TITLE

Blood salvage with a continuous autotransfusion system compared with a haemofiltration system

AUTHOR(S)
Nitescu, N; Bengtsson, A; Bengtson, JP
PUB. DATE
September 2002
SOURCE
Perfusion;Sep2002, Vol. 17 Issue 5, p357
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Red blood cells may be destroyed by autotransfusion processing during intraoperative salvage. The aim of the present study was to evaluate the blood component recovery rate of techniques built on either continuous centrifugation and washing, or haemofiltration (HF). Methods: Two different methods used in blood salvage - red cell salvage with continuous processing with centrifugation and saline washing (Continuous Auto Transfusion System, CATS) and whole blood recirculation through a 30000-Da filter, i.e., HF - were compared in a randomized laboratory study using donor whole blood activated by cobra venom factor. The recovery of red blood cells, haemoglobin, free haemoglobin, leucocytes, platelets, albumin, total protein and potassium was measured. Results: The recovery of red cells was 86% with CATS and 76% with HF. HF had a significantly higher recovery of leucocytes (CATS 20%, HF 63%), platelets (CATS 4%, HF 37%), albumin (CATS 0.2%, HF 70%), total protein (CATS 1.3%, HF 71%) and potassium (CATS 2%, HF 17%). Less than 1% haemolysis was obtained in processed blood from both groups. Conclusion: Both methods caused little destruction of the red blood cells during processing. There was a larger reinfusion of leucocytes, platelets, albumin, total protein and extracellular potassium when HF was used compared with the 'CATS' method.
ACCESSION #
7287669

 

Related Articles

  • Clinical, haematological and biochemical responses of sheep undergoing autologous blood transfusion. Santos Sousa, Rejane; Ferreira Chaves, Dowglish; Alves Barrêto-Júnior, Raimundo; Freitas Sousa, Isadora Karolina; Sousa Soares, Herbert; Oliveira Barros, Isabella; Hamad Minervino, Antonio Humberto; Ortolani, Enrico Lippi // BMC Veterinary Research;2012, Vol. 8 Issue 1, p61 

    Background: This study aimed to evaluate the clinical, haematological and biochemical responses to autologous blood transfusion and the feasibility of this practice in sheep. Thus, we used eight male, 8 months old sheep, weighing on average 30 kg, from which 15 mL/kg of whole blood was collected...

  • Application of the continuous autotransfusion system (CATS) to prevent transfusion-related hyperkalemia following hyperkalemic cardiac arrest in an infant - A case report -. Hye-Min Sohn; Yong-Hee Park; Hyo-Jin Byon; Jin-Tae Kim; Hee-Soo Kim; Chong Sung Kim // Korean Journal of Anesthesiology;Mar2012, Vol. 62 Issue 3, p281 

    Transfusion-induced hyperkalemia can lead to cardiac arrest, especially when the patient rapidly receives a large amount of red blood cells (RBCs), previously stored for a long period of time, irradiated or both. We report on a case of application of the Continuous AutoTransfusion System (CATS)...

  • More surgeons advocate autologous transfusions.  // Nutrition Health Review: The Consumer's Medical Journal;Fall90, Issue 56, p8 

    Reports that an increasing number of surgeons are choosing to use autologous transfusion or the use of blood from the patient during surgical procedures. Safety profile of the transfusion method.

  • Salvaging blood from the chest. Carroll, Patricia; Begany, Timothy // RN;Sep96, Vol. 59 Issue 9, p32 

    Discusses the scope of chest drain autotransfusion. Importance of transfusing autologous blood with a chest drainage; Indications and contraindications; Advantage of the unbroken circuit method; Steps of setting up the intermittent approach; Worksheet on blood loss; Caution on continuous and to...

  • Towards the identification of autologous blood transfusions through capillary electrophoresis. Harrison, Christopher; Fang, Jack; Walthall, Kimberly; Green, Chelsea; Porobic, Vukica // Analytical & Bioanalytical Chemistry;Jan2014, Vol. 406 Issue 3, p679 

    The use of autologous blood transfusions by endurance athletes has remained one of the most difficult doping practices to detect. The implementation of the Athlete's Biological Passport by some sporting bodies has proved to be effective; however, the analysis relies on the long-term monitoring...

  • Autologous blood transfusion. The only solution in relation to blood safety. Jain, S. // Asian Journal of Transfusion Science;Jul-Dec2007, Vol. 1 Issue 2, p99 

    Introduction: Autologous blood transfusion means, Collecting pt. Own blood for himself during surgery. Very old concept 100 yr old Not very popular before 1968 Klebanoff devised easy method for recovery M. Orr and R. Gilchar established washing technique. Separation of plasma, cell washing,...

  • Impact on early and late mortality after blood transfusion in coronary artery bypass graft surgery. Alceu dos Santos, Antonio; Gonçalves Sousa, Alexandre; de Souza Thomé, Hugo Oliveira; Longo Machado, Roberta; Ferrari Piotto, Raquel // Brazilian Journal of Cardiovascular Surgery;jan-mar2013, Vol. 28 Issue 1, p1 

    Objective: To assess the 30-day and 1-year mortality associated to the red blood cell transfusion after coronary artery bypass grafting surgery. This procedure has been questioned by the international medical community, but it is still widely used in cardiac surgery. Therefore, it is needed more...

  • Evaluating the 'next generation' of cell salvage - will it make a difference? Yarham, Gemma; Clements, Ann; Oliver, Martin; Morris, Christopher; Cumberland, Tom; Bryan, Megan; Jekler, Sasa; Johns, Kathy; Mulholland, John // Perfusion;Jul2011, Vol. 26 Issue 4, p263 

    Introduction: Donor blood supplies are diminishing, becoming more costly and these transfusions lead to higher mortality in cardiac patients. The transfusion risks and the literature highlight the need for an alternative similar to cell salvage to be routinely considered. The Xtra is the first...

  • Blood Level Sensor Based on Digital Video Analyzer for Autotransfusion Devices. Selyanko, I.; Medvedev, E.; Epishin, E. // Biomedical Engineering;Sep2014, Vol. 48 Issue 3, p116 

    Results of studies of an original blood level sensor designed for use in an apparatus for intraoperative blood autotransfusion and tested in conjunction with a classical (photoelectric) sensor in the Transfel device from the Scientific Technical Center ELINS are described. The principle of...