ABSTRACT
The application of high intensity laser-produced gamma rays is discussed with regard to picosecond resolution deep-penetration radiography. The spectrum and angular distribution of these gamma rays is measured using an array of thermoluminescent detectors for both an underdense (gas) target and an overdense (solid) target. It is found that the use of an underdense target in a laser plasma accelerator configuration produces a much more intense and directional source. The peak dose is also increased significantly. Radiography is demonstrated in these experiments and the source size is also estimated.
ACCESSION #
6358326

 

Related Articles

  • Carrier-envelope Phase Drift Detection of Picosecond Pulses. Börzsönyi, A.; Jójárt, P.; Chiche, R.; Soskov, V.; Zomer, F.; Cormier, E.; Osvay, K. // EPJ Web of Conferences;2013, Issue 41, p11010-p.1 

    A bandwidth-independent, linear and scalable method for carrier-envelope phase drift measurement demonstrated. Our experiments reveal that carrier-envelope phase drift of a picosecond pulse train can be directly obtained from the spectrally resolved interference pattern of a length-stabilized...

  • Quantitative evaluation of single-shot inline phase contrast imaging using an inverse compton x-ray source. Oliva, P.; Carpinelli, M.; Golosio, B.; Delogu, P.; Endrizzi, M.; Park, J.; Pogorelsky, I.; Yakimenko, V.; Williams, O.; Rosenzweig, J. // Applied Physics Letters;9/27/2010, Vol. 97 Issue 13, p134104 

    Inverse compton scattering (ICS) x-ray sources are of current interest in biomedical imaging. We present an experimental demonstration of inline phase contrast imaging using a single picosecond pulse of the ICS source located at the BNL Accelerator Test Facility. The phase contrast effect is...

  • Picosecond OPO produces high-power transform-limited pulses.  // Laser Focus World;Feb95, Vol. 31 Issue 2, p13 

    Describes a tunable, high-repetition rate source of high-power picosecond pulses. Specifications and capabilities.

  • Pulse broadening in femtosecond x-ray diffraction. Tomov, I.V.; Chen, P.; Rentzepis, P.M. // Journal of Applied Physics;5/15/1998, Vol. 83 Issue 10, p5546 

    Provides information on a study analyzing the Bragg diffraction of subpicosecond x-ray pulses. Methodology used to conduct the study; Examination of the finite size of the x-ray beam; What the Bragg diffraction of ultrashort pulses was found to be accompanied with; Results of study.

  • Determination of Platinum-Group Elements and Gold in Silicates by Gamma Activation Autoradiography and Instrumental Gamma Activation Analysis. Kolotov, V. P.; Andriyanov, A. Yu.; Dogadkin, N. N.; Shilobreeva, S. N.; Chapyzhnikov, B. A.; Tsipenyuk, Yu. M.; Korobkov, V. I. // Journal of Analytical Chemistry;Sep2003, Vol. 58 Issue 9, p882 

    The potential of the gamma activation determination of platinum-group elements and gold both by instrumental gamma activation analysis (bulk analysis) and by monitoring their distribution using autoradiography (local analysis) is studied. It is shown that platinum-group elements and gold can be...

  • Design concepts for compact mass/energy charge exchange analyzers. Roquemore, A. L.; Medley, S. S. // Review of Scientific Instruments;Aug1986, Vol. 57 Issue 8, p1797 

    Charge exchange diagnostics in a hostile neutron and gamma radiation environment require substantial shielding against radiation-induced noise signal. Minimizing the dimensions of the apparatus significantly reduces the shielding complexity. Conceptual designs for compact analyzers are...

  • Improvements in the Image Quality of Neutron Radiograms of NUR Neutron Radiography Facility by Using Several Exposure Techniques. Zergoug, T.; Nedjar, A.; Mokeddem, M. Y.; Mammou, L. // AIP Conference Proceedings;3/17/2008, Vol. 989 Issue 1, p187 

    Since the construction of NUR reactor neutron radiography facility in 1991, only transfer exposure method was used as a non destructive technique. The reason is the excess of gamma rays in the neutron beam. To improve radiation performances of the NR system, a stainless steal hollow conical...

  • PLEIADES: A picosecond Compton scattering x-ray source for advanced backlighting and time-resolved material studies. Gibson, David J.; Anderson, Scoff G.; Barty, Christopher P. J.; Betts, Shawn M.; Booth, Rex; Brown, Winthrop J.; Crane, John K.; Cross, Robert R.; Fittinghoff, David N.; Hartemann, Fred V.; Kuba, Jaroslav; Le Sage, Gregory P.; Slaughter, Dennis R.; Tremaine, Aaron M.; Wootton, Alan J.; Hartouni, Edward P.; Springer, Paul T.; James B. Rosenzweig // Physics of Plasmas;May2004, Vol. 11 Issue 5, p2857 

    The PLEIADES (Picosecond Laser-Electron Inter-Action for the Dynamical Evaluation of Structures) facility has produced first light at 70 keV. This milestone offers a new opportunity to develop laser-driven, compact, tunable x-ray sources for critical applications such as diagnostics for the...

  • Resistance of Proton-Irradiated GaAs Photodetectors to Combined Gamma and Neutron Radiation. Murel, A.V.; Obolenski&icaron, S.V.; Fefelov, A.F.; Kiseleva, E.V. // Semiconductors;Jul2004, Vol. 38 Issue 7, p800 

    Characteristics of proton-irradiated epitaxial i-GaAs structures with an interdigitated system of electrodes are studied before and after exposure to combined γ and neutron radiation. In order to reduce the dark current of photodetectors, the electrodes were metallized on proton-irradiated...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics