TITLE

Expression of picogram sensitive bending modes in piezoelectric cantilever sensors with nonuniform electric fields generated by asymmetric electrodes

AUTHOR(S)
Johnson, Blake N.; Mutharasan, Raj
PUB. DATE
December 2010
SOURCE
Review of Scientific Instruments;Dec2010, Vol. 81 Issue 12, p125108
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Single-layer uniform cross-sectioned piezoelectric macro-cantilevers fabricated with an asymmetric electrode configuration enabled electrical measurement of picogram-sensitive resonant bending modes in liquids. Bending modes were otherwise not electrically measurable without excitation by a nonuniform electric field created by the geometric asymmetry in electrode design used. Electrode modification was confirmed by energy-dispersive X-ray spectroscopy (EDS). Mass-change sensitivity was tested using both bulk density changes and surface chemisorption experiments in a continuous flow apparatus. Significant response to density changes as small as 0.004 g/mL was measured. A sensitivity limit of ∼1 picogram in liquid was determined from 1-dodecanethiol chemisorption experiments. The sensitivity decreased with chemisorbed mass and was log-linear over five orders of magnitude. The observed resonance responses were in agreement with previously reported models of resonating cantilever sensors. This work demonstrates experimentally for the first time that introducing electrode asymmetry enables measurement of bending modes in cantilevers containing only a single piezoelectric layer.
ACCESSION #
65091161

 

Related Articles

  • A nondisturbing electric-field sensor using piezoelectric and converse piezoelectric resonances. Lee, Yongkwan; Kim, Ilryong; Lee, Soochil // Review of Scientific Instruments;Dec1997, Vol. 68 Issue 12, p4427 

    Presents an electric-field sensor using both piezoelectric and converse piezoelectric resonances. Minimization of field disturbance; Distinguishing feature of the probe; Demonstration of the field sensing capability of the probe; Dominance of the capacitive field in an empty solenoid.

  • A miniature x-ray fluorescence setup. Ribbing, Carolina; Andersson, Marit; Hjort, Klas; Lundqvist, Hans // Review of Scientific Instruments;Jul2003, Vol. 74 Issue 7, p3423 

    A miniature low-power x-ray fluorescence (XRF) setup has been designed, realized, and tested in vacuum. The experimental setup is centimeter sized and consists of an x-ray source and an electrically cooled silicon detector. The x-ray source has diamond membrane electrodes; the cathode is a field...

  • Direct observation of localized conduction pathways in photocross-linkable polymer memory. Kwan, Wei Lek; Lei, Bao; Shao, Yue; Prikhodko, Sergey V.; Bodzin, Noah; Yang, Yang // Journal of Applied Physics;Jun2009, Vol. 105 Issue 12, p124516 

    Resistive switching in photocross-linkable polymer memory devices was found to occur in localized areas of the device. In order to elucidate the reason behind the switching, we used focused ion-beam to prepare a cross-section of the device. It was found that after the device was switched to the...

  • Soldered contact and current risetime effects on negative polarity wire array Z pinches. Chalenski, D. A.; Kusse, B. R.; Greenly, J. B. // Physics of Plasmas;Aug2009, Vol. 16 Issue 8, p082707 

    The experimental results described in this paper were motivated by earlier, low current, single wire experiments. In these experiments, single 10–25 μm diameter wires were driven by 1–5 kA current pulses with variable dI/dt from 5 to 60 A/ns. The amount of energy deposited in...

  • A new readout scheme for imaging TES based on cooling time measurement. Noguchi, Y.; Takahashi, H.; Fukuda, D.; Ohno, M.; Nakazawa, M.; Ataka, M.; Ukibe, M.; Hirayama, F.; Ohkubo, M. // AIP Conference Proceedings;2002, Vol. 605 Issue 1, p325 

    We are developing a tungsten transition edge sensor (W-TES) for x-ray imaging spectroscopy applications. The conventional readout scheme for TES array has a great difficulty in reading out multi-channel x-ray signals. Therefore we have considered a new readout scheme for a W-TES array. This...

  • High-count-rate operation of a TFTR position-sensitive x-ray detector with delay-line readouts. Hsuan, H.; Bitter, M.; von Goeler, S.; Harder, J. A.; Hill, K. W.; Lemunyan, G. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p2771 

    X-ray spectra obtained with position-sensitive detectors which use delay-line readout systems are subject to distortions at comet rares comparable to the inverse of the temporal length of the delay line. These distortions are due to the simultaneous existence of pulses from different photons on...

  • Using a piezoelectric flow immunosensor for determining sulfamethoxazole in environmental samples. Melikhova, E. V.; Kalmykova, E. N.; Eremin, S. A.; Ermolaeva, T. N. // Journal of Analytical Chemistry;Jul2006, Vol. 61 Issue 7, p687 

    A mass-sensitive piezoelectric flow immunosensor for determining sulfo preparations in liquid media was proposed. This sensor included a piezoelectric quartz resonator with silver electrodes on the silanized surface of which sulfamethoxazole-protein conjugates were immobilized. The binding...

  • Permanent magnetic field sensor based on a piezoelectric ring. Krykanov, I. M.; Koplik, A. B.; Fetisov, Y. K.; Chashin, D. V. // Technical Physics Letters;Sep2010, Vol. 36 Issue 9, p838 

    We describe a permanent magnetic field sensor based on a radially polarized piezoelectric ring, with one electrode carrying alternating current. The device operation principle combines the Ampére force and piezoeffect. The magnetic sensor is characterized by a reduced responsivity of up to...

  • CHEMICAL SENSOR FOR THE DETERMINATION OF TOXIC SPECIES IN SOLUTION. Marie-Maurice, Marc; Essi, Meledge // Chalcogenide Letters;Jan2011, Vol. 8 Issue 1, p25 

    All solid state ion sensor based on a sensitive chalcogenide glass had been developed. The sensing membrane was characterised using electron microprobe analysis and X-ray thotoelectron spectroscopy. The analytical characteristics of CdS-AgI-Ag2S-As2S3 ISE were investigated and compared to the...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics