TITLE

A fast charge coupled device detector for charge exchange recombination spectroscopy on the DIII-D Tokamak (abstract)

AUTHOR(S)
Thomas, D. M.; Burrell, K. H.; Groebner, R. J.; Gohil, P.; Kaplan, D.; Makariou, C.; Seraydarian, R. P.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p1019
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes a fast charge coupled device detector for charge exchange recombination (CER) spectroscopy on the DIII-D tokamak. Applications of CER measurements; Ability of the system to detect sufficient photons to utilize the shortest time resolution only under exceptional conditions.
ACCESSION #
630907

 

Related Articles

  • Improved charge-coupled device detectors for high-speed, charge exchange spectroscopy studies on the DIII-D tokamak. Burrell, K. H.; Gohil, P.; Groebner, R. J.; Kaplan, D. H.; Robinson, J. I.; Solomon, W. M. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3455 

    Charge exchange spectroscopy is one of the key ion diagnostics on the DIII-D tokamak. It allows determination of ion temperature, poloidal and toroidal velocity, impurity density, and radial electric field Er throughout the plasma. For the 2003 experimental campaign, we replaced the intensified...

  • A fast charge coupled device detector for charge exchange recombination spectroscopy on the... Thomas, D.M.; Burrell, K.H.; Groebner, R.J.; Gohil, P.; Kaplan, D.; Makariou, C.; Seraydarian, R.P. // Review of Scientific Instruments;Feb1997, Vol. 68 Issue 2, p1233 

    Presents a fast charge coupled detector (CCD) for charge exchange recombination (CER) spectroscopy on the DIII-D tokamak. Use of CER to determine spatially and temporally resolved ion temperature; Quantum efficiency of CCD; Improvement of data quality for measurements in the divertor-relevant...

  • Charge-coupled detector readout method for visible emission profiling of a tokamak discharge. Zurro, B.; Pacios, L. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p2946 

    A handy method and hardware for readout and display on a digital oscilloscope the repetitive visible emission profiles, obtained in the TJ-I tokamak with a standard linear charge-coupled detector, is presented. A detailed description of the electronics, alignment procedure, and detector...

  • The NSTX fast-ion D-alpha diagnostic. Podestà, M.; Heidbrink, W. W.; Bell, R. E.; Feder, R. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E521 

    A new diagnostic, aimed at energy-resolved measurements of the spatial and temporal dynamics of fast ions in NSTX plasmas, is described. It is based on active charge-exchange recombination spectroscopy. The fast-ion signal is inferred from light emitted in the wavelength range of the Dα line...

  • Charge-coupled device area x-ray detectors. Gruner, Sol M.; Tate, Mark W.; Eikenberry, Eric F. // Review of Scientific Instruments;Aug2002, Vol. 73 Issue 8, p2815 

    Charge-coupled device (CCD) area x-ray detector technology is reviewed. CCD detectors consist of a serial chain of signal components, such as phosphors, fiber optics or lenses, image intensifiers and the CCD which serve to convert the x-ray energy to light or electron-hole pairs and to record...

  • Single-event keV proton detection using a delta-doped charge-coupled device. Nikzad, Shouleh; Croley, Donald // Applied Physics Letters;10/25/1999, Vol. 75 Issue 17, p2686 

    Demonstrates an order-of-magnitude improvement in the low-energy cutoff for particle detection compared to conventional solid-state detectors using a delta-doped charge-coupled device (CCD). Detection of individual protons; Use of delta-doped CCD to determine the energy of the incoming particle.

  • An economical x-ray area detector based on an intensified CCD unit. Gao, Tong; Li, Yingjie; Rousseau, Jean; Linliu, Kung; Chu, Benjamin // Review of Scientific Instruments;Feb1993, Vol. 64 Issue 2, p390 

    An economical charge-coupled device (CCD) based area detector for x-ray experiments was developed and assembled. Although low in cost, careful evaluation shows that this detector consisting of an optical fiber taper, an image intensifier, a relay lens, and a cooled CCD unit has good overall...

  • Measurement of quantum efficiency of a charge coupled device Hashimotodani, K.; Toneri, T.; Toned, T.; Kitamoto, S.; Tsunemi, H.; Hayashida, K.; Miyata, E.; Ohtani, M.; Asakura, R.; Katayama, K.; Kohmura, T.; Hiraga, J.; Katayama, H.; Shoho, M.; Kinugasa, K.; Imayoshi, T.; Sumi, Y.; Ohono, Y. // Review of Scientific Instruments;Nov98, Vol. 69 Issue 11, p3746 

    Measures the quantum efficiency of a front-illuminated charge coupled device (CCD). Description of CCD; Details on the quantum efficiency for single pixel events and flux mode operation; Comparison with other solid state detectors; Presentation of quantum efficiency as a function of energy.

  • Sensitive CCDs see the light. Devlin, Sheena // Laser Focus World;Jul2002, Vol. 38 Issue 7, p61 