TITLE

Measurement of three gamma annihilation by lanthanum-based crystals compared with NaI(Tl) and HPGe

AUTHOR(S)
Alkhorayef, M.; Alzimami, K.; Alfuraih, A.; Alnafea, M.; Spyrou, N.
PUB. DATE
February 2012
SOURCE
Journal of Radioanalytical & Nuclear Chemistry;Feb2012, Vol. 291 Issue 2, p493
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
The relative yield of 3γ to 2γ annihilation was measured for a positron emitter, Na, with the new scintillator detectors lanthanum chloride (LaCl:Ce) and lanthanum bromide (LaBr:Ce), which had been characterised for comparison with high-purity germanium (HPGe) and sodium iodide (NaI(Tl)) detectors. The information obtained from the ortho-positronium 3γ decay in positron emission tomography (PET) can be a measure of the oxygen content in biological tissues by determination of this relative yield. However, it requires high resolution spectroscopy and detection efficiency. Characterisation of the new generation of scintillator detectors determines whether they could replace conventional scintillators and semiconductors. A series of experiments was carried out with different samples in order to study the effect of ortho-positronium formation. The peak-to-peak and the peak-to-valley methods were compared in the measurement of the relative yield of 3γ to 2γ annihilation.
ACCESSION #
70119776

 

Related Articles

  • Detector resolution required for accurate identification in common gamma-ray masking situations. Keyser, Ronald M.; Twomey, Timothy R. // Journal of Radioanalytical & Nuclear Chemistry;Dec2009, Vol. 282 Issue 3, p841 

    Accurate nuclide identification depends on the ability to determine if specific peaks are present in the spectrum. Several current handheld nuclide identifiers and portal monitors use a variant of a peak quality value for this. The peak quality is usually calculated as the peak area divided by...

  • The PARIS calorimeter. Jenkins, David; PARIS Collaboration // AIP Conference Proceedings;Apr2013, Vol. 1525 Issue 1, p622 

    The PARIS calorimeter is an apparatus intended for the future SPIRAL2 facility in Caen, France. It will comprise a spherical shell of scintillators detectors making extensive use of LaBr3(Ce) - a relatively new material with excellent energy resolution (∼3% at 662-keV). The individual...

  • Phoswich scintillator for proton and gamma radiation of high energy. Tengblad, O.; Nilsson, T.; Borge, M. J. G.; Briz, J. A.; Carmona-Gallardo, M.; Cruz, C.; Gugliermina, V.; Nácher, E.; Perea, A.; del Rio, J. Sanchez; Nieves, M. Turrion; Johansson, H. T.; Bergström, J.; Blomberg, E.; Bülling, A.; Gallneby, E.; Hagdahl, J.; Jansson, L.; Jareteg, K.; Masgren, R. // AIP Conference Proceedings;11/26/2011, Vol. 1409 Issue 1, p141 

    We present here a Phoswich scintillator design to achieve both high resolution gamma ray detection, and good efficiency for high energy protons. There are recent developments of new high resolution scintillator materials. Especially the LaBr3(Ce) and LaCl3(Ce) crystals have very good energy...

  • Fast phoswich scintillator endcap for gamma and proton detection. del Río, J. Sánchez; Borge, M. J. G.; Nácher, E.; Perea, A.; Sánchez, J.; Tengblad, O. // AIP Conference Proceedings;Jun2013, Vol. 1541 Issue 1, p193 

    A phoswich configuration consists of LaBr3(Ce) and LaCl3(Ce) crystals optically coupled and stacked together with a common readout. Each crystal has different decay time response and different light yield which make possible the design of a high efficient gamma radiation and proton endcap...

  • Obelix, a new low-background HPGe at Modane Underground Laboratory. Loaiza, P.; Brudanin, V.; Piquemal, F.; Rukhadze, E.; Rukhadze, N.; Stekl, I.; Warot, G.; Zampaolo, M. // AIP Conference Proceedings;2015, Vol. 1672 Issue 1, p130002-1 

    An ultra-low background coaxial HPGe detector for gamma-ray spectrometry with a relative efficiency of 160%, corresponding to a 600 cm3 Ge crystal, was installed at the Laboratoire Souterrain de Modane, France (4800 m.w.e). To reduce the instrinsic detector background, all parts involved in the...

  • Development of Plastic Scintillator Sensor based Ë / β Food Contamination Monitor. Meena, J. P.; Parihar, A.; Vaijapurkar, S. G.; Mohan, Anand // International Journal on Recent Trends in Engineering & Technolo;Nov2010, Vol. 4 Issue 4, p159 

    Detection of food contamination becomes essential during nuclear / radiological emergencies because the presence of gamma (γ) and high energy beta (β) activities above permissible level in food, water, and fodder or even in environment may induce cancer or permanent genetic problems in...

  • Cold spot in the uniform Co-57 image may not necessarily be due to photomultiplier tube failure or variations in photomultiplier tube tuning: A technical note. Pandey, Anil Kumar; Karunanithi, Sellam; Patel, Chetan D.; Sharma, Sanjay Kumar; Bal, Chandrasekhar; Kumar, Rakesh // Indian Journal of Nuclear Medicine;Apr-Jun2015, Vol. 30 Issue 2, p187 

    The article discusses a research report related to occurrence of cold spot in the uniform Cobalt-57 because of variations in photomultiplier tube tuning. It reveals that gamma camera which was used to detect the spot, takes high signals from all photomultiplier tubes defining the X and Y...

  • Lanthanum halide nanoparticle scintillators for nuclear radiation detection. Guss, Paul; Guise, Ronald; Yuan, Ding; Mukhopadhyay, Sanjoy; O'Brien, Robert; Lowe, Daniel; Kang, Zhitao; Menkara, Hisham; Nagarkar, Vivek V. // Journal of Applied Physics;Feb2013, Vol. 113 Issue 6, p064303 

    Nanoparticles with sizes <10 nm were fabricated and characterized for their nanocomposite radiation detector properties. This work investigated the properties of several nanostructured radiation scintillators, in order to determine the viability of using scintillators employing nanostructured...

  • Evaluation of efficiency for in situ gamma spectrometer based upon cerium-doped lanthanum bromide detector dedicated for environmental radiation monitoring. Ciupek, Krzysztof; Jednoróg, Sławomir; Fujak, Marian; Szewczak, Kamil // Journal of Radioanalytical & Nuclear Chemistry;Mar2014, Vol. 299 Issue 3, p1345 

    Nuclear power plants that are planned to be constructed in various countries, including Poland, require to setup an environmental radiation monitoring system. Localization of the installation has to be preceded by the studies determining the level of natural background radiation. Presently the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics