ABSTRACT
Multi ion beam and hard x-ray emissions were detected in a high inductance (more than 100 nH) Mather type plasma focus (PF) device at different filling gas pressures and charging voltages. The signal analysis was performed through the current trace, as it is the fundamental signal from which all of the phenomena in a PF device can be extracted. Two different fitting processes were carried out according to Lee's computational (snow-plow) model. In the first process, only plasma dynamics and classical (Spitzer) resistances were considered as energy consumer parameters for plasma. This led to an unsuccessful fitting and did not answer the energy transfer mechanism into plasma. A second fitting process was considered through the addition of anomalous resistance, which provided the best fit. Anomalous resistance was the source of long decrease in current trace, and multi dips and multi peaks of high voltage probe. Multi-peak features were interpreted considering the second fitting process along with the mechanisms for ion beam production and hard x-ray emission. To show the important role of the anomalous resistance, the duration of the current drop was discussed.
ACCESSION #
66903279

 

Related Articles

  • Plasma and Beams Dynamics in PF-1000 Device under the Full-Scale Energy Storage. Gribkov, V. A.; Banaszak, A.; Bienkowska, B.; Dubrovsky, A. V.; Ivanova-Stanik, I.; Jakubowski, L.; Karpinski, L.; Miklaszewski, R.; Paduch, M.; Sadowski, M.; Scholz, M.; Szydlowski, A.; Tomaszewski, K. // AIP Conference Proceedings;2006, Vol. 875 Issue 1, p5 

    Plasma dynamics and radiation characteristics of the PF-1000 facility at its upper energy limit (≈ 1 MJ) were investigated by help of a number of diagnostics with ns temporal resolution. Special attention was paid to the temporal and spatial cross correlation between plasma, electron and...

  • Physical processes of the interaction of ion and plasma streams with a target surface in a dense plasma focus device. Gribkov, V.; Demin, A.; Demina, E.; Dubrovsky, A.; Karpinski, L.; Maslyaev, S.; Pimenov, V.; Padukh, M.; Sholz, M. // Plasma Physics Reports;Dec2012, Vol. 38 Issue 13, p1082 

    Dynamics of the interaction of powerful streams of high-temperature plasma and fast ions generated in a device of the 'Dense Plasma Focus' (DPF) type has been studied for a special case. In these experiments solid conductive targets with the shape of a plate and a tube, respectively, were placed...

  • Ion Beam And Plasma Jet Generated By A 3 kJ Plasma Focus. Lim, L. K.; Ngoi, S. K.; Yap, S. L.; Wong, C. S.; Saadah, A. R. // AIP Conference Proceedings;7/7/2009, Vol. 1150 Issue 1, p444 

    The plasma focus device is well known as a copious source of X-ray, neutrons, ion and electron beams. In this work, the characteristics of energetic ion beam emission in a 3 kJ Mather-type plasma focus is studied. The plasma focus system is operated at low pressure with argon as the working gas....

  • Experimental study of implosion plasma physical characteristics in a small puff-gas z-pinch. Zou, X. B.; Wang, X. X.; Han, M.; Luo, C. M.; Zhang, G. X.; Liu, Z. // AIP Conference Proceedings;2006, Vol. 808 Issue 1, p181 

    This paper presents the physical characteristics of the z-pinch implosion plasma. Experiments were carried out on a small gas-puff z-pinch plasma device. A three-frame Mach-Zehnder interferometer was developed to measure implosion plasma. Some important physical parameters of plasma implosion...

  • Order of magnitude enhancement in neutron emission with deuterium-krypton admixture operation in miniature plasma focus device. Verma, Rishi; Lee, P.; Lee, S.; Springham, S. V.; Tan, T. L.; Rawat, R. S.; Krishnan, M. // Applied Physics Letters;9/8/2008, Vol. 93 Issue 10, p101501 

    The effect of varied concentrations of deuterium-krypton (D2–Kr) admixture on the neutron emission of a fast miniature plasma focus device was investigated. It was found that a judicious concentration of Kr in D2 can significantly enhance the neutron yield. The maximum average neutron...

  • Time Integrated and Time Resolved Neutron Measurements in a Plasma Focus Device. Milanese, M.; Moroso, R.; Castillo, F.; Herrera, J. J. E.; Golzarri, J. I.; Espinosa, G. // AIP Conference Proceedings;2006, Vol. 875 Issue 1, p423 

    This work reports some experimental results on neutron emission from the pinch phase of the plasma focus device PACO (2 kJ, 31 kV). An evaluation of the building structure influence on neutron yield measurements was made. Special devices supporting CR-39 detectors were designed, constructed and...

  • The Dense Plasma Focus Opportunities in Detection of Hidden Objects by Using Nanosecond Impulse Neutron Inspection System (NINIS). Gribkov, V.; Dubrovsky, A.; Karpiński, L.; Miklaszewski, R.; Paduch, M.; Scholz, M.; Strzyżewski, P.; Tomaszewski, K. // AIP Conference Proceedings;2006, Vol. 875 Issue 1, p415 

    Dense Plasma Focus device is proposed for use as a neutron source to generate very powerful pulses of neutrons in the nanosecond (ns) range of its duration. Our devices PF-6, recently put into operation at the Institute of Plasma Physics and Laser Microfusion, Warsaw, Poland, and PF-10 belonging...

  • Time of Neutron Production on Z-Pinch and Plasma Focus Devices. Kubes, P.; Kravarik, J.; Klir, D.; Scholz, M.; Paduch, M.; Tomaszewski, K.; Ivanova-Stanik, I.; Bienkowska, B.; Karpinski, L.; Sadowski, M.; Schmidt, H.; Bakshaev, Y. L.; Blinov, P. I.; Chernenko, A. S.; Ivanov, M. I.; Kazakov, E. D.; Korelsky, A. V.; Kravchenko, E. V.; Korolev, V. D.; Shashkov, A. Y. // AIP Conference Proceedings;2006, Vol. 875 Issue 1, p15 

    In this paper we present the results obtained on the plasma focus PF-1000 in IPPLM Warsaw and on the z-pinch S-300 in RRC Kurchatov Institute in Moscow using a deuterium load. On the PF-1000 plasma-focus device with deuterium filling gas the energy of neutrons and time of their generation are...

  • Preliminary Results Of A 600 Joules Small Plasma Focus Device. Lee, S. H.; Yap, S. L.; Wong, C. S. // AIP Conference Proceedings;7/7/2009, Vol. 1150 Issue 1, p448 

    Preliminary results of a 600 J (3.7 μF, 18 kV) Mather type plasma focus device operated at low pressure will be presented. The discharge is formed between a solid anode with length of 6 cm and six symmetrically and coaxially arranged cathode rods of same lengths. The cathode base is profiled...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics