The In Vivo Linear and Volumetric Wear of Hip Resurfacing Implants Revised for Pseudotumor

Glyn-Jones, Siôn; Roques, Anne; Taylor, Adrian; Young-Min Kwon; McLardy-Smith, Peter; Gill, Harinderjit S.; Walter, William; Tuke, Mike; Murray, David
December 2011
Journal of Bone & Joint Surgery, American Volume;12/7/2011, Vol. 93-A Issue 23, p2180
Academic Journal
Background: Metal-on-metal arthroplasty-related pseudotumors can cause severe local destruction of bone and soft tissues. The cause of pseudotumors is unknown, although some authors have implicated metal wear debris. The aim of this study was to measure the location and magnitude of wear on resurfacing devices that were retrieved during revision procedures for pseudotumor (the pseudotumor group) and for other reasons (the control group). Methods: We examined thirty-six hip-resurfacing implants, which were divided into two groups: eighteen implants from patients with a diagnosis of pseudotumor and eighteen control implants. Implant orientation and patient demographics were recorded. Three-dimensional, contactless metrology was used to scan the surface of the femoral and acetabular components to a resolution of 20 nm. Linear and volumetric wear were measured, and the components were examined for evidence of edge wear. Results: There was three times more total linear wear and over six times more total volumetric wear of the femoral and acetabular components in the pseudotumor group as compared with that in the control group. The mean linear wear rate and standard deviation of the femoral components in the pseudotumor group (8.4 ± 8.7 µm/yr) were significantly greater than those in the control group (2.9 ± 3.9 µm/yr; p = 0.01). The mean volumetric wear rate of the femoral components was also significantly greater in the pseudotumor group (3.3 ± 5.7 mm³/yr) than it was in the control group (0.8 ± 1.2 mm³/yr; p = 0.009). Seventeen of eighteen subjects in the pseudotumor group had edge wear, compared with six of eighteen in the control group (p < 0.001). Conclusions: Implants that were retrieved because of pseudotumor had a significantly higher wear rate and prevalence of edge wear than the control implants did. There was a strong association between pseudotumor and the high levels of wear debris that are generated during edge-loading. However, not all patients with high wear developed pseudotumors, and not all pseudotumors had high wear; therefore, other factors are most likely involved in the cause of pseudotumors.


Related Articles

  • Investigation of influence of constraints with radius links on locomotive axle load distribution and wheelset steering ability. Spiryagin, Maksym; Yoo, Hong; Lee, Kwan; Spiryagin, Valentyn; Gorbunov, Mykola // Journal of Mechanical Science & Technology;Jul2013, Vol. 27 Issue 7, p1903 

    The problem of improving the tractive and dynamic performance of locomotives by means of using axle boxes with inclined radius links was investigated. The kinematics of axle boxes with different variants (different angles) and designs of inclined radius links, based on the vector contour method...

  • Effect of Operational Condition Changes on the Durability of the Rope for Pusher of Circular Wagon Tipper. Kuľka, Jozef; Mantič, Martin // Applied Mechanics & Materials;2014, Issue 683, p28 

    Article discusses the pusher wagons in transhipment complex. In terms of the reliability of this device appears to be the weakest link in the transhipment of bulk substrates operated rotary tilter because of its design causes increased wear of the rope. The mode of handling the rope through the...

  • Establish the Load Distribution Model for Vertical Mill Grinding Roller in Width Direction. Ping Ye; Shu Ye // Advanced Materials Research;2014, Vol. 936, p1868 

    The width of the grinding rollers are far greater than the arc length of the compaction zone in the circle view direction of the roller, and the actual wear of the mill roll surface also appear in the width direction. Therefore, it is helpful for analyzing the load distribution in the width...

  • Friction and Wear of Jatropha Curcas Oil Using a Four Balls Tester. Figueroa, M.; García, E.; Gallardo Hernández, E. A.; Vite-Torres, M. // Advanced Materials Research;2014, Issue 902, p76 

    Jatropha curcas oil (JCO) is a good option as renewable energy for biodiesel and as lubricant feedstock. In México, the JCO is widely distributed in more than 15 states. This work describes the characterisation of Jatropha curcas oil as additive in engine oil (EO) blended mixtures. The EO and...

  • A study on the possibility of the Brugger test application for differentiation between the API GL performance levels of gear oils. Trzos, M.; Szczerek, M.; Tuszynski, W. // Archives of Civil & Mechanical Engineering (Elsevier Science);Mar2013, Vol. 13 Issue 1, p14 

    The paper presents the results of research aimed at differentiation between the API GL performance levels of automotive gear oils. Tribological tests were conducted with the use of two different tribotesters. A four-ball apparatus and a crossed-cylinder wear tester were employed. Several dozen...

  • Is Loading a Significantly Influential Factor in the Development of Lithic Microwear? An Experimental Test Using LSCM on Basalt from Olduvai Gorge. Key, Alastair; Stemp, W.; Morozov, Mikhail; Proffitt, Tomos; Torre, Ignacio // Journal of Archaeological Method & Theory;Dec2015, Vol. 22 Issue 4, p1193 

    Lithic microwear develops as a result of abrasive friction between a stone tool's working edge and the surface of a worked material. Variation in the loading (i.e. force) applied to a stone tool during its use alters the amount of friction created between these two materials and should...

  • Study on Friction and Wear Properties of Cu-Zn-Sn-Pb-Ni Alloy. Jianhua Liu; Yu Feng; Yaxue Kang; Ana Lu; Guirong Peng; Ruijun Zhang // Journal of Materials Science & Engineering A;2011, Vol. 1 Issue A, p71 

    In order to improve wear resistance of copper alloy, a Cu-Zn-Sn-Pb-Ni alloy was prepared. The friction and wear properties of Cu-Zn-Sn-Pb-Ni alloy sliding against GCr15 steel were investigated by friction tester, and the morphologies of worn surface of the specimen were observed by scanning...

  • A study of microstructure and wear behaviour of TiB2/Al metal matrix composites. Sreenivasana, A.; Vizhianb, S. Paul; Shivakumarc, N. D.; Munirajua, M.; Raguramand, M. // Latin American Journal of Solids & Structures;Mar2011, Vol. 8 Issue 1, p1 

    The present paper deals with the study of microstructure and wear characteristics of TiB2 reinforced aluminium metal matrix composites (MMCs). Matrix alloys with 5, 10 and 15% of TiB2 were made using stir casting technique. Effect of sliding velocity on the wear behaviour and tribo-chemistry of...

  • Influence of Applied Load on Wear Characterizations of Rail Material. Windarta, M. Bin Sudin; Fuad, Khairul // Journal of Applied Sciences;2011, Vol. 11 Issue 9, p1636 

    No abstract available.


Read the Article


Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics