TITLE

Measurements of ZeFF spatial profiles from bremsstrahlung emission in the visible and near infrared spectral region

AUTHOR(S)
Orsitto, F.; Belforte, M. R.; Borra, M.; Brusadin, A.; Giovannozzi, E.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p1024
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Discusses the measurement of plasma radiation in the infrared range at six lines of sight from z equal to -20 centimeters to z equal to eight centimeters above the equatorial plane, using the detection system of the Frascati Tokamak Upgrade Thomson scattering system. Comparison of plasma emission measurements; Determination of the gaunt factor.
ACCESSION #
630909

 

Related Articles

  • Avalanche photodiodes operating parameter optimization for the Frascati Tokamak Upgrade Thomson... Orsitto, F.; Brusadin, A.; Giovannozzi, E. // Review of Scientific Instruments;Feb1997, Vol. 68 Issue 2, p1201 

    Analyzes the avalanche photodiodes operating parameter optimization of the Frascati Tokamak Upgrade Thomson scattering system. Measurement of the plasma radiation in the near-infrared spectral region; Determination of the ultimate signal-to-noise ratio achievable.

  • Measurement of Zeff profiles from bremsstrahlung emission in the near infrared. Röhr, H.; Steuer, K. H.; the ASDEX Team // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1875 

    Local measurements of plasma radiation in the near infrared using the detection system of the ASDEX Thomson scattering device are reported. Comparison with hydrogen bremsstrahlung yields Z[sub eff] profiles. Good agreement with values from other diagnostics is obtained. Z[sub eff] behavior in a...

  • Apparatus for multipoint Thomson scattering measurements in the ETA-BETA II reversed field pinch experiment. Bassan, M.; Buffa, A.; Giudicotti, L. // Review of Scientific Instruments;May85, Vol. 56 Issue 5, p1027 

    A multipoint Thomson scattering apparatus under development for the measurement of spatial T[sub e] and n[sub e] profiles in the ETA-BETA II reverse field pinch experiment is described. The apparatus is based upon the two-channel analysis method already adopted in the TFR tokamak. The 90°...

  • A compact Thomson scattering system Dimock, D.; Grek, B.; Johnson, D.; LaBombard, B.; Lipschultz, B.; McCracken, G. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p700 

    Describes the construction and installation of a multipulse Neodymium:YAG Thomson scattering system for measuring electron temperature and density profiles in the throat of the divertor of the Alcator C-Mod tokamak. Input optics; Fiber optics; Polychromator; Detectors and electronics; Laser...

  • High-resolution edge Thomson scattering measurements on the Alcator C-Mod tokamak. Hughes, J. W.; Mossessian, D. A.; Hubbard, A. E.; Marmar, E. S.; Johnson, D.; Simon, D. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p1107 

    A high-resolution Thomson scattering diagnostic is in operation on the Alcator C-Mod tokamak, measuring radial profiles of electron temperature and density at the plasma edge. Photons are scattered from a Nd–yttrium–aluminum–garnet laser beam pulsed at 30 Hz (1.3 J, 8 ns...

  • Initial operation of the divertor Thomson scattering diagnostic on DIII-D. Carlstrom, T.N.; Hsieh, C.L.; Stockdale, R.; Nilson, D.G.; Hill, D.N. // Review of Scientific Instruments;Feb1997, Vol. 68 Issue 2, p1195 

    Details the commissioning of the divertor Thomson scattering (DTS) system for the DIII-D tokamak. Achievement of two-dimensional mapping of the divertor region; Measurement of the scattered and plasma background light; Schematic layout of the DTS diagnostic.

  • Initial operation of the divertor Thomson scattering diagnostic on DIII-D (abstract) Carlstrom, T. N.; Hsieh, C. L.; Stockdale, R.; Nilson, D. G.; Hill, D. N. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p708 

    Presents an abstract of a paper reporting on Thomson scattering measurements in the divertor region of a tokamak. Use of the data as input to boundary physics codes such as UEDGE and DEGAS and to benchmark the predictive capabilities of the codes; Characterization of tokamak disruptions; Fiber...

  • Error analysis of Rijnhuizen tokamak project Thomson scattering data. Beurskens, M.N.A.; Barth, C.J.; Chu, C.C.; Lopes Cardozo, N.J. // Review of Scientific Instruments;Apr99, Vol. 70 Issue 4, p1999 

    Focuses on error analysis of Thomson scattering data at the Rijnhuizen tokamak project in the Netherlands. Overview of the Thomson scattering diagnostic; Error determination; Instrument profile; Convolution of the fit function.

  • Thomson scattering diagnostic for the microwave tokamak experiment. Foote, J. H.; Barter, J. D.; Sewall, N. R.; Jolly, J. J.; Schlander, L. F. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p2861 

    The Thomson scattering diagnostic system (TSS) on the microwave tokamak experiment (MTX) at LLNL routinely monitors electron temperature (T[sub e]) and density. Typical measured values at the plasma center under clean conditions are 900 ± 70 eV and 1-2 × 10[sup 14] (± 30%) cm[sup -3]....