TITLE

Diagnostics for local spectroscopic measurements in the divertor region of the Alcator C- Mod and DIII-D tokamaks

AUTHOR(S)
May, M. J.; Regan, S. P.; Soukhanovskii, V. A.; Finkenthal, M.; Moos, H. W.; Goetz, J. A.; Lipschultz, B.; Terry, J. L.; West, P.; Allen, S.; Brooks, N.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p1047
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Addresses the problems associated with extracting local signals of spectral line emissions from impurities in the divertor region of the tokamak and presents the design and implementation of the soft x-ray and extreme ultraviolet (XUV) Periscope. Spatial resolution of the XUV Periscope; Photodetectors.
ACCESSION #
630916

 

Related Articles

  • How to beat the low resolution of multilayer mirror spectra (invited) Regan, S. P.; Fournier, K. B.; May, M. J.; Soukhanovskii, V.; Finkenthal, M.; Moos, H. W. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p1002 

    Illustrates how atomic physics modeling can be used to extract the soft x-ray and extreme ultraviolet (XUV) spectral line brightnesses measured with low-resolution, high-photon-throughput, multilayer mirror (MLM)-based devices. Overview of MLM-based devices; XUV radiation of low Z impurities;...

  • The design and optimization of recombination extreme-ultraviolet lasers. Epstein, R. // Physics of Fluids B: Plasma Physics;Jan89, Vol. 1 Issue 1, p214 

    Recent evidence for amplification of the Balmer-alpha line of hydrogenlike carbon in a recombining plasma [Opt. Commun. 54, 289 (1985)] raises the question of the relative importance of radiative cooling in this experiment and of the role of radiative cooling in optimizing future experiments....

  • SCIENCE WITH SOFT X RAYS. Smith, Neville // Physics Today;Jan2001, Vol. 54 Issue 1, p29 

    Focuses on several science experiments conducted using the soft x-rays and vacuum ultraviolet (VUV) region of the spectrum. High spatial-resolution microscopy; Photoelectron microscopy; Spectral resolution and electronic structure.

  • The JET soft x-ray diagnostic systems Alper, B.; Dillon, S.; Edwards, A. W.; Gill, R. D.; Robins, R.; Wilson, D. J. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p778 

    Describes the construction of a multicamera soft x-ray (SXR) detector system for the pumped divertor phase of the Joint European Torus tokamak to provide improved spatial and temporal resolution. Features of the SXR camera assemblies; Detector performance tests; Operational experience and...

  • VUV-SX spherical grating monochromator for BEPC beamline 4B9B. Shu, D.; Wang, W.; Liu, W.; Zhang, Y.; Wang, M.; Liu, J.; He, W.; Cong, Z.; Xie, Q. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p2085 

    The BEPC beamline 4BgB is intended for VUV-SX photoelectron spectroscopy and other soft xray applications. The beamline optical system consists of a focusing mirror system and a VUV-SX spherical grating monochromator with four gratings, which cover a large spectral range 10-1100 eV. Three...

  • Status of insertion device and beamline design for ELETTRA. Rosei, R.; Walker, R. P. // Review of Scientific Instruments;Jul1989, Vol. 60 Issue 7, p1809 

    ELETTRA is a new ultrahigh-brightness VUV/soft x-ray synchrotron radiation facility under construction by Sincrotrone Trieste in Italy. The main features of the project and its status are described. Details of the expected properties of the different types of radiation source are presented, and...

  • B/Si multilayers for soft x-ray and extreme ultraviolet optics. Ravet, M. F.; Bridou, F.; Raynal, A.; Pardo, B.; Chauvineau, J. P.; AndrĂ©, J.-M. // Journal of Applied Physics;1/15/2001, Vol. 89 Issue 2, p1145 

    With the development of x-ray sources, high reflectivity and selectivity multilayers for optics are becoming a field of interest for the spectral region of 13-40 nm. In this article, it is shown from theoretical computations that multilayers made of two light materials such as B/Si can be used...

  • Soft x-ray tomography diagnostic for the Alcator C tokamak. Camacho, J. F.; Granetz, R. S. // Review of Scientific Instruments;Mar86, Vol. 57 Issue 3, p417 

    A soft x-ray tomography diagnostic has been built and operated on the Alcator C tokamak with the use of an 80-channel array of detectors. The detector system consists of miniature PIN photodiodes which are located around the periphery of the plasma at one toroidal location (top and bottom ports)...

  • Toroidal and poloidal soft x-ray imaging system on the DIII-D tokamak. Snider, R. T.; Evanko, R.; Haskovec, J. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1807 

    A toroidal soft x-ray imaging system is being added to the currently installed poloidal soft x-ray system on the DIII-D tokamak. The poloidal array is used to determine the poloidal mode structure and location of internal helical MHD perturbations in the plasma. The new array will add toroidal...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics