TITLE

Multilayer mirror based line emission tomography for spherical Tokamaks

AUTHOR(S)
Stutman, D.; Hwang, Y. S.; Menard, J.; Choe, W.; Ono, M.; Finkenthal, M.; May, M. J.; Regan, S. P.; Soukhanovskii, V.; Moos, H. W.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p1055
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Develops arrays of high throughput mini-monochromators using extreme ultraviolet multilayer mirrors (MLM) as dispersive elements and filtered surface barrier diodes as detectors. Utility of the device in collecting data required for tomographic reconstruction of local emissivities in spherical tokamaks; Increased use of MLM-based spectroscopic system as fusion plasma diagnostics.
ACCESSION #
630918

 

Related Articles

  • Effects of neutron on semiconductor x-ray detectors including n-type Joint European Torus and... Cho, T.; Kohagura, J.; Hirata, M.; Sakamoto, Y.; Nakamura, T.; Minami, R.; Sasuga, T.; Nishizawa, Y.; Okamura, T.; Tamano, T.; Yatsu, K.; Miyoshi, S.; Hirano, K.; Maezawa, H. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p577 

    Investigates the effects of fusion-produced neutrons on the x-ray responses of semiconductor detectors for x-ray tomography in the Joint European Torus tokamak and the GAMMA 10 tandem mirror. Neutron effects on the x-ray energy responses; Investigation of the changes in the material properties...

  • Soft x-ray tomography diagnostic for the Alcator C tokamak. Camacho, J. F.; Granetz, R. S. // Review of Scientific Instruments;Mar86, Vol. 57 Issue 3, p417 

    A soft x-ray tomography diagnostic has been built and operated on the Alcator C tokamak with the use of an 80-channel array of detectors. The detector system consists of miniature PIN photodiodes which are located around the periphery of the plasma at one toroidal location (top and bottom ports)...

  • AXUV bolometer and Lyman-α camera systems on the TCV tokamak. Degeling, A. W.; Weisen, H.; Zabolotsky, A.; Duval, B. P.; Pitts, R. A.; Wischmeier, M.; Lavanchy, P.; Marmillod, Ph.; Pochon, G. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p4139 

    A set of seven twin slit cameras, each containing two 20-element linear absolute extreme ultraviolet photodiode arrays, has been installed on the Tokamak à Configuration Variable. One array in each camera will operate as a bolometer and the second as a Lyman-alpha (Lα) emission monitor for...

  • Optimization of a focusing monochromator. Mergia, K.; Messoloras, S. // Review of Scientific Instruments;Feb2003, Vol. 74 Issue 2, p931 

    The procedure for optimizing the performance of a focusing monochromator using a linear position sensitive detector is described. Analytical expressions describing the reflected beam profile are derived. The methodology for deriving the calibration function of the focusing device and its...

  • Direct Measurement of the Resolving Power of X-ray CT System in SPring-8. Uesugi, Kentaro; Suzuki, Yoshio; Takano, Hidekazu; Tamura, Shigeharu; Kamijo, Nagao; Yagi, Naoto; Warwick, T. // AIP Conference Proceedings;2004, Vol. 705 Issue 1, p1316 

    Resolving power of high spatial resolution X-ray computed tomography (CT) system was evaluated by taking CT images of artificial test patterns at BL47XU in SPring-8 (SP-μCT BL47XU). The system consists of an in-vacuum type undulator, a double crystal monochromator cooled with liquid nitrogen,...

  • Comparison of elliptical and spherical mirrors for the grasshopper monochromators at SSRL. Waldhauer, A. P. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2109 

    A comparison of the performance of a spherical and elliptical mirror in the grasshopper monochromator is presented. The problem was studied by ray tracing and then tested using visible (λ = 633 nm) laser light. Calculations using ideal optics yield an improvement in flux by a factor of up to...

  • First tomographic reconstructions and a study of interference filters for visible-light... Ingesson, L.C.; Pickalov, V.V.; Donne, A.J.H.; Schram, D.C. // Review of Scientific Instruments;Jan1995, Vol. 66 Issue 1, p622 

    Describes an 80-channel visible-light tomography diagnostic on the Rijnhuizen Tokamak Project in the Netherlands. Use of optical imaging systems from five different directions; Demonstration of a consistent treatment in the tomographic reconstructions.

  • A variable radius mirror for imaging the exit slit of a spherical grating monochromator undulator... Warwick, Tony; Howells, Malcolm; Shlezinger, Meir // Review of Scientific Instruments;Feb1995, Vol. 66 Issue 2, p2270 

    Describes bendable metal mirrors that were implemented in two spherical grating monochromator (SGM) undulator beamlines at the Advanced Light Source in Berkeley, California. Use of a piezoelectric actuator to deform the mirror to image the SGM exit slit; Comparison of computed deformations and...

  • High resolution monochromatic tomography with x-ray sensing pickup tube. Hirano, Tatsumi; Usami, Katsuhisa; Sakamoto, Kozoo // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2482 

    Using monochromatic synchrotron radiation and a high resolution x-ray sensing pickup tube as a two-dimensional detector, we have improved the spatial resolution of x-ray computed tomographic (CT) images. A quantitative elemental analysis was made based on the difference between two CT images...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library