TITLE

Anatomy of Load Delta-T

AUTHOR(S)
NELSON, KIRBY
PUB. DATE
August 2011
SOURCE
Heating/Piping/Air Conditioning Engineering;Aug2011, Vol. 83 Issue 8, p34
SOURCE TYPE
Periodical
DOC. TYPE
Article
ABSTRACT
The article discusses aspects of load delta-T, which is a vital component in large distributed chilled water system. The author talks about the pervasiveness of low-load delta-T in central chiller plants and it can introduce a means of forcing load delta-T to 10 degree Fahrenheit (F). It also presents several graphs depicting the effects of the characteristic of loads to pump and plant performance.
ACCESSION #
65467142

 

Related Articles

  • Mobile equipment--quieter and smarter. Schneider, R.T. // Hydraulics & Pneumatics (1996);Aug2002, Vol. 55 Issue 8, p29 

    Discusses the hydraulic systems for wheel loader. Operating system for digging; Hydrostatic fan drive; Hydrostatic steering; Mechanical transmission; Cooling system.

  • Refrigeration users miss out on £80M of efficiency savings. Pendrous, Rick // Food Manufacture;Mar2007, Vol. 82 Issue 3, p21 

    The article reports the findings of a study conducted by Food and Drink Federation regarding the refrigeration system in Great Britain. The result points that food manufacturers in the country are losing more than £80 million a year in potential cost savings by not operating their...

  • A Review of Bubble Pump Technologies. Benhmidene, A.; Chaouachi, B.; Gabsi, S. // Journal of Applied Sciences;2010, Vol. 10 Issue 16, p1806 

    This study provides a literature review on bubble pump using in diffusion-absorption refrigeration technology. A numbers of bubble pump configurations are provided and discussed. Many parameters influencing the performance of the bubble pump are presented. It is hoped that, this study should be...

  • Ammonia Pump-Out Systems, Part 3. Jordan, Peter // Process Cooling & Equipment;Jan2007, p16 

    The author demonstrates how the features and advantages of a pump-out system can be used thru a case history at a representative frozen food plant located in the U.S. He states that in the plant, a complete pump-out system was installed as part of the initial installation of the ammonia...

  • SKID LOADERS: MORE POWER.  // ENR: Engineering News-Record;3/20/2006, Vol. 256 Issue 11, p51 

    The article reports that the new E-Series skid loaders designed to boost job site productivity with an optimized combination of performance, power, speed and operator comfort are described in this brochure. It contains information and colorful application photos on the expanded lineup of six...

  • Comparing Residential Furnace Blowers for Rating and Installed Performance. Walker, Iain S. // ASHRAE Transactions;2008, Vol. 114 Issue 1, p187 

    The objective of this study was to assess the performance of residential furnace blowers for both heating, cooling and air distribution applications and to compare their performance at DOE/ARI rating conditions (for AFUE and SEER) and at real installed conditions. A testing program was...

  • 35 K Turbo-Brayton Cryocooler Technology. Zagarola, M. V.; Dietz, A. J.; Swift, W. L.; Davis, T. M. // AIP Conference Proceedings;2004, Vol. 710 Issue 1, p1635 

    Future Department of Defense missions will require efficient, low mass, reliable mechanical cryocoolers. Loads of 2 W to 8 W at 35 K are anticipated, combined with higher loads at higher temperatures for optical benches and shielding. A single, multistage cryocooler that can supply refrigeration...

  • Study of Power Generation System Based on Black Smokers. Zede Liang; Shujie Wang // Applied Mechanics & Materials;2014, Issue 535, p185 

    The OTEC system of the paper studying is different with the traditional OTEC system, which takes the marine geothermal energy (black smokers) as the heat source, takes cold seawater of deep sea as the cold source. The paper analyzes and calculates some parameters of open-circle system which uses...

  • Optimizing Chillers & Towers. Crowther, Hugh; Furlong, James // ASHRAE Journal;Jul2004, Vol. 46 Issue 7, p34 

    Emphasizes controls logic and design conditions and how they can be used for optimizing chiller, cooling tower, and condenser pump system performance throughout the year. Software model of an hour-after-hour energy use for a typical office building in three cities; Manipulation of the size of...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library