TITLE

An Evaporator's Temperature Difference

AUTHOR(S)
Marchese, Joe
PUB. DATE
March 2012
SOURCE
Air Conditioning, Heating & Refrigeration News;3/5/2012, Vol. 245 Issue 10, p30
SOURCE TYPE
Trade Publication
DOC. TYPE
Article
ABSTRACT
The author discusses the temperature difference of an evaporator referring to the difference between the saturation temperature of the refrigerant inside the coil and its entering air temperature.
ACCESSION #
73791576

 

Related Articles

  • Sizing Walk-in Coolers And Freezers.  // Air Conditioning, Heating & Refrigeration News;6/3/2002, Vol. 216 Issue 5, p27 

    Focuses on the load calculations among walk-in coolers and freezers. Consideration of the maximum ambient temperature; Basis of load estimates; Comprehension of the load application.

  • Temp Controls Key In Cooler Repairs. Marchese, Joe // Air Conditioning, Heating & Refrigeration News;3/3/2003, Vol. 218 Issue 9, p9 

    Discusses the importance of temperature control in repairing reach-in- coolers. Capacity to sense the temperature of the evaporator coil; Effectivity in controlling the case temperature; Adjustability of the cutout values in colder and warmer case temperature.

  • Using a Low-Pressure Control to Maintain Temps. Marchese, Joe // Air Conditioning Heating & Refrigeration News;02/05/2001, Vol. 212 Issue 6, p13 

    Explores the application of low pressure control to refrigeration systems. Mechanism of low pressure control; Determination of coil temperature; Procedures for setting the differential pressure.

  • the HOTLINE. Kramer, Dan // Air Conditioning Heating & Refrigeration News;1/12/2004, Vol. 221 Issue 2, p38 

    Presents question and answer advisory related to refrigeration and heating. Way to solve the problem on to replace the mechanical system with new equipment; Heat rejection; Measurement of the air temperature.

  • Compressor Engineering and Refrigeration conference particpants.  // Air Conditioning, Heating & Refrigeration News;10/07/96, Vol. 199 Issue 6, p9 

    Presents a photograph of some of the participants in the Compressor Engineering and Refrigeration conference at Purdue University in West Lafayette, Indiana.

  • Water coolers evolve to meet changing needs. Hird, Mark // PM Engineer;Apr95, Vol. 1 Issue 3, p38 

    Focuses on the issues faced by manufacturers about the changes in the water cooling industry. Refrigerant issues; Lead issues; Challenges of providing products ha comply with the requirements of the Americans with Disabilities Act (ADA); National Sanitation Foundation Standard 61 as another...

  • The Hot Pull Down. Marchese, Joe // Air Conditioning, Heating & Refrigeration News;12/5/2011, Vol. 244 Issue 14, p19 

    The article discusses the use of measuring the superheat value of the refrigerant in installing refrigeration system with the use of thermostatic expansion value.

  • Pressures, States, And Conditions. Tomczyk, John // Air Conditioning Heating & Refrigeration News;8/1/2005, Vol. 225 Issue 14, p9 

    Describes the components of the basic refrigeration system. Identification of the refrigeration compressor as a vapor pump; Percentage of the saturated liquid point; Usability of the evaporator outlet temperature for evaporator superheat calculations.

  • IIAR Is Helping Smaller Plants Using Ammonia.  // ASHRAE Journal;Apr2004, Vol. 46 Issue 4, p16 

    Focuses on the use of ammonia refrigeration which is actively promoted by the International Institute of Ammonia Refrigeration (IIAR) in Orlando, Florida. Release of the IIAR Ammonia Refrigeration Management program; Provision of voluntary guidance to safely manage and operate ammonia systems...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.