Introduction. In recent years the number of patients with complex congenital heart disease previously corrected in infancy who need a pulmonary valve replacement has increased dramatically. The ideal substitute remains a source of dispute. Nowadays, in the unit of cardiovascular surgery of the Hospital Ramon y Cajal in Spain, its being implanting in this position the bovine pericardium Carpentier-Edwards® prosthesis. The aim of the study its short and medium-term assessment. Material and methods. Between January 2004 and May of 2010, 42 patients have been operated for pulmonary valve replacement with pericardium prosthesis. The study was ambispective, being prospective in its last two years. Results. The median age of the patients was 20.96 years (interquartile 10.5 years). The mean number of surgeries prior to the pulmonary valve replacement was 1.9±0.9, being the mean time between the "corrective" surgery and the prosthetic implantation 17.2±7 years. The main indications for this surgery were: right ventricle dysfunction (45%), progressive dilation of the same ventricle (38%), ventricular arrhythmias (14%) and syncopes (3%). Two patients died in the immediate postoperative due to cardiological causes. The mean follow-up time has been 2.1±1.4 years (0.1-6.3). The 94.3 % of the surviving patients are in functional class I, according to the New York Health Association. The peak Doppler transprosthetic gradient determined by echocardiography was 18.5±17 mm Hg. In the echocardiograpic follow-up there have been neither degenerative changes nor any type of structural deterioration of the prosthesis. Conclusions. The bovine pericardium prosthesis in pulmonary position presents excellent results in the short and medium-term. However, it is necessary a longer follow-up to confirm our initial results regarding its durability and long-term haemodynamics.


Related Articles

  • Spontaneous closure of a left ventricle pseudoaneurysm following apical venting. Lopes, Ricardo; Almeida, Jorge; Silva, João Carlos; Almeida, Pedro Bernardo; Madureira, António J.; Ramos, Isabel; Pinho, Paulo; Maciel, Maria Júlia // European Journal of Echocardiography;Feb2011, Vol. 12 Issue 2, pE6 

    Cardiac surgery is the second most frequent aetiology of left ventricular pseudoaneurysm (LVP). Left ventricular apical venting is a recognized cause of LVP. Prompt surgical treatment is usually needed since there is a high risk of rupture and spontaneous closure is very rare. We describe a case...

  • Anesthetic Management of Hypoplastic Left Heart Syndrome. Dulian, Stephanie M. // International Student Journal of Nurse Anesthesia;Summer2009, Vol. 8 Issue 2, p14 

    Hypoplastic left heart syndrome (HLHS) and other complex single ventricles refer to congenital abnormalities of the left-sided heart structures including the left ventricle, mitral valve and aortic arch. These changes result in a univentricular heart and is unvaryingly fatal in infancy without...

  • Fixing heart defects without surgery. Teresko, John // Industry Week/IW;03/16/98, Vol. 247 Issue 6, p18 

    Focuses on a breakthrough in heart surgery wherein doctors can close the holes in the wall between the two atria of the heart without opening the thorax when inserting prosthesis. Brief description of the procedure; Components of the prosthesis; Information on what the approach offers.

  • Surgery for prosthetic valve obstruction. A single center study of 136 patients Roudaut, Raymond; Roques, Xavier; Lafitte, Stéphane; Choukroun, Emmanuel; Laborde, Nadine; Madona, Francesco; Deville, Claude; Baudet, Eugène // European Journal of Cardio-Thoracic Surgery;Dec2003, Vol. 24 Issue 6, p868 

    Objectives: Prosthetic heart valve obstruction (PHVO) is a potentially fatal complication of heart valve replacement with mechanical substitute mainly due to thrombosis. The purpose of this report is to present a single-center experience of 136 consecutive patients operated on between 1978 and...

  • Left and right ventricular function in aortic stenosis patients 8 weeks post-transcatheter aortic valve implantation or surgical aortic valve replacement. Forsberg, Lena M.; Tamás, Éva; Vánky, Farkas; Nielsen, Niels Erik; Engvall, Jan; Nylander, Eva // European Journal of Echocardiography;2011, Vol. 12 Issue 8, p603 

    Aims Knowledge of longitudinal left and right ventricular (LV and RV) function after transcatheter aortic valve implantation (TAVI) is scarce. We hypothesized that the longitudinal systolic biventricular function in aortic stenosis (AS) patients is affected differently by TAVI and surgical...

  • Pregnancy in patients with prosthetic heart valves. Oakley, Celia // British Medical Journal (Clinical Research Edition);5/28/1983, Vol. 286 Issue 6379, p1680 

    Focuses on the effects of pregnancy on patients with prosthetic heart valves. Increase in the risk of thromboembolism; Effects in the usage of coumarin anticoagulants in pregnancy; Safeness of heparin.

  • In good health and young at heart. Lovell, Ivy // British Journal of Cardiac Nursing;Jul2014, Vol. 9 Issue 7, p361 

    A personal narrative is presented which explores the author's experience of being diagnosed of heart valve disease despite being healthy all her life and surviving after undergoing a transcatheter aortic valve implantation (TAVI) procedure.

  • Transapical perfusion for peri-arrest salvage during transcutaneous aortic valve implantation. Göbölös, L.; Tsang, G. M.; Curzen, N.; Calver, A. L.; Ohri, S. K. // Perfusion;Nov2015, Vol. 30 Issue 8, p650 

    An 80-year-old man developed severe haemodynamic instability during a transapical aortic valve implantation. He was not suitable for a conventional surgical approach due to comorbidities and patent aortocoronary bypass grafts also limited further stabilizing actions. As a bail-out procedure, we...

  • Artificial aortic valve dysfunction due to pannus and thrombus - different methods of cardiac surgical management. Ostrowski, Stanisław; Marcinkiewicz, Anna; Kośmider, Anna; Walczak, Andrzej; Zwolinski, Radoslaw; Jaszewski, Ryszard // Polish Journal of Thoracic & Cardiovascular Surgery;2015, Vol. 12 Issue 3, p199 

    Introduction: Approximately 60 000 prosthetic valves are implanted annually in the USA. The risk of prosthesis dysfunction ranges from 0.1% to 4% per year. Prosthesis valve dysfunction is usually caused by a thrombus obstructing the prosthetic discs. However, 10% of prosthetic valves are...