ABSTRACT
Discusses the use of fast charge-coupled device (CCD) detector arrays placed at the output of visible spectrometers for multichord Doppler shift analyses on the COMPASS-D and START tokamaks. Optics and spectrometer; CCD detector; Versatility of the instrument design both in terms of wavelengths and observable plasma phenomena.
ACCESSION #
630906

 

Related Articles

  • Design of a D-alpha beam-ion profile diagnostic. Luo, Y.; Heidbrink, W. W.; Burrell, K. H. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3468 

    Injected neutral beams ionize to create a population of beam ions. As they orbit around the tokamak and pass through the heating beams, some beam ions re-neutralize and emit D-alpha light. The intensity of this emission is weak compared to the signals from the injected neutrals, the warm (halo)...

  • X-ray crystal spectrometer with a charge-coupled-device detector for ion temperature measurements in the Large Helical Device. Morita, Shigeru; Goto, Motoshi // Review of Scientific Instruments;Apr2003, Vol. 74 Issue 4, p2375 

    A Johann-type x-ray crystal spectrometer has been designed using a ray tracing calculation and constructed for ion temperature measurement in the plasma center of a large helical device (LHD) using Doppler broadening of a He-like resonance line of ArXVII, TiXXI, CrXXIII, or FeXXV. Four curved...

  • Conical x-ray crystal spectrometer for time integrated and time resolved measurements. Andiel, U.; Eidmann, K.; Pisani, F.; Witte, K.; Uschmann, I.; Wehrhan, O.; Förster, E. // Review of Scientific Instruments;Apr2003, Vol. 74 Issue 4, p2369 

    We present a new x-ray spectrometer setup based on a conically curved mica crystal in the von Hamos configuration. An x-ray sensitive charge coupled device or streak camera can be easily coupled in a perpendicular orientation to the spectrally resolved x-ray line focus. Shifting the crystal...

  • Design and commissioning of a new diagnostic for routine determination of Zeff from visible bremsstrahlung measurements on TEXTOR. Verdoolaege, G.; Telesca, G.; Delabie, E.; Van Oost, G.; The TEXTOR Team // Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10F310 

    On TEXTOR a new diagnostic was commissioned for the determination of the profile of the ion effective charge Zeff from bremsstrahlung emissivity measurements in the visible. The line-integrated bremsstrahlung emissivity is measured with high spatial resolution along 28 fiber optic channels, in...

  • Monte Carlo simulation for the prediction of precision of absorbance measurements with a miniature CCD spectrometer. Tsaousoglou, E.P.; Bolis, S.D.; Efstathiou, C.E. // Journal of Automated Methods & Management in Chemistry;Mar/Apr2003, Vol. 25 Issue 2, p35 

    The precision characteristics of the absorbance measurements obtained with a low-cost miniature spectrometer incorporating an array detector were evaluated. Uncertainties in absorbance measurements were due to a combination of non-uniform light intensity and detector response over the wavelength...

  • Spectrometer Features Enhanced Efficiency, Low-noise Operation.  // Laboratory Equipment;Mar2014, Vol. 50 Issue 12, p26 

    The article offers brief information on the QE Pro back-thinned charge couple-device (CCD) array spectrometer from Ocean Optics Inc.

  • A new spectrometer using multiple gratings with a two-dimensional charge-coupled diode array detector. Han, Tao; Ni, Wei-Ming; Zhou, Peng; You, Hai-Yang; Jia, Jian-Hu; Wang, Song-You; Chen, Liang-Yao; Lynch, David W. // Review of Scientific Instruments;Jun2003, Vol. 74 Issue 6, p2973 

    A new spectrometer with no moving parts uses a two-dimensional Si-based charge-coupled diode (CCD) array detector and an integrated grating consisting of three subgratings. The effective spectral range imaged on the detector is magnified threefold. The digitized spectral image in the...

  • Design of an electronic charged particle spectrometer to measure (pr) on inertial fusion experiments Hicks, D. G.; Li, C. K.; Petrasso, R. D.; Seguin, F. H.; Burke, B. E.; Knauer, J.P.; Cremer, S.; Kremens, R. L.; CabLe, M.D.; Phillips, T. W. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p589 

    Discusses the design and fabrication of an electronic charged particle spectrometer to measure the energy spectra of charged particles from targets on the Omega Upgrade. Design of the magnet; Charge coupled devices; Energy resolution; Operating yield; Signal-to-noise; CR-39 track detectors.

  • A fast charge coupled device detector for charge exchange recombination spectroscopy on the... Thomas, D.M.; Burrell, K.H.; Groebner, R.J.; Gohil, P.; Kaplan, D.; Makariou, C.; Seraydarian, R.P. // Review of Scientific Instruments;Feb1997, Vol. 68 Issue 2, p1233 

    Presents a fast charge coupled detector (CCD) for charge exchange recombination (CER) spectroscopy on the DIII-D tokamak. Use of CER to determine spatially and temporally resolved ion temperature; Quantum efficiency of CCD; Improvement of data quality for measurements in the divertor-relevant...