TITLE

Monte Carlo simulation of neutron tomography for palm weevil detection

AUTHOR(S)
Alghamdi, Ali
PUB. DATE
February 2012
SOURCE
Journal of Radioanalytical & Nuclear Chemistry;Feb2012, Vol. 291 Issue 2, p359
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The use of neutron for Non Destructive Imaging (NDI) techniques has many advantages over other (NDI) methods. Using well-established X-ray imaging techniques can provide easy and direct results with some limitations where the sensitivity for light elements is very low. On the other hand, neutron is highly sensitive to water content and can provide extra qualitative information. Comparing the results of the two imaging techniques are investigated in this work with the aim of identifying the palm weevil. At larva stage of the weevil's life it is characterized by highly water content in the trunk of the palm tree which itself composed of spongy watery texture in some types of palm tree. MCNPX 2.5.0 code with neutron radiography tally was used to obtain the 2D projection then reconstructed to 3D tomography image using OSCaR post processing package. The neutron and photon mesh tallies is utilized to study the neutron and photon fluences from monoenergetic thermal neutron beam and neutron spectrum. There are fundamental difficulties in neutron detection which result in misleading information arises from neutron scattering when constructing cone beam CT neutron images, however, neutron radiography provide better methods for the weevil detection from 2D projection.
ACCESSION #
70119790

 

Related Articles

  • Characterization of a new external neutron beam facility at the Ohio State University. Turkoglu, Danyal; Burke, Joshua; Lewandowski, Radoslaw; Cao, Lei // Journal of Radioanalytical & Nuclear Chemistry;Feb2012, Vol. 291 Issue 2, p321 

    A thermal neutron beam facility has been designed and implemented at the Ohio State University Research Reactor. A project is underway to construct a large vacuum chamber such that the facility could have neutron depth profiling and neutron radiography capabilities as intended. The neutron beam...

  • A Novel Method Based on Monte Carlo for Simulation of Variable Resolution X-ray CT Scanner: Measurement of System Presampling MTF. Arabi, H.; Asl, A. R. Kamali // World Academy of Science, Engineering & Technology;Aug2010, Issue 44, p969 

    No abstract available.

  • Design and evaluation of a reflectance diffuse optical tomography system. Kazanci, Hüseyin; Mercan, Tanju; Canpolat, Murat // Optical & Quantum Electronics;Feb2015, Vol. 47 Issue 2, p257 

    We have designed a continuous wave, back-reflection diffuse optical tomography system; and developed a new practical calibration method including both optode efficiency and positional error corrections. System design, data acquisition and calibration protocols are described in detail. Monte...

  • X-ray CT in the detection of palm weevils. Ma, Andy; Alghamdi, Ali; Tofailli, Kassem; Spyrou, Nicholas // Journal of Radioanalytical & Nuclear Chemistry;Feb2012, Vol. 291 Issue 2, p353 

    Early detection of the red palm weevils (RPW) is a major challenge in agriculture among all kinds of palm trees due to the nature of the insect and the difficulty to trace them through their life stages associated with the tree life. Many methods have been applied for the weevil detection such...

  • RADIATION DOSE FROM A LINEAR SLIT SCANNING X-RAY MACHINE WITH FULL-BODY IMAGING CAPABILITIES. lrving, B. J.; Maree, G. J.; Hering, E. R.; Douglas, T. S. // Radiation Protection Dosimetry;2008, Vol. 130 Issue 4, p482 

    Doses for a range of examinations and views using digital X-ray equipment with full-body linear slit scanning capabilities (Statscan) have been compared with those from other published studies. Entrance doses (free-in-air) were measured using a dosimeter, and effective doses were generated using...

  • Effect of the diaphragm of free-air ionisation chamber for X-ray air-kerma measurements. Kurosawa, Tadahiro; Takata, Nobuhisa; Saito, Norio // Radiation Protection Dosimetry;Jul2011, Vol. 146 Issue 1-3, p195 

    Free-air ionisation chambers are widely used at standards laboratories as primary standards for absolute measurements of air kerma in X-ray fields. The area of the diaphragm aperture of a free-air ionisation chambers is an important factor for absolute measurements because it defines the size of...

  • X-ray diffuse scattering from threading dislocations in epitaxial GaN layers. Barchuk, M.; Holý, V.; Miljević, B.; Krause, B.; Baumbach, T.; Hertkorn, J.; Scholz, F. // Journal of Applied Physics;Sep2010, Vol. 108 Issue 4, p043521 

    In this article, we combine diffuse x-ray scattering with a Monte Carlo simulation method for the determination of the dislocation density in thin heteroepitaxial layers. As a model, we consider GaN epitaxial layers containing threading dislocations perpendicular to the surface. The densities of...

  • Monte-Carlo Simulations of the Suzaku-XRS Residual Background Spectrum. Perinati, E.; Kilbourne, C.; Colasanti, L.; Lotti, S.; Macculi, C.; Piro, L.; Mineo, T.; Mitsuda, K.; Bonardi, A.; Santangelo, A. // Journal of Low Temperature Physics;Jun2012, Vol. 167 Issue 5/6, p721 

    Cryogenic micro-calorimeters are suitable to detect small amounts of energy deposited by electromagnetic and nuclear interactions, which makes them attractive in a variety of applications on ground and in space. The only X-ray micro-calorimeter that operated in orbit to date is the X-Ray...

  • Concept design of an illicit material detection system. Al-Bahi, Ali; Soliman, Abdelfattah; Hassan, Mohamed; Mohamed, Nader // Journal of Radioanalytical & Nuclear Chemistry;Jan2014, Vol. 299 Issue 1, p351 

    This paper covers the concept design of an illicit material detection system under the project: 'Aviation security-Design of a Nuclear Instrument for Contraband Detection' established by King Abdulaziz University. The detection system is composed of two units. The first unit is an X-ray machine...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics