TITLE

Non-contact tonometry in the postoperative eye

AUTHOR(S)
Vernon, S A
PUB. DATE
April 1989
SOURCE
British Journal of Ophthalmology;Apr1989, Vol. 73 Issue 4, p247
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
No abstract available.
ACCESSION #
66047227

 

Related Articles

  • Intracameral air following pneumatic noncontact tonometry in a recently post-perforating keratoplasty patient. Vámosi, Péter // Clinical Ophthalmology;2014, Vol. 8, p763 

    Purpose: The purpose of this report is to highlight the potential risk of noncontact tonometry after routine uncomplicated penetrating keratoplasty (PK). Case report: After uncomplicated PK for keratoconus, routine noncontact tonometry was performed on the second postoperative day. In spite of...

  • Factors affecting tonometry measurement. Hamilton-Maxwell, Kirsten // Optometry Today;4/11/2014, Vol. 54 Issue 7, p50 

    The article discusses the use of the tonometer for measuring intraocular pressure (IOP) and the factors that affect tonometry results. It differentiates between contact and non-contact tonometry (NCT) and the variables to consider for measuring such as the patient's eye, the type of instrument,...

  • Tonometry measurements may underestimate IOP after PRK. Charters, Lynda; Rosa, Nicola // Ophthalmology Times;11/15/97, Vol. 22 Issue 22, p42 

    Presents a study on the reliability of intraocular pressure measurements following PRK to correct myopia using Goldmann applanation tonometry. Absence of difference between preoperative and postoperative IOP measurements in the untreated eyes; Suggested formula for correcting tonometric readings.

  • A new look at corneal biomechanics. CHANG, ROBERT T. // Ophthalmology Times;9/15/2013, Vol. 38 Issue 18, p16 

    The article discusses research on corneal biomechanics that suggests highest concavity time as a risk factor for glaucoma based on data obtained from non-contact tonometry. It details a prospective, comparative cohort study on 102 patients with glaucoma with 66 normal controls in Hong Kong led...

  • Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery. Shousha, Shireen M. A.; Abo Steit, Mahmoud A. H.; Hosny, Mohamed H. M.; Ewais, Wael A.; Shalaby, Ahmad M. M. // Clinical Ophthalmology;2013, Vol. 7, p71 

    Background: The purpose of this study was to determine the accuracy of intraocular pressure (IOP) measurement after laser in situ keratomileusis (LASIK) or epithelial laser in situ keratomileusis (Epi)-LASIK using Goldmann applanation tonometry, air puff tonometry, ocular response analyzer...

  • Ocular Surface Displacement with and without Contact Lenses during Non-Contact Tonometry. Rimayanti, Ulfah; Kiuchi, Yoshiaki; Uemura, Shohei; Takenaka, Joji; Mochizuki, Hideki; Kaneko, Makoto // PLoS ONE;Apr2014, Vol. 9 Issue 4, p1 

    Purpose: To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP) reading changes caused by wearing soft...

  • Comparison of intraocular pressure measurement with Scheimpflug-based noncontact tonometer with and without hydrogel contact lenses. Kumar, Mukesh; Shetty, Rohit; Jayadev, Chaitra; Dutta, Debarun; Nicolsan, Maneck D.; Nagaraj, Sriharsha; Kumar, Rajesh S. // Indian Journal of Ophthalmology;Apr2015, Vol. 63 Issue 4, p323 

    Objectives: The objective was to determine the repeatability of intraocular pressure (IOP) measurements made through a soft contact lens (CL) using the Scheimpflug noncontact tonometry in healthy subjects. Methods: This prospective, randomized, single-center study included one eye of 88 subjects...

  • Coupled Biomechanical Response of the Cornea Assessed by Non-Contact Tonometry. A Simulation Study. Ariza-Gracia, Miguel Á.; Zurita, Jesús F.; Piñero, David P.; Rodriguez-Matas, José F.; Calvo, Begoña // PLoS ONE;Mar2015, Vol. 10 Issue 3, p1 

    The mechanical response of the cornea subjected to a non-contact air-jet tonometry diagnostic test represents an interplay between its geometry, the corneal material behavior and the loading. The objective is to study this interplay to better understand and interpret the results obtained with a...

  • What's new in…instruments and equipment.  // Optometry Today;11/20/2009, Vol. 49 Issue 22, p23 

    The article evaluates several products including the TMS-5 Scheimpflug Topographer from Tomey, the NT-530P system which combines non-contact tonometry with pachymetry from Nidek, and the Applanation Tonometer from Keeler.

  • Comparisons of intraocular pressure measurements: Goldmann applanation tonometry, noncontact tonometry, Tono-Pen tonometry, and dynamic contour tonometry. Hsu, S.-Y.; Sheu, M.-M.; Hsu, A.-H.; Wu, K.-Y.; Yeh, J.-I.; Tien, J.-N.; Tsai, R.-K. // Eye;Jul2009, Vol. 23 Issue 7, p1582 

    AimsTo compare intraocular pressure (IOP) readings between Tono-Pen tonometry and GAT, between noncontact tonometry (NCT) and GAT, and between dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT). The correlation between IOP reading and possible confounder was...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics