TITLE

Pyrolytic Carbon Resurfacing Arthroplasty for Osteoarthritis of the Proximal Interphalangeal Joint of the Finger

AUTHOR(S)
Sweets, Thomas M.; Stern, Peter J.
PUB. DATE
August 2011
SOURCE
Journal of Bone & Joint Surgery, American Volume;8/3/2011, Vol. 93-A Issue 15, p1417
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Background: Pyrolytic carbon resurfacing arthroplasty of the proximal interphalangeal joint has been reported to provide favorable results. The purpose of this study was to evaluate the effectiveness of pyrolytic carbon joint replacement at an average follow-up of fifty-five months. Methods: A retrospective review of thirty-one arthroplasties of the proximal interphalangeal joint performed by a single surgeon in seventeen patients with interphalangeal joint osteoarthritis was conducted. Assessment included range of motion, patient satisfaction, and pain scores. Radiographs were evaluated for alignment, implant subsidence, and implant failure. The Michigan Hand Outcomes Questionnaire was administered at the time of the final follow-up. Results: The average follow-up period was fifty-five months (minimum, two years). No patient was lost to follow-up. The arc of motion of the interphalangeal joint decreased from 57° preoperatively to 31°(p <0.05) at the time of the final follow-up. The average score for pain was 3 of 10 on a visual analog scale. Satisfaction averaged 3.4 points on a 5-point Likert scale, and twelve of seventeen patients stated that they would repeat the surgery. Data from the Michigan Hand Outcomes Questionnaire were compared for the involved and noninvolved hands of the fifteen patients who received implants unilaterally. Significant deficits were observed in the total outcome score, activities of daily living, function, and satisfaction for the operatively treated hand. Pain was also greater in the operatively treated hand. Complications included implant fracture (one joint), dislocation (five joints), squeaking (eleven), loosening (fifteen), and interphalangeal joint contracture (twenty). Six joints required a reoperation (an arthrodesis in four joints, a silicone arthroplasty in one, and excision of exostosis in one). Implant migration was severe for seven proximal phalanx implants and three distal phalanx implants, and one implant breached the phalangeal cortex. Conclusions: Interphalangeal joint motion decreased significantly at the final follow-up evaluation, following short-term gains in the initial postoperative period. Complications were numerous, and implant loosening with migration was a major problem. Arthroplasty of the proximal interphalangeal joint with a pyrolytic carbon implant has a high complication rate, poor outcomes, and variable patient satisfaction. On the basis of these findings, we no longer use this implant in our practice. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
ACCESSION #
64394838

 

Related Articles

  • An alternative method to create extramedullary references in total knee arthroplasty. Seo, Jai-Gon; Moon, Young-Wan; Park, Sang-Hoon; Shim, Jae-Woo; Kim, Sang-Min // Knee Surgery, Sports Traumatology, Arthroscopy;Jul2012, Vol. 20 Issue 7, p1339 

    Purpose: Historically, extramedullary techniques have focused on finding the femoral head center and referred mainly to the anterosuperior iliac spine (the FHC method) in total knee arthroplasty (TKA). The purpose of this study was to evaluate a new extramedullary alignment system that uses...

  • Anthropometry of the medial tibial condyle to design the tibial component for unicondylar knee arthroplasty for the Korean population. Surendran, Sibin; Kwak, Dai; Lee, U.; Park, Sang; Gopinathan, Patinharayil; Han, Seung; Han, Chang // Knee Surgery, Sports Traumatology, Arthroscopy;May2007, Vol. 15 Issue 4, p436 

    Unicondylar knee arthroplasty (UKA) has gained popularity in the recent years for treating medial compartment osteoarthritis of the knee joint in the Asian population. There is little information about the anthropometry of the resected bony surfaces of the knee joint in these population groups...

  • The effect of different design concepts in lumbar total disc arthroplasty on the range of motion, facet joint forces and instantaneous center of rotation of a L4-5 segment. Schmidt, Hendrik; Midderhoff, Stefan; Adkins, Kyle; Wilke, Hans-Joachim // European Spine Journal;Dec2009, Vol. 18 Issue 11, p1695 

    Although both unconstrained and constrained core lumbar artificial disc designs are in clinical use, the effect of their design on the range of motion, center of rotations, and facet joint forces is not well understood. It is assumed that the constrained configuration causes a fixed center of...

  • The Economics of New Age Arthroplasty: Can We Afford It? Sculco, Thomas P. // Orthopedics;Sep2006, Vol. 29 Issue 9, p782 

    The article offers views regarding the economics of new age arthroplasty. It discusses several factors affecting the cost of arthroplasty such as computer-assisted navigation joint replacement and high-flex knee designs. It addresses the need to reduce implant costs and generic implants of...

  • Radial Head Arthroplasty with a Modular Metal Spacer to Treat Acute Traumatic Elbow Instability. Doornberg, Job N.; Parisien, Robert; van Duijn, P. Joppe; Ring, David // Journal of Bone & Joint Surgery, American Volume;May2007, Vol. 89-A Issue 5, p1075 

    Background: The use of a metal radial head prosthesis to help stabilize an elbow with traumatic instability is appealing because internal fixation of multifragment, displaced fractures of the radial head is susceptible to either early or late failure. The newer modular prostheses are easier to...

  • Chromosomal Aberrations in the Peripheral Blood of Patients with Metal-on-Metal Hip Bearings. Dunstan, E.; Ladon, D.; Whittingham-Jones, P.; Carrington, R.; Briggs, T. W. R. // Journal of Bone & Joint Surgery, American Volume;Mar2008, Vol. 90-A Issue 3, p517 

    Background: Approximately one-third of patients undergoing joint replacement are under sixty years of age. Many of these patients may be exposed to wear debris from the orthopaedic implant for several decades. Clinical follow-up of this group of patients has been short compared with the...

  • Survival of Polished Compared with Precoated Roughened Cemented Femoral Components. Lachiewicz, Paul F.; Kelley, Scott S.; Soileau, Elizabeth S. // Journal of Bone & Joint Surgery, American Volume;Jul2008, Vol. 90-A Issue 7, p1457 

    Background: The optimal surface finish for cemented femoral components remains controversial. The purpose of this randomized clinical trial was to compare the survival of two femoral components with similar geometry but substantially different surface finishes. Methods: During a five-year...

  • Unicondylar Arthroplasty: Redefining Itself. Scott, Richard D. // Orthopedics;Sep2003, Vol. 26 Issue 9, p951 

    The article discusses unicondylar knee arthroplasty (UKA) as a treatment option for selected patients with unicompartmental osteoarthritis. The treatment has been in use since 1970 but its use has been controversial for the past three decades. It states that unicondylar knee arthroplasty is in...

  • Total disc replacement arthroplasty using the AcroFlex lumbar disc: a non-human primate model Total disc replacement arthroplasty. Cunningham, Bryan W.; Lowery, Gary L.; Serhan, Hassan A.; Dmitriev, Anton E.; Orbegoso, Carlos M.; McAfee, Paul C.; Fraser, Robert D.; Ross, Raymond E.; Kulkarni, Samir S. // European Spine Journal;Oct2002 Supplement 2, Vol. 11, pS115 

    Using a non-human primate model, the current study was undertaken to investigate the efficacy of the AcroFlex lumbar disc as an intervertebral disc prosthesis, based on biomechanical, histopathologic and histomorphometric analyses. A total of 20 mature male baboons (Papio cynocephalus, mean...

Share

Read the Article

Courtesy of VIRGINIA BEACH PUBLIC LIBRARY AND SYSTEM

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics