TITLE

Fitting Prevents Cross Application of Gases

PUB. DATE
May 2002
SOURCE
Gases & Welding Distributor;May/Jun2002, Vol. 46 Issue 3, p35
SOURCE TYPE
Trade Publication
DOC. TYPE
Article
ABSTRACT
Recommends methods of attachment of fittings on industrial and medical cryogenic liquid cylinders to deter fitting removal from liquid cylinder valves by unauthorized personnel. Brazing of fittings into the liquid, vent and gas use valves of a liquid cylinder; Use of mechanical device.
ACCESSION #
7257948

 

Related Articles

  • Acres of diamonds. Wohlfarth, Ray // Plumbing & Mechanical;Nov2011, Vol. 29 Issue 9, p58 

    In this article the author offers tips for increasing business profits for boiler contractors by enhancing the safety of customer buildings in the U.S. He states that components of gas train like gas pressure switches, gas pressure regulators and some gas valves should be vented to outside....

  • No fast answers on sidewall vents. Mader, Robert P. // Contractor Magazine;Dec94, Vol. 41 Issue 12, p5 

    Reports on US furnace and boiler manufacturers' suspension of approval on sidewall venting with high-temperature plastic pipe. Vent failures in Canada; Results of investigations into plastic vent pipe by 1996; Reuben Autery, president of Gas Appliance Manufacturers Association; Evaluation of...

  • THE WISDOM OF THE WORKERS. Evans, Mary Ann // Trammel Trace Tribune (Tatum, TX);8/5/2010, Vol. 35 Issue 31, p3 

    The article discusses the effort of Mark, a worker, to look for the cat that was seen under the dryer vent.

  • Vents and Louvers.  // National Construction Estimator;2010, Issue 58, p292 

    The article lists the units, materials, and labor costs of louvers and vents which includes chimney caps, code caps, and dormer louver vents.

  • High-temperature plastic vent pipe investigated.  // PM Engineer;Jan95, Vol. 1 Issue 1, p65 

    Reports on investigation of high-temperature plastic vent pipes following reports of problems from Canadian provincial regulatory agencies. Background information; Implications; Expectations.

  • Thousands of homeowners may get plastic vent pipe replaced for free. Mader, Robert P. // Contractor Magazine;Mar98, Vol. 45 Issue 3, p5 

    Presents information on the fact that tens of thousands of homeowners may get their plastic venting systems replaced for free. Reason that this may happen; Information on the retrofit program; Identification of who was involved in the program; Reason for the replacement.

  • Your computer and category I vent design. Smith, William W. // Air Conditioning, Heating & Refrigeration News;1/24/94, Vol. 191 Issue 4, p24 

    Discusses the venting problems encountered by heating, ventilation and air conditioning (hvac) contractors. Design needs of Category I-type gas appliances; Vent size factors; Vent design software.

  • FURNACE VENT SIZING. Murphy, Patrick // Air Conditioning, Heating & Refrigeration News;12/24/2001, Vol. 214 Issue 17, p18 

    Focuses on the materials use for replacing a gas furnace. Operation of a nonpositive vent static pressure; Condensation of vent gas temperature; Avoidance of condensate production of vent pressure.

  • Venting Island Fixtures.  // Reeves Journal: Plumbing, Heating, Cooling;Jun2000, Vol. 80 Issue 6, p50 

    Presents tips on venting island fixtures. Problems of locating vertical vent runs; Mechanics for installing traps for island sinks; Rules for island venting.