ABSTRACT
Streak camera is widely used in continuous time diagnostics in fast physical process. To produce accurate result, it requires delicate calibration and a reliable analysis method. High quality sweep-rate data with uncertainty smaller than 0.5% are obtained over the full record area by a constrained fitting method of peak position measurement, with a short pulse laser and an etalon as the fiducial source. The temporal response is linearized by this full-screen sweep-rate data, which eliminates errors in measurement due to nonlinearity and space-distortion inherent in streak camera.
ACCESSION #
67538051

 

Related Articles

  • Compact optical technique for streak camera calibration. Bell, Perry; Griffith, Roger; Hagans, Karla; Lerche, Richard; Allen, Curt; Davies, Terence; Janson, Frans; Justin, Ronald; Marshall, Bruce; Sweningsen, Oliver // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3930 

    To produce accurate data from optical streak cameras requires accurate temporal calibration sources. We have reproduced an older technology for generating optical timing marks that had been lost due to component availability. Many improvements have been made which allow the modern units to...

  • A technique for in situ calibration of an x-ray streak camera in the nanosecond regime using a high density Z-pinch. Jones, L. A.; Kallne, E.; Kania, D. R.; Maestas, M.; McGurn, J. S.; Shepherd, R. // Journal of Applied Physics;9/1/1985, Vol. 58 Issue 5, p1711 

    Presents a study that developed a technique for calibrating an x-ray streak camera in situ. Factors needed for the effective use of x-ray streak cameras; Advantages of the pinched plasma column over a pinhole; Discussion on how spatial and temporal calibration was accomplished.

  • In situ calibration of a streak camera in nanosecond region with a sequenced multispark switch. Tou, T. Y. // Review of Scientific Instruments;Jan1993, Vol. 64 Issue 1, p125 

    This article presents an in situ calibration of a streak camera from 500 ps/mm to 20 ns/mm of streak speeds with an adjustable time-sequenced multispark switch. This switch is comprised of a trigatron which drives two other secondary sparks separated in time from several nanoseconds to almost 1...

  • Calibration Procedures for X-ray Streak Cameras and Elements of X-ray Measuring Circuits. Lazarchuk, V. P.; Muntyan, A. N.; Murugov, V. M.; Petrov, S. I.; Senik, A. V. // Instruments & Experimental Techniques;Mar/Apr2004, Vol. 47 Issue 2, p255 

    Setups developed for the calibration of X-ray streak cameras and of elements of X-ray measuring circuits are described. Calibration procedures are described and calibration results related to the absolute spectral sensitivity, spatial resolution, distortion, sensitivity nonuniformity over the...

  • Errors of measuring picosecond light pulses by picosecond streak cameras. Ageeva, N.; Bronevoi, I.; Zabegaev, D.; Krivonosov, A.; Vorob'ev, N.; Gornostaev, P.; Lozovoi, V.; Schelev, M. // Instruments & Experimental Techniques;Jul2011, Vol. 54 Issue 4, p548 

    Errors of measuring time dependences of the light intensities of picosecond laser pulses by two electron-optical systems are studied. The first system is the picosecond streak camera made in Russia, and the second system, designed in Germany, consists of a picosecond streak camera coupled with a...

  • Jitter-free subpicosecond streak cameras (invited). Belzile, C.; Kieffer, J. C.; Cote, C. Y.; Oksenhendler, T.; Kaplan, D. // Review of Scientific Instruments;Mar2002, Vol. 73 Issue 3, p1617 

    We review here our recent work on a high dynamic range, subpicosecond x-ray streak camera. Our subpicosecond streak camera (PX1) has been coupled to a 10 Hz Ti: sapphire laser system and tested with 500 fs UV light pulses (266 nm) in jitter-free accumulation mode. A novel design for the...

  • Very high long-term stability synchroscan streak camera. Uhring, Wilfried; Zint, Chantal Virginie; Summ, Patrick; Cunin, Bernard // Review of Scientific Instruments;May2003, Vol. 74 Issue 5, p2646 

    In this article, we present the drifts phenomena that affect the temporal resolution of a standard synchroscan streak camera and some techniques to correct them in order to enhance the long-term resolution of these cameras. First, we give a comprehensive list of the components of the synchroscan...

  • Streak Camera Characterization Using a Femtosecond Ti:Sapphire Laser. Ferianis, Mario; Danailov, Miltcho // AIP Conference Proceedings;2002, Vol. 648 Issue 1, p203 

    At ELETTRA a Streak Camera system is in operation since 1999. Several measurements have been performed so far on the diagnostic bending magnet beam line of the Storage Ring. This instrument has been also widely used during the Storage Ring FEL commissioning to fully characterize both the...

  • Chromatic time lag in picosecond-streak-camera objectives. Ihlemann, J.; Helmbold, A.; Staerk, H. // Review of Scientific Instruments;Nov88, Vol. 59 Issue 11, p2502 