TITLE

Time-resolved two-dimensional monochromatic imaging of laser-imploded plasma

AUTHOR(S)
Miyanaga, N.; Aoki, Y.; Shiraga, H.; Shimada, K.; Fujimoto, K.; Heya, M.; Nakasuji, M.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p817
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Describes the development of a time-resolved, two-dimensional monochromatic imaging system for laser-imploded plasma. Ignition process in inertial confinement fusion; Principle of the monochromatic multi-imaging x-ray streak camera; Streaked pictures; Spatial and temporal resolutions.
ACCESSION #
630852

 

Related Articles

  • Plasma diagnosis related to ion sources (invited). Girard, A. // Review of Scientific Instruments;Apr92, Vol. 63 Issue 4, p2676 

    The different kinds of ion sources have been most commonly classified according to the extracted beam parameters: ion charge state, energy and current, and beam quality. We adopt here a somewhat different approach: ion sources are usually plasma sources where each component (ionic as well as...

  • First results of collective scattering on JET (invited) Hoekzema, D. A.; Bindslev, H.; Egedal, J.; Fessey, J. A.; Gatcombe, C. P.; Hammond, N. P.; Hughes, T. P.; Machuzak, J. S.; Oosterbeek, J. W.; Roberts, P. J.; Stevens, A. L.; Stott, P. E. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p275 

    Reports on the first results of Thomson scattering-based fast ion and alpha-particle diagnostics at JET Joint Undertaking in Great Britain. Description of the diagnostic system; Initial operation; Ongoing developments for alpha particle measurements.

  • Fast imaging of tokamak plasmas with integrated photodiode arrays. Castracane, J.; Demers, Y. // Applied Physics Letters;3/17/1986, Vol. 48 Issue 11, p692 

    Images with high temporal and spatial resolution of the resurrector tokamak plasma were obtained. The plasma cross section was focused onto a commercially available 128 pixel photodiode array (active area: 2.5×3.2 mm2). Specially designed data acquisition electronics allowed rapid readout...

  • Modeling of three-dimensional camera imaging in a tokamak torus Edmonds, P. H.; Medley, S.S. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p918 

    Describes a procedure for precision modeling of the views for imaging diagnostics monitoring tokamak internal components, particularly high heat flux divertor components. Measurement of image resolution and viewing incidence angle; Analytic calculation of resolution.

  • Spectroscopic imaging system for quantitative analysis of the divertor plasma of the Tokamak de... Meo, F.; Stansfield, B.L.; Chartre, M.; de Villers, P.; Marchand, R.; Ratel, G. // Review of Scientific Instruments;Sep97, Vol. 68 Issue 9, p3426 

    Discusses the development of a toroidally viewing spectroscopic imaging system for the Tokamak de Varennes. Measurements of the poloidal distribution of the absolute radiated power of deuterium and impurity species in the upper divertor region; Measurements of the divertor strike point and the...

  • Plasma diagnostics in an astrophysical setting: Early results from the CCD-based, imaging x-ray... Ricker, G.R. // Review of Scientific Instruments;Jan1995, Vol. 66 Issue 1, p585 

    Discusses the applications of the Solid-State Imaging Spectrometer (SIS) for the Japan-US Advanced Satellite for Cosmology and Astrophysics (ASCA) project. Incorporation of silicon charge-coupled device array with low noise.

  • International Fusion Materials Irradiation Facility injector acceptance tests at CEA/Saclay: 140 mA/100 keV deuteron beam characterization. Gobin, R.; Bogard, D.; Cara, P.; Chauvin, N.; Chel, S.; Delferrière, O.; Harrault, F.; Mattei, P.; Mosnier, A.; Senée, F.; Shidara, H.; Okumura, Y. // Review of Scientific Instruments;2014, Vol. 85 Issue 2, p1 

    In the framework of the ITER broader approach, the International Fusion Materials Irradiation Facility (IFMIF) deuteron accelerator (2 x 125 mA at 40 MeV) is an irradiation tool dedicated to high neutron flux production for future nuclear plant material studies. During the validation phase, the...

  • Electron cyclon emission imaging of electron temperature profiles and fluctuations (invited)(abstract). Cima, G.; Deng, B.; Domier, C. W.; Geck, W. R.; Hsia, R. P.; Liang, C.; Jiang, F.; Luhmann, Jr., N. C.; Brower, D.; Watts, C. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p408 

    Presents an abstract of a paper that focuses on electron cyclotron emission (ECE) imaging of electron temperature profiles and fluctuations. Reasons why ECE is a powerful diagnostic in a high performance/high magnetic field, magnetic confinement experiment; Description of the device.

  • First results from the phase contrast imaging system on TEXT-U Chatterjee, R.; Hallock, G. A. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p676 

    Describes the successful operation of a phase contrast imaging (PCI) diagnostic with a vertical beam covering the central third of the plasma to study density fluctuations in the TEXT-U tokamak. Optical design and layout; Tests and calibration of PCI.

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics