TITLE

Voltammetric Determination of Vitamin B6 at Glassy Carbon Electrode Modified with Gold Nanoparticles and Multi-Walled Carbon Nanotubes

AUTHOR(S)
Yuzhong Zhang; Yuehong Wang
PUB. DATE
May 2011
SOURCE
American Journal of Analytical Chemistry;May2011, Vol. 2 Issue 2, p194
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
In this work, the gold nanoparticles (Au NPs)/multi-walled carbon nanotubes (MWCNTs) composite film modified glassy carbon electrode (GCE) was fabricated, and scanning electron microscopy (SEM) was used to investigate the assemble process of the composite film. In pH 7.0 PBS, an oxidation peak of the vitamin B6 (VB6) was only observed at composite film modified electrode. Under the optimized conditions, the current intensity was linear with the concentrations of VB6 in the range of 1.59 to 102.74 μg·mL-1 with a detection limit of 0.53 μg·mL-1 (S/N = 3). The modified electrode had been applied in pharmaceutical analysis, and obtained good results.
ACCESSION #
71420902

 