TITLE

Time-dependent electron temperature diagnostics for high-power, aluminum z-pinch plasmas

AUTHOR(S)
Sanford, T. W. L.; Nash, T. J.; Mock, R. C.; Spielman, R. B.; Seamen, J.F.; McGurn, J. S.; Jobe, D.; Gilliland, T. L.; Vargas, M.; Whitney, K. G.; Thornhill, J. W.; Pulsifer, P. E.; Apruzese, J. P.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p852
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Discusses time-dependent electron temperature measurements for high-power aluminum z-pinch plasmas. Global implosion characteristics; Core-temperature diagnostic; Halo-temperature diagnostic and model.
ACCESSION #
630864

 

Related Articles

  • Development of a visible framing camera diagnostic for the study of current initiation in z-pinch plasmas Muron, D. J.; Hurst, M. J.; Derzon, M. S. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p656 

    Describes a visible framing camera built to observe early time visible emission from z-pinch plasmas at the Saturn pulsed-power driven accelerator at Sandia National Laboratories in Albuquerque, New Mexico. Camera system; Optical system; Variation in sensitivity and gain characteristics from...

  • Electron density and electron temperature measurement in a bi-Maxwellian electron distribution using a derivative method of Langmuir probes. Choi, Ikjin; Chung, ChinWook; Youn Moon, Se // Physics of Plasmas;Aug2013, Vol. 20 Issue 8, p083508 

    In plasma diagnostics with a single Langmuir probe, the electron temperature Te is usually obtained from the slope of the logarithm of the electron current or from the electron energy probability functions of current (I)-voltage (V) curve. Recently, Chen [F. F. Chen, Phys. Plasmas 8, 3029...

  • Development of KSTAR Thomson scattering system. Lee, J. H.; Oh, S. T.; Wi, H. M. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D528 

    To measure the electron temperature (Te) and electron density (ne) profiles in the Korean Superconducting Tokamak Advanced Research (KSTAR) device for the KSTAR third campaign (September 2010), we designed and installed a Thomson scattering system. The KSTAR Thomson scattering system is designed...

  • Comparative electron temperature measurements of Thomson scattering and electron cyclotron emission diagnostics in TCABR plasmas. Alonso, M. P.; Figueiredo, A. C. A.; Borges, F. O.; Elizondo, J. I.; Galvão, R. M. O.; Severo, J. H. F.; Usuriaga, O. C.; Berni, L. A.; Machida, M. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10D529 

    We present the first simultaneous measurements of the Thomson scattering and electron cyclotron emission radiometer diagnostics performed at TCABR tokamak with Alfvén wave heating. The Thomson scattering diagnostic is an upgraded version of the one previously installed at the ISTTOK tokamak,...

  • Design of a correlation electron cyclotron emission diagnostic for Alcator C-Mod. Sung, C.; White, A. E.; Irby, J. H.; Leccacorvi, R.; Vieira, R.; Oi, C. Y.; Peebles, W. A.; Nguyen, X. // Review of Scientific Instruments;Oct2012, Vol. 83 Issue 10, p10E311 

    A correlation electron cyclotron emission (CECE) diagnostic has been installed in Alcator C-Mod. In order to measure electron temperature fluctuations, this diagnostic uses a spectral decorrelation technique. Constraints obtained with nonlinear gyrokinetic simulations guided the design of the...

  • Anisotropic electron temperature measurements without knowing the spectral transmissivity for a JT-60SA Thomson scattering diagnostic. Tojo, H.; Hatae, T.; Yatsuka, E.; Itami, K. // Review of Scientific Instruments;Oct2012, Vol. 83 Issue 10, p10E346 

    This paper focuses on a method for measuring the electron temperature (Te) without knowing the transmissivity using Thomson scattering diagnostic with a double-pass scattering system. Application of this method for measuring the anisotropic Te, i.e., the Te in the directions parallel (Te||) and...

  • Asymmetric double Langmuir probe: Small signal application. Uckan, Taner // Review of Scientific Instruments;Dec1987, Vol. 58 Issue 12, p2260 

    We discuss the asymmetric double Langmuir probe (ADLP) and demonstrate the possibility of using it to measure plasma temperature Te and density n when it is operated in the region of small signal response. The area of one of the ADLP collectors is considerably larger than the other. This probe...

  • Puzzling particles challenge physicists.  // New Scientist;7/6/91, Vol. 131 Issue 1776, p23 

    Reports on researchers at the European Laboratory for Particle Physics in Geneva, Switzerland's study of the decay of Z particles, produced when electrons and positrons annihilate each other. Theoretical framework describing the relationship between matter and force particles; Tau particles...

  • Development of a spatially resolving x-ray crystal spectrometer for measurement of ion-temperature (Ti) and rotation-velocity (v) profiles in ITER. Hill, K. W.; Bitter, M.; Delgado-Aparicio, L.; Johnson, D.; Feder, R.; Beiersdorfer, P.; Dunn, J.; Morris, K.; Wang, E.; Reinke, M.; Podpaly, Y.; Rice, J. E.; Barnsley, R.; O'Mullane, M.; Lee, S. G. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E322 

    Imaging x-ray crystal spectrometer (XCS) arrays are being developed as a US-ITER activity for Doppler measurement of Ti and v profiles of impurities (W, Kr, and Fe) with ∼7 cm (a/30) and 10-100 ms resolution in ITER. The imaging XCS, modeled after a prototype instrument on Alcator C-Mod,...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics