TITLE

Matrix of small-radius radio-frequency discharges as a volume-production based source of negative hydrogen ions

AUTHOR(S)
Lishev, St.; Paunska, Ts.; Shivarova, A.; Tarnev, Kh.
PUB. DATE
February 2012
SOURCE
Review of Scientific Instruments;Feb2012, Vol. 83 Issue 2, p02A702
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Based on experience from a work-both theoretical and experimental one-on negative hydrogen ion beam sources studied regarding fusion applications, a novel design of a rf source with volume production of the ions is proposed. The suggestion is for a source constructed as a matrix of small-radius tandem discharges (with magnetic filters largely extended over the discharge length), inductively driven (by a single coil, for the whole matrix) and with a single aperture extraction from each of them.
ACCESSION #
72107657

 

Related Articles

  • Cesium injection into a large rf-driven hydrogen negative-ion source. Takanashi, T.; Takeiri, Y.; Kaneko, O.; Oka, Y.; Tsumori, K.; Kuroda, T. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1024 

    Reports on the development of a large radio-frequency hydrogen negative-ion source for a neutral beam injection system for fusion application. Generation of a strong external magnetic filter in front of the plasma electrode; Reduction of optimum bias voltage; Observation of the lowering of the...

  • Radio frequency beam chopping in a surface-plasma-type negative-ion source. Shinto, K.; Takagi, A.; Kinsho, M.; Ikegami, K.; Igarashi, Z.; Machida, S.; Yoshii, M.; Mori, Y. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1048 

    Proposes a method for radio frequency (rf) beam chopping in a surface-plasma-type negative-ion source. Circuit diagram of the rf modulated power supply; Acceleration of the direct fast-chopped H[sup -] beam; Longitudinal emittance of the direct fast-chopped H[sup -] beam in the booster synchrotron.

  • Measurement of grid heat loading in a negative ion source for producing intense H[sup -] ion beams by aperture displacement focusing technique. Takayanagi, T.; Ikehata, T.; Okumura, Y.; Watanabe, K.; Hanada, M.; Amemiya, T. // Review of Scientific Instruments;Oct2001, Vol. 72 Issue 10, p3829 

    Heat loading of acceleration grids has been investigated using a JAERI 400 keV negative hydrogen ion source, which has a three-stage multiaperture accelerator. To investigate the effect of beamlet steering on the heat loading, the apertures in the grounded grid were displaced up to 5 mm. The...

  • Design of accelerator for negative ion beams by computer simulation. Park, T. S.; Lee, W. S.; Be, S. H. // Journal of Applied Physics;8/15/1985, Vol. 58 Issue 4, p1701 

    Describes the computer simulation concerning the acceleration of negative hydrogen ion beams. Method used to compute spatial distribution and ion trajectory in the multiple stage ionizer; Condition used in the computation.

  • Surface plasma source to generate high-brightness H[sup -] beams for ion projection lithography... Dudnikov, V.G.; Derevyankin, G.E.; Kovalevsky, D.V.; Savkin, V.Ya.; Sokolovsky, E.A.; Guharay, S.K. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p927 

    Reports on the development of a surface plasma source with Penning-type electrodes to generate negative ion beams for ion projection lithography applications. Pulse width; Repetition rate; Maximum negative hydrogen beams at the emission surface.

  • The formation of a negative hydrogen ion beam by surface conversion of a positive ion beam on cesiated tungsten surfaces. van Bommel, P. J. M.; Bonnie, J. H. M.; Granneman, E. H. A.; Massmann, P.; Hopman, H. J. // Journal of Applied Physics;10/1/1985, Vol. 58 Issue 7, p2492 

    Presents a study that measured the generation of negative hydrogen ion beams via the conversion of a positive ion beam on cesiated tungsten surface. Measurement of the negative ion beam current; Analysis of the negative ion currents obtained with a single monolayer of cesium; Examination of the...

  • Intense negative ion beams and their diagnostics. Papadichev, V. A.; Shelkovenko, T. A. // Review of Scientific Instruments;Jan1990, Vol. 61 Issue 1, p395 

    Using negative ions for accelerators and CTR has some peculiarities. High-power beams of fast atoms obtained by charge exchange of negative ions can have advantages over positive ion beams for ICE since they do not experience any deviation, instabilities, and scattering. H[sup -] current up to 7...

  • Radio frequency multicusp ion source development (invited). Leung, K.N. // Review of Scientific Instruments;Mar96, Vol. 67 Issue 3, p1302 

    Reports on the development of a radio frequency multicusp ion source. Schematic diagram; Operating principles; Production of high brightness negative hydrogen ion beams; Beam emittance and longitudinal ion energy spread measurements; Production of positive boron ions for ion implantation...

  • Development of an intense negative hydrogen ion source with an external magnetic filter. Takeiri, Y.; Ando, A.; Kaneko, O.; Oka, Y.; Tsumori, K.; Akiyama, R.; Asano, E.; Kawamoto, T.; Kuroda, T.; Tanaka, M.; Kawakami, H. // Review of Scientific Instruments;Mar95, Vol. 66 Issue 3, p2541 

    Describes the development of an intense negative hydrogen ion source with an external magnetic filter produced by a pair of permanent magnet rows located at 35.4 centimeter separation. Generation of a strong cusp magnetic field for improvement of the plasma confinement; Focus on the structure...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library