ABSTRACT
Using improved beam diagnostic tools, the structure of an ion beam extracted from an electron cyclotron resonance ion source (ECRIS) becomes visible. Especially viewing targets to display the beam profile and pepper pot devices for emittance measurements turned out to be very useful. On the contrary, diagnostic tools integrating over one space coordinate like wire harps for profile measurements or slit-slit devices, respectively slit-grid devices to measure the emittance might be applicable for beam transport investigations in a quadrupole channel, but are not very meaningful for investigations regarding the given ECRIS symmetry. Here we try to reproduce the experimentally found structure on the ion beam by simulation. For the simulation, a certain model has to be used to reproduce the experimental results. The model is also described in this paper.
ACCESSION #
72107477

 

Related Articles

  • Review on heavy ion radiotherapy facilities and related ion sources (invited). Kitagawa, A.; Fujita, T.; Muramatsu, M.; Biri, S.; Drentje, A. G. // Review of Scientific Instruments;Feb2010, Vol. 81 Issue 2, p02B909 

    Heavy ion radiotherapy awakens worldwide interest recently. The clinical results obtained by the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan have clearly demonstrated the advantages of carbon ion radiotherapy. Presently, there are four...

  • Intense beams from gases generated by a permanent magnet ECR ion source at PKU. Ren, H. T.; Peng, S. X.; Lu, P. N.; Yan, S.; Zhou, Q. F.; Zhao, J.; Yuan, Z. X.; Guo, Z. Y.; Chen, J. E. // Review of Scientific Instruments;Feb2012, Vol. 83 Issue 2, p02B905 

    An electron cyclotron resonance (ECR) ion source is designed for the production of high-current ion beams of various gaseous elements. At the Peking University (PKU), the primary study is focused on developing suitable permanent magnet ECR ion sources (PMECRs) for separated function radio...

  • ARTEMIS-B: A room-temperature test electron cyclotron resonance ion source for the National Superconducting Cyclotron Laboratory at Michigan State University. Machicoane, G.; Cole, D.; Ottarson, J.; Stetson, J.; Zavodszky, P. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A322 

    The current scheme for ion-beam injection into the coupled cyclotron accelerator at the NSCL involves the use of two electron cyclotron resonance (ECR) ion sources. The first one is a 6.4 GHz fully superconducting that will be replaced within two years by SUSI, a third generation 18 GHz...

  • Results of the CEA/Saclay H electron cyclotron resonance ion source, ECRIN. Tuske, O.; Delferrière, O.; Gobin, R.; Harrault, F.; Steiner, T. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A507 

    A 2.45 GHz electron cyclotron resonance test stand based on a pure volume H- (negative) ion production is actually under development at CEA Saclay. The negative ion source is working in a pulsed mode, 2 ms at 5–10 Hz. The first H- ions have been observed at the beginning of 2002 with a...

  • Abrupt variation in ion current with biased disk voltage in the electron cyclotron resonance ion source. Taki, G. S.; Sarma, P. R.; Chakraborty, D. K.; Bhandari, R. K.; Ray, P. K.; Drentje, A. G. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A310 

    The performance of the biased disk in the 6.4 GHz electron cyclotron resonance ion source at VECC, Kolkata was studied at a pressure of ∼1×10-7 Torr. We observed an abrupt variation of beam current with bias voltage. For low negative bias voltages (from 0 to -5 V) the beam current...

  • Improvement of the Kei2 source for a new carbon therapy facility. Muramatsu, M.; Kitagawa, A.; Ogawa, Hirotsugu; Iwata, Y.; Yamamoto, K.; Yamada, S.; Ogawa, Hiroyuki; Fujimoto, T.; Yoshida, Y.; Drentje, A. G. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A307 

    A compact electron cyclotron resonance ion source with all permanent magnets has been developed for a new carbon therapy facility at NIRS. Initial tests with the Kei2 source have given a maximum intensity of 530 e μA for C4+ at an extraction voltage of 40 kV and beam stability of better than...

  • Effect of broadband microwave radiation on the performance of a conventional B-minimum geometry electron cyclotron resonance ion source. Kawai, Y.; Alton, G. D.; Tarvainen, O.; Suominen, P.; Koivisto, H. // Review of Scientific Instruments;Mar2006, Vol. 77 Issue 3, p03A331 

    The performances of electron cyclotron resonance ion sources can be enhanced by increasing the physical sizes or numbers of resonant zones embedded within their plasma volumes. Broadband rf power offers a simple, cost effective alternative for increasing the sizes of electron cyclotron resonance...

  • Design of an advanced minimum B for electron cyclotron resonance multicharged ion sources. Ishii, S.; Kato, Y. // Review of Scientific Instruments;May93, Vol. 64 Issue 5, p1131 

    An advanced configuration of minimum-B field is designed for the electron cyclotron resonance (ECR) multicharged ion sources. The aim is to dramatically increase the efficiency of ion beam extraction by correcting the deformed magnetic flux tube containing hot plasma. The correction is performed...

  • Modified distributed electron cyclotron resonance ion source for the production of large diameter ion beams. Wartski, L.; Coste, Ph.; Fusellier, C.; Schwebel, C.; Aubert, J. // Review of Scientific Instruments;Oct2001, Vol. 72 Issue 10, p3816 

    The work presented in this article concerns the conception and the study of a multiantenna electron cyclotron resonance (ECR) ion source at 2.45 GHz dedicated to the surface treatment of large area materials. In this original device, a microwave plasma is created in a 20 cm in diameter...

Share

Read the Article

Courtesy of NEW JERSEY STATE LIBRARY

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics