TITLE

Relationship between magnetic shielding and magnetizability

AUTHOR(S)
Janowski, Tomasz; Wolin´ski, Krzysztof
PUB. DATE
August 2002
SOURCE
Journal of Chemical Physics;8/1/2002, Vol. 117 Issue 5, p1994
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A simple relation between magnetic shielding and magnetizability has been found. Its validity has been first shown by numerical calculations and than proven analytically. This fundamental relation shows that the magnetic shielding tensor integrated over a whole space is simply proportional to the magnetizability tensor with a constant factor equal to two-thirds of the vacuum permeability with a negative sign.
ACCESSION #
6985624

 

Related Articles

  • Calculation of nuclear magnetic shieldings. X. Relativistic effects. Fukui, H.; Baba, T.; Inomata, H. // Journal of Chemical Physics;8/22/1996, Vol. 105 Issue 8, p3175 

    The lowest order relativistic effect theory for nuclear magnetic shieldings was derived from a two-component positive energy Hamiltonian. It was shown that the previous relativistic shielding theory based on the two-component Hamiltonian is not gauge invariant and the new terms have to be added...

  • Simulations of Xe NMR chemical shift of atomic xenon dissolved in liquid benzene. Standara, Stanislav; Kulhánek, Petr; Marek, Radek; Horníček, Jan; Bouř, Petr; Straka, Michal // Theoretical Chemistry Accounts: Theory, Computation, & Modeling;Jul2011, Vol. 129 Issue 3-5, p677 

    The isotropic Xe NMR chemical shift of atomic Xe dissolved in liquid benzene was simulated by combining classical molecular dynamics and quantum chemical calculations of Xe nuclear magnetic shielding. Snapshots from the molecular dynamics trajectory of xenon atom in a periodic box of benzene...

  • Electromagnetic shields: Debunked. Schorr, Melissa // Self;Apr98, Vol. 20 Issue 4, p64 

    Focuses on the shielding devices which are worn around the neck to protect the body from electromagnetic fields. Reference to the report issued by the National Cancer Institute and National Research Council (NRC) relating to health risks posed by electromagnetic fields; Comments from Charles F....

  • First-principles calculations of structural, electronic, vibrational, and magnetic properties of C[sub 60] and C[sub 48]N[sub 12]: A comparative study. Xie, Rui-Hua; Bryant, Garnett W.; Jensen, Lasse; Zhao, Jijun; Smith, Vedene H. // Journal of Chemical Physics;5/15/2003, Vol. 118 Issue 19, p8621 

    The structural, electronic, vibrational, and magnetic properties of the C[sub 48]N[sub 12] azafullerene and C[sub 60] are comparatively studied from the first-principles calculations. Full geometrical optimization and Mulliken charge analysis are performed. Electronic structure calculations of...

  • Nuclear magnetic shielding and chirality IV. The odd and even character of the shielding response to a chiral potential. Sears, Devin N.; Jameson, Cynthia J.; Harris, Robert A. // Journal of Chemical Physics;2/15/2004, Vol. 120 Issue 7, p3277 

    We investigate the odd and even character of the shielding response in a chiral molecule (modeled by a Ne[sub 8] helix) when subjected to a chiral potential. We establish that the diastereomeric splittings are a measure of odd powers of V[sub odd]. Implications for diastereomeric, splittings of...

  • Magnetic tunnel junctions on magnetic shield smoothed by gas cluster ion beam. Sun, J. J.; Shimazawa, K.; Kasahara, N.; Sato, K.; Kagami, T.; Saruki, S.; Araki, S.; Matsuzaki, M. // Journal of Applied Physics;6/1/2001, Vol. 89 Issue 11, p6653 

    In this work, a technique, gas cluster ion beam (GCIB), was introduced to smooth the bottom NiFe magnetic shield for magnetic tunnel junction (MTJ) read heads. The GCIB treatment can bring the surface roughness of the shield from 15 to 20 Ã… to around 5 Ã…, and the most of scratch marks...

  • Benchmarking the multipole shielding polarizability/reaction field approach to solvation against QM/MM: Applications to the shielding constants of N-methylacetamide. Kjær, Hanna; Sauer, Stephan P. A.; Kongsted, Jacob // Journal of Chemical Physics;1/28/2011, Vol. 134 Issue 4, p044514 

    We present a benchmark study of a combined multipole shielding polarizability/reaction field (MSP/RF) approach to the calculation of both specific and bulk solvation effects on nuclear magnetic shielding constants of solvated molecules. The MSP/RF scheme is defined by an expansion of the...

  • Small-sized dichroic atomic vapor laser lock. Lee, Changmin; Iwata, G. Z.; Corsini, E.; Higbie, J. M.; Knappe, S.; Ledbetter, M. P.; Budker, D. // Review of Scientific Instruments;Apr2011, Vol. 82 Issue 4, p043107 

    Two, lightweight diode laser frequency stabilization systems designed for experiments in the field are described. A significant reduction in size and weight in both models supports the further miniaturization of measurement devices in the field. Similar to a previous design, magnetic field lines...

  • SELECT THE RIGHT MATERIAL. lash, marybeth // Appliance Design;Sep2014, Vol. 62 Issue 9, p18 

    The article focuses on mumetal, an alloy named after the Greek letter Mu greatly preferred for magnetic shielding applications due to its high nickel content. Topics discussed include electro-magnetic interference (EMI), magnetic permeability, and the B-H curve of the attenuating capabilities of...