ABSTRACT
A new and efficient analytic methodology based on cloud point extraction (CPE) was developed for determination of pesticide residues of metsulfuron-methyl (MSM), chlorsulfuron (CS), and bensulfuron-methyl (BSM) in water, soil, and rice grain by high-performance liquid chromatography (HPLC). Multiple experimental conditions that affected CPE efficiency-including surfactant type and concentration, equilibration temperature and duration, ionic strength, and solution pH were identified. CPE conditions were optimized as follows: 1.5% Triton X-114 (w/v), 12% NaSO (w/v) solution (pH 2.0), and heat-assisted at 50°C for 15 min. The calibration curves for all analytes were linear, ranging from 0.05 to 4.0 mg L, with the correlation coefficients >0.9995 by HPLC-ultraviolet detector and were linear, ranging from 0.004 to 2.0 mg L, with correlation coefficients >0.9983 by CPE-HPLC. The average recoveries at the three spiked levels using CPE ranged from 86.0% to 94.5% for water samples with relative SDs (RSDs) of 0.4% to approximately 7.8%; from 85.6% to 94.8% for soil samples with RSDs of 1.2% to approximately 9.5%; and from 81.9% to 91.3% for rice samples with RSDs of 1.7% to approximately 5.8%. The proposed CPE-HPLC method can be successfully used to analyze MSM, CS, and BSM residues from contaminated water, soil, and rice grain samples.
ACCESSION #
66303636

 

Related Articles

  • Simple and Sensitive Method for Determination of Imidacloprid Residue in Soil and Water by HPLC. Samnani, Prakash; Vishwakarma, Kamlesh; Pandey, S. // Bulletin of Environmental Contamination & Toxicology;May2011, Vol. 86 Issue 5, p554 

    rapid, sensitive and reliable HPLC method was developed and validated for the determination of imidacloprid residue in water at different pH and in soil. Quantification was performed by reversed phase HPLC system equipped with UV detector. The limit of quantification (LOQ) was found to be 0.02...

  • MONITORING OF PESTICIDE RESIDUES IN VEGETABLES COLLECTED FROM MARKETS OF SINDH, PAKISTAN. S. A. SHEIKH; S. M. NIZAMANI; A. A. PANHWAR; B. N. MIRANI // Food Science & Technology Letters;2013, Vol. 4 Issue 1, p41 

    Pesticide residues were determined in marketed samples of different vegetables. Samples were collected from different markets of southern Sindh during 2012-13. Residues were extracted with QuEChERS method and were analyzed with Gas Chromatography (GC) coupled with Mass Spectrometry Detector....

  • Residue Dynamics of Clopyralid and Picloram in Rape Plant Rapeseed and Field Soil. Zhao, Pengyue; Wang, Lei; Chen, Li; Pan, Canping // Bulletin of Environmental Contamination & Toxicology;Jan2011, Vol. 86 Issue 1, p78 

    new method for simultaneous analysis of clopyralid and picloram residues in rape plant, rapeseed and field soil was developed and validated. The residual dynamics and final residues of clopyralid and picloram in rape plant, rapeseed and soil were determined by High Performance Liquid...

  • Determination and Method Validation of Metamitron in Soil by RP-HPLC. Kumar, Satyendra; Tandon, Shishir; Sand, N. // Bulletin of Environmental Contamination & Toxicology;Feb2014, Vol. 92 Issue 2, p165 

    A simple, rapid and economical method was developed and validated for the determination of metamitron using UV detector with RP-HPLC. Study of metamitron in soil was carried out. The compound was extracted from soil by methanol and clean-up was done on C-18 SPE column. Recovery ranged from 90.75...

  • Method for Analyzing Lot-to-Lot Variability of Polysorbate Mixtures. Asa, Darwin // LC-GC North America;Jun2007 Application Notebook Suppl, Vol. 25, p57 

    The article focuses on the method for analyzing lot-to-lot variability of polysorbate mixtures by using Charged Aerosol Detection (CAD), a high performance liquid chromatography (HPLC) detector. The polysorbates are used in pharmaceutical development and manufacturing operations to determine...

  • Persistence of Metsulfuron-Methyl in Paddy Field and Detection of Its Residues in Crop Produce. Sondhia, Shobha // Bulletin of Environmental Contamination & Toxicology;Dec2009, Vol. 83 Issue 6, p799 

    Among sulfonylurea herbicides, metsulfuron-methyl [methyl 2-(4-methoxy-6-methyl-1,3,5-triazine-2-ylcarbamoylsulfamoyl) benzoic acid] is widely used due to its selectivity against a wide range of weeds in cereal, pasture, and plantation crops. Use of persistent herbicides has increased risk of...

  • Validated HPLC Method for the Determination of Paclitaxel-related Substances in an Intravenous Emulsion Loaded with a Paclitaxel--Cholesterol Complex. X. J. XIA; J. PENG; P. X. ZHANG; D. J. JIN; Y. L. LIU // Indian Journal of Pharmaceutical Sciences;Nov/Dec2013, Vol. 75 Issue 6, p672 

    A high-performance liquid chromatography method was developed for the determination of related substances in an intravenous emulsion loaded with a paclitaxel-cholesterol complex. The separation was achieved using Agilent Eclipse XDB-C18 column (150 x 4.6 mm, 3.5 µm), which was kept at 40°....

  • A PASSIVE TUBE-TYPE SAMPLER FOR THE DETERMINATION OF FORMALDEHYDE VAPOURS IN MUSEUM ENCLOSURES. Gibson, L. T.; Brokerhof, A. W. // Studies in Conservation;2001, Vol. 46 Issue 4, p289 

    A tube-type passive sampling method has been developed and assessed for the quantification of formaldehyde (methanal) vapours in indoor air. The sampler was designed for use in museums where test sites often include small enclosures with low air movement. The procedure involves collection of...

  • Determination of Cetrizine Dihydrochloride and a Related Impurity in Oral Solution and Tablet Dosage Forms Using HPLC. Singh, Yogendra; Pande, Subhash; Singh, Bhupendra; Ram, Veerma; Bhandari, Anil // Asian Journal of Research in Chemistry;Jan2012, Vol. 5 Issue 1, p87 

    The article discusses a study conducted to develop a simple High Performance Liquid Chromatography (HPLC) method for simultaneous determination of Cetirizine dihydrochloride (CZ) and its related impurities. It is noted that the process is done in the presence of formulation excipients either in...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics