modern Power Systems;Dec2012, Vol. 32 Issue 12, p4 

    The article reports that ABB has finally designed and developed a practical high voltage high direct current (HVDC) breaker after years of research and testing. It states that the breaker resolves the technical problem in creating a disconnector-recloser that will enable fast operation with...

  • Breaker, Breaker. Winstanley, Gerard // Remodeling;May2012, Vol. 28 Issue 5, p27 

    The article offers information on Arc-fault circuit interrupters (AFCIs) which is designed to detect dangerous electrical conditions.

  • Process safety relays.  // Plant Engineering;May2011, Vol. 65 Issue 4, p47 

    The article presents information about the PSR-FSP2/2x1 and PSR-FSP/2X1 process safety relays.

  • ABB cracks DC current interrupt problem.  // Electronics Weekly;11/14/2012, Issue 2527, p5 

    The article reports on the development of a circuit breaker for high voltage direct current (HVDC) by ABB.

  • ABB to Supply Switchgear Technology for Smart Substations in China.  // Transmission & Distribution World Exclusive Insight;1/7/2016, p1 

    The article reports on the automation firm ABB to install disconnecting circuit breaker with Fiber Optic Current Sensor (FOCS) integrating substation functions such as circuit-breaking and current measurement in a single switchgear and mentions FOCS to replace conventional current transformers.

  • Rise of the breaker people. Sanford, Leonard // Modern Power Systems;Dec2012, Vol. 32 Issue 12, p8 

    The author discusses the new chapter of electrical engineering with the development of high voltage direct current (DC) circuit breaker (HVDC) by ABB. He mentions the importance of the viable DC breaker for transmission voltages due to its combined fast mechanics and power electronics. The...

  • Protect Against Faulty Grounds.  // PS: Preventive Maintenance Monthly;Jan2001, Issue 578, p56 

    Deals with the importance of ground fault circuit interrupter to prevent electric shock

  • ABB to develop 1200 kV AC CB.  // Modern Power Systems;May2012, Vol. 32 Issue 5, p8 

    The article reports on the plan of ABB to develop, design and manufacture a 1200 kilovolt circuit breaker.

  • Low-Voltage Breaker for Energy Management and Smart Grid Communications.  // Transmission & Distribution World Exclusive Insight;4/25/2013, p1 

    The article discusses the release of Emax 2, a low-voltage circuit breaker with integrated energy management functions, from ABB.