TITLE

Experimental Study on Indoor Thermal Stratification in Large Space by under Floor Air Distribution System (UFAD) in Summer

AUTHOR(S)
Xin Wang; Chen Huang; Weiwu Cao; Xuelei Gao; Wen Liu
PUB. DATE
April 2011
SOURCE
Engineering;Apr2011, Vol. 3 Issue 4, p384
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
A ventilation method of down-supply up-return has grown popular in large space in recent years for comfort ventilation with low thermal load, especially in China, including gymnasium, factory space, and exhibition hall, etc. The undisturbed flow pattern in the space gives a gradient in temperature, and the vertical thermal stratification appears markedly in large space. The object for this paper is to understand the behaviour of an under floor air distribution system in a ventilated space. The thermal stratification characteristics in a real UFAD experimental space were measured. The effects of different supply conditions on the thermal stratification characteristics are investigated based on the experimental results. The relations between space air stratification and the control parameter is predicted. It can be indicated that there are 4 zones composing the vertical thermal stratification. And different zone has different control parameter.
ACCESSION #
63802015

 

Related Articles

  • Human Response to an Individually Controlled Microenvironment. Melikov, A. K.; Knudsen, G. L. // HVAC&R Research;Jul2007, Vol. 13 Issue 4, p645 

    The response of 48 subjects to an individually controlled microenvironment was studied at room air temperatures of 20�C, 22�C, and 26�C. An individually controlled system (ICS) comprising personalized ventilation, an under-desk air terminal device supplying cool air, a chair with...

  • Simplified Model of Contaminant Dispersion in Rooms Conditioned by Chilled-Ceiling Displacement Ventilation System. Kanaan, M.; Ghaddar, N.; Ghali, K. // HVAC&R Research;Nov2010, Vol. 16 Issue 6, p765 

    The aim of this paper is to develop and experimentally validate a simplified model to predict carbon dioxide transport and distribution in rooms conditioned by chilled-ceiling displacement ventilation (CC/DV) system for known supply thermal and flow conditions and chilled-ceiling temperature....

  • Performance Comparison of Conventional and Chilled Ceiling/Displacement Ventilation Systems in Kuwait. Bahman, Ammar; Saade, Ralph; Chakroun, Walid; Ghali, Kamel; Ghaddar, Nesreen // ASHRAE Transactions;2009, Vol. 115 Issue 1, p587 

    This paper studies by experimentation and modeling the use and performance of cooled ceiling and displacement ventilation (CC/DV) systems to buildings in Kuwait for the purpose of assessing added value in satisfying comfort at high indoor air quality and opportunities of energy savings in...

  • Tech Talk.  // TAB Journal;2010, p14 

    The article presents questions and answers related to airflow tolerance and return balancing including the standard variations in airflow design, the tolerances listed in the Associated Air Balance Council (AABC) national standards on the minimum outside air (OSA), and the restriction of return air.

  • A Holistic Approach to Airflow Measurements in Clean-Rooms. Govier, J. // Medical Device Technology;Jan/Feb2007, Vol. 18 Issue 1, p30 

    How and when to accurately measure airflow are important issues in achieving optimum efficiency in a clean room. This article describes the equipment to use, the pros and cons of those methods and adds to the current debate over frequency of measuring.

  • Investigation of Airflow Patterns Inside Tall Building. Khoukhi, Maatouk // Recent Patents on Engineering;Jan2009, Vol. 3 Issue 1, p65 

    The total pressure difference acting on a building as a result of stack action depends upon building height and the difference between temperatures inside and outside. It cannot be avoided, but the way in which it is distributed across the building enclosure and interior separations can be...

  • Nearly zero energy office building without conventional heating. Thalfeldt, Martin; Kurnitski, Jarek; Mikola, Alo // Estonian Journal of Engineering;Dec2013, Vol. 19 Issue 4, p309 

    A case study of the first nearly zero energy office building (nZEB) in Rakvere, Estonia was conducted to determine whether an office building can be built without a conventional space heating system while ensuring adequate thermal comfort in the offices. Energy and indoor climate simulations of...

  • A Fuzzy Inference System Prototype for Indoor Air and Temperature Quality Monitoring and Hazard Detection.  // Journal of Environmental Informatics;Dec2010, Vol. 16 Issue 2, p70 

    No abstract available.

  • Minimum Outdoor Airflow Using the IAQ Procedure. Stanke, Dennis // ASHRAE Journal;Jun2012, Vol. 54 Issue 6, p26 

    The article discusses the measurement of the minimum outdoor airflow (OA) with the use of the indoor air quality procedure (IAQP). It provides the instructions to get the right measurement considering the contaminant sources, design approach, and contaminant concentration. It notes the...