TITLE

Signal processing and general purpose data acquisition system for on-line tomographic measurements

AUTHOR(S)
Murari, A.; Martin, P.; Hemming, O.; Manduchi, G.; Marrelli, L.; Taliercio, C.; Hoffmann, A.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p951
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes the development of analog signal conditioning electronics and data acquisition systems for the soft x-ray and bolometric tomography diagnostic in the reverse field pinch experiment. Signal processing analog electronics; Main tasks that the data acquisition system deals with; Software organization.
ACCESSION #
630891

 

Related Articles

  • Soft x-ray and bolometric tomography in RFX. Martin, P.; Murari, A.; Buffa, A.; Marrelli, L.; Baker, W.; Gadani, G.; Hemming, O.; Manduchi, G.; Parini, A.; Taliercio, C.; Hoffmann, A.; Stasek, G.; Wirth, R. // Review of Scientific Instruments;Feb1997, Vol. 68 Issue 2, p1256 

    Details the design of an eight-camera soft x-ray (SXR) and bolometric tomography which has been installed in RFX, a high-current reverse field pinch experiment operating in Padova, Italy. Reconstruction of SXR and total radiation emissivity structures; Inclusion of eight fully remotely...

  • Soft x-ray and bolometric tomography in RFX (abstract) Martin, P.; Murari, A.; Buffa, A.; Marrelli, L.; Baker, W.; Gadani, G.; Hemming, O.; Manduchi, G.; Parini, A.; Taliercio, C.; Hoffmann, A.; Stasek, G.; Wirth, R. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p761 

    Presents the design and the first results of an eight-camera soft x-ray and bolometric tomography which has been installed in RFX, a high current reverse field pinch experiment operating in Padova, Italy. Main features of the diagnostic; Components.

  • An optimized multifoil soft x-ray spectrometer for the determination of the electron temperature... Murari, A.; Franz, P.; Zabeo, L.; Bartimoro, R.; Carraro, L.; Gadani, G.; Marrelli, L.; Martin, P.; Pasqualotto, R.; Valisa, M. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p581 

    Describes the design and operation of an optimized, multifoil soft x-ray spectrometer for the determination of the electron temperature with high time resolution in reversed field pinch. Components of the system; Measured values of the electron temperature and its correlation with main plasma...

  • A new double-foil soft x-ray array to measure Te on the MST reversed field pinch. McGarry, M. B.; Franz, P.; Den Hartog, D. J.; Goetz, J. A. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E516 

    A soft x-ray (SXR) diagnostic to measure electron temperature on the Madison Symmetric Torus using two complementary methods is presented. Both methods are based on the double-foil technique, which calculates electron temperature via the ratio of SXR bremsstrahlung emission from the plasma in...

  • Tangential soft-x ray imaging for three-dimensional structural studies in a reversed field pinch. Onchi, T.; Ikezoe, R.; Oki, K.; Sanpei, A.; Himura, H.; Masamune, S. // Review of Scientific Instruments;Jul2010, Vol. 81 Issue 7, p073502 

    Tangential soft-x ray (SXR) imaging diagnostic has been developed and three-dimensional (3D) structure of the internal magnetic surface has been deduced by comparing the experimental and calculated two-dimensional SXR images in a reversed field pinch. The SXR imaging system, consisting of a MCP,...

  • Compact soft x-ray multichord camera: Design and initial operation. Franz, P.; Gadani, G.; Pasqualotto, R.; Marrelli, L.; Martin, P.; Spizzo, G.; Brunsell, P.; Chapman, B. E.; Paganucci, F.; Rossetti, P.; Xiao, C. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p2152 

    A compact and low cost diagnostic for spatially resolved measurements of soft x-ray or total radiation emission has been designed and realized to be flexibly applied to different plasma physics experiments. Its reduced size (outer diameter=35 mm) makes it suited to a variety of devices. The line...

  • Measurement of electron transport in the Madison Symmetric Torus reversed-field pinch (invited). Lanier, N. E.; Craig, D.; Anderson, J. K.; Biewer, T. M.; Chapman, B. E.; Den Hartog, D. J.; Forest, C. B.; Prager, S. C.; Brower, D. L.; Jiang, Y. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p1039 

    A recent study investigating the role of electron density fluctuations in particle transport has been conducted on the Madison Symmetric Torus reversed-field pinch. Four diagnostics enabled this experiment: a high-speed multichord far-infrared laser interferometer, a multichord Hα array, a...

  • A new linear amplifier for the RFX electron energy analyzer. Desideri, D.; Bagatin, M. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p407 

    Describes the development of a simple low cost novel linear amplifier for the electron energy analyzer employed on the reversed field pinch experiment (RFX). Circuit design; Location of the amplifier; Reliability of the instrument.

  • Production of superthermal electrons and ion cyclotron waves in a reversed-field-pinch plasma. Yoshida, Z.; Hasegawa, A.; Wakatani, M. // Physics of Fluids B: Plasma Physics;Sep93, Vol. 5 Issue 9, p3261 

    Production of superthermal electrons through kinetic interactions with electromagnetic fluctuations is studied to account for observations of fast electrons and ion cyclotron waves in reversed field pinch plasmas. Low-frequency Alfvénic (torsional) modes can interact with electrons through...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.