TITLE

X-ray diagnostics of hohlraum plasma flow

AUTHOR(S)
Back, C. A.; Glenzer, S. H.; Landen, O. L.; MacGowan, B. J.; Shepard, T. D.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p831
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes the use of spectroscopy and x-ray imaging to investigate the macroscopic plasma flow in millimeter-sized laser-produced hohlraum plasmas. Position of dopants placed inside the hohlraum; Analysis of spatial movement of dopant plasmas for comparison to hydrodynamic calculations.
ACCESSION #
630856

 

Related Articles

  • Mechanism for the Disappearance of Spectral Lines in a Nonideal Plasma. Gryaznov, V. K.; Denisov, O. B.; Kulish, M. I.; Mintsev, V. B.; Orlov, N. Yu.; Fortov, V. E. // Plasma Physics Reports;Dec2001, Vol. 27 Issue 12, p1021 

    The mechanism for the �disappearance� of spectral lines in a nonideal plasma is explained theoretically. A comparison of the calculated results with the experimental data from measurements of the emission spectra from a shocked xenon plasma makes it possible to draw the conclusion that...

  • High-Resolution X-ray Emission Lα[sub 1] and Lβ[sub 2] Spectra of Hf, Ta, W, Re, and Os. Borovoı, N. A.; Kmetsinskaya, N. A.; Surzhko, V. F.; Shiyanovskiı, V. I. // Optics & Spectroscopy;Sep2002, Vol. 93 Issue 3, p345 

    The shape and relative intensities Sα = I(α[sub 1s])/I(α[sub 1]), S[sub β] = I(β[sub 2s])/I(β[sub 2]) of the short-wavelength X-ray Lα[sub 1] and Lβ[sub 2] satellites arising from the radiative decay of the states corresponding to L[sub 3]M[sub 4,5] configurations were...

  • Stopped-flow time-resolved extended x-ray-absorption fine structure technique for studying... Yohisda, Noboru; Nagamura, Toshihiko // Review of Scientific Instruments;Jan1995, Vol. 66 Issue 1, p52 

    Describes the construction of a stopped-flow apparatus suitable for x-ray absorption spectroscopy in dispersive mode. Integration of x-ray absorption signals over a time interval; Gate time depending on the concentration of the sample solution and the x-ray intensity from x-ray generator.

  • Plasma physics issues in laboratory x-ray lasers. Rosen, M. D. // Physics of Fluids B: Plasma Physics;Jun90, Vol. 2 Issue 6, p1461 

    Laboratories around the world are producing plasmas with atomic population inversions that are exhibiting gain at wavelengths approaching the carbon K edge near 44 Ã…, which is optimal for holography of wet biological samples. Often these demonstrations of gain are accompanied by anomalies...

  • A three-dimensional ray-tracing code dedicated to x-ray laser amplification simulation. Temporal, M.; Jacquemot, S.; Bonnet, L.; Decoster, A. // Physics of Plasmas;Apr2001, Vol. 8 Issue 4, p1363 

    A three-dimensional (3D) ray-tracing code has been developed to simulate the x-ray intensity produced in recent experiments where a silver target was driven by two laser beams. The code is used as a postprocessor of a detailed atomic physics code, which provides emissivities and opacities for...

  • On X-ray tube spectra, the dependence on the angular and electron energy of X-rays from the targets. A. Shaltout // European Physical Journal - Applied Physics;Mar2007, Vol. 37 Issue 3, p291 

    An algorithm was developed for the theoretical intensities of both X-ray continuum and characteristic K-radiation (K?1, K?2, K?, K?1, K?2, K?3, K?13, K?4and K?5) of different target materials (Cr, Cu, Rh, Mo, W, Ag and Au) at different electron incidence angles (0.01??90?), different take-off...

  • Effect of processing geometry on YBa2Cu3O7-x plasma emission during superconducting thin film growth by pulsed laser evaporation technique. Pramanick, S.; Narayan, J. // Journal of Applied Physics;1/1/1993, Vol. 73 Issue 1, p316 

    Provides information on a study that performed optical emission spectroscopy to understand the effects of the processing parameters and the processing geometry on YBa[sub2]Cu[sub3]O[sub7-x] plasma emission during superconducting thin film growth by pulsed laser evaporation. Details on the...

  • The X-ray microscopy facility at the ESRF: A status report. Susini, J.; Barrett, R.; Kaulich, B.; Oestreich, S.; Salome´, M. // AIP Conference Proceedings;2000, Vol. 507 Issue 1, p19 

    ID21 is a beamline dedicated to X-ray imaging and spectro-microscopy in the 0.2-7 kev energy range. Initiated four years ago, the beamline construction is almost completed and the beamline is now entering into the first operational phase. The beamline is installed on a low beta straight section...

  • Absolutely measured x-ray spectra from laser plasmas with targets of different elements. Eidmann, K.; Kishimoto, T. // Applied Physics Letters;8/18/1986, Vol. 49 Issue 7, p377 

    Soft x-ray spectra emitted by laser-produced plasmas in the wavelength range 10 Å<λ<250 Å were absolutely measured with a transmission grating and calibrated Kodak 101-01 film. Laser pulses with a length of 3 ns and a wavelength of 0.53 μm were focused at an intensity of 3×1013...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics