TITLE

SPARTUVIX I1' An improved x-ray ultraviolet spectrograph with temporal and spatial capabilities for indirect drive inertial confinement fusion experiments (abstract)

AUTHOR(S)
Bourgade, J. L.; Guilly, E.; Bruneau, J.; Gary, S.; Gontier, D.; Renaudin, P.; Reverdin, C.; Thiell, G.; Eldmann, K.; Winhart, G.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p1064
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes the development of an improved version of the initial x-ray ultraviolet spectrograph SPARTUVIX to record the time evolution of spatially resolved spectra in the soft x-ray range. Applications of the diagnostic; Spatial resolution; Imaging system.
ACCESSION #
630922

 

Related Articles

  • ALS Beamline 6.0 For Ultrafast X-ray Absorption Spectroscopy. Heimann, P. A.; Padmore, H. A.; Schoenlein, R. W.; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p1407 

    ALS Beamline 6.0 is designed for x-ray absorption spectroscopy with femtosecond x-ray pulses generated by the bunch ‘slicing’ technique. The fs x-ray pulses are isolated by imaging the source and translating slits a small vertical distance from the optical axis. Soft and hard x-ray...

  • Spectrograph's first light traveled 10 billion years. Savage, Neil // Laser Focus World;Sep99, Vol. 35 Issue 9, p40 

    Focuses on the Macario Low-Resolution Spectrograph (LRS). First observation made by the LRS; How the LRS works; Possible configurations of the device.

  • A single-shot spectrograph for the soft x-ray region. Jasny, J.; Teubner, U.; Theobald, W.; Wülker, C.; Bergmann, J.; Schäfer, F. P. // Review of Scientific Instruments;May94, Vol. 65 Issue 5, p1631 

    A novel spectrograph comprised of a transmission grating, toroidal mirror, and microchannel plate detector is presented here. It is capable of detecting spectra in the wavelength range from 5 to 150 Ã… with a resolution of about 1.5 Ã…. Owing it to high efficiency, even an x-ray spectrum...

  • Super ESCA: First beamline operating at ELETTRA. Abrami, A.; Barnaba, M.; Battistello, L.; Bianco, A.; Brena, B.; Cautero, G.; Chen, Q.H.; Cocco, D.; Comelli, G.; Contrino, S.; DeBona, F.; Di Fonzo, S.; Fava, C.; Finetti, P.; Furlan, P.; Galimberti, A.; Gambitta, A.; Giuressi, D.; Godnig, R. // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1618 

    Describes the Super-ESCA, a beamline designed for high resolution core level spectroscopy of adsorbates on single crystal surfaces using soft x-ray synchrotron radiation. Light source; Scheme of the stigmatic SX700 monochromator; Resolution measurements.

  • Computer control of the SRC high-resolution beamline. Eisert, David E.; Bissen, Mark; Fisher, Mike V.; Reininger, Ruben; Stott, John P.; Hochst, Hartmut // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p1671 

    Discusses the complexities of controlling via computer the high-resolution soft x-ray beamline at the University of Wisconsin Synchrotron Radiation Center. Computer controls; Monochromator assembly; Rotational and translational motion; Calculation of positions; Software.

  • Investigation of the radiation properties of L- and M-shell X-pinch plasma x-ray sources using a transmission grating spectrometer. Fedin, D. A.; Kantsyrev, V. L.; Shlyaptseva, A. S.; Mitchell, M. D.; Song, B. M.; Pikuz, S. A.; Shelkovenko, T. A.; Chandler, K. M.; Hammer, D. A.; Maxson, L. M. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3711 

    A transmission grating spectrometer (TGS) with one dimensional spatial resolution was used to investigate the radiative properties of X-pinch plasmas produced using wires made of NiCr and CoNiCr alloys, and Mo. Experiments were carried out on the Cornell XP machine. The TGS was used to estimate...

  • Beamline upgrade from PGM (SX700-type) to varied-line-space PGM at CAMD. Ono, Masaki; Scott, John D.; Morikawa, Eizi; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p360 

    A varied-line-space plane-grating monochromator for the energy range of 200 – 1,200 eV is described as an upgrade of the CAMD plane-grating monochromator. Ray-tracing calculations indicate performance improvements in both resolving power and throughput. An increase in resolving power from...

  • VLS-PGM Beamline at the Canadian Light Source. Hu, Y. F.; Zuin, L.; Reininger, R.; Sham, T. K. // AIP Conference Proceedings;2007, Vol. 879 Issue 1, p535 

    The Variable Line Spacing Plane Grating Monochromator (VLS-PGM) beamline is one of the several soft X-ray beamlines at the Canadian Light Source (CLS). It is designed to produce photons ranging from 5.2 to 250 eV with a resolving power of 10,000. It uses a 185 mm period length Planar Permanent...

  • A simple method for overcoming spatial resolution limitations in soft x-ray spectrograph/detector systems. MacGowan, B. J.; Koch, J. A.; Mrowka, S. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p5122 

    We describe a simple method for improving the spectral resolution of soft x-ray and extreme ultraviolet spectrographs which use electro-optical detector/intensifiers. In this method, the spectrometer is focused onto a narrow slit which is angled near 90° with respect to the dispersive axis...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics