TITLE

Soft x-ray and bolometric tomography in RFX (abstract)

AUTHOR(S)
Martin, P.; Murari, A.; Buffa, A.; Marrelli, L.; Baker, W.; Gadani, G.; Hemming, O.; Manduchi, G.; Parini, A.; Taliercio, C.; Hoffmann, A.; Stasek, G.; Wirth, R.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p761
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Presents the design and the first results of an eight-camera soft x-ray and bolometric tomography which has been installed in RFX, a high current reverse field pinch experiment operating in Padova, Italy. Main features of the diagnostic; Components.
ACCESSION #
630836

 

Related Articles

  • Soft x-ray and bolometric tomography in RFX. Martin, P.; Murari, A.; Buffa, A.; Marrelli, L.; Baker, W.; Gadani, G.; Hemming, O.; Manduchi, G.; Parini, A.; Taliercio, C.; Hoffmann, A.; Stasek, G.; Wirth, R. // Review of Scientific Instruments;Feb1997, Vol. 68 Issue 2, p1256 

    Details the design of an eight-camera soft x-ray (SXR) and bolometric tomography which has been installed in RFX, a high-current reverse field pinch experiment operating in Padova, Italy. Reconstruction of SXR and total radiation emissivity structures; Inclusion of eight fully remotely...

  • Signal processing and general purpose data acquisition system for on-line tomographic measurements Murari, A.; Martin, P.; Hemming, O.; Manduchi, G.; Marrelli, L.; Taliercio, C.; Hoffmann, A. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p951 

    Describes the development of analog signal conditioning electronics and data acquisition systems for the soft x-ray and bolometric tomography diagnostic in the reverse field pinch experiment. Signal processing analog electronics; Main tasks that the data acquisition system deals with; Software...

  • Tangential soft-x ray imaging for three-dimensional structural studies in a reversed field pinch. Onchi, T.; Ikezoe, R.; Oki, K.; Sanpei, A.; Himura, H.; Masamune, S. // Review of Scientific Instruments;Jul2010, Vol. 81 Issue 7, p073502 

    Tangential soft-x ray (SXR) imaging diagnostic has been developed and three-dimensional (3D) structure of the internal magnetic surface has been deduced by comparing the experimental and calculated two-dimensional SXR images in a reversed field pinch. The SXR imaging system, consisting of a MCP,...

  • A new double-foil soft x-ray array to measure Te on the MST reversed field pinch. McGarry, M. B.; Franz, P.; Den Hartog, D. J.; Goetz, J. A. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E516 

    A soft x-ray (SXR) diagnostic to measure electron temperature on the Madison Symmetric Torus using two complementary methods is presented. Both methods are based on the double-foil technique, which calculates electron temperature via the ratio of SXR bremsstrahlung emission from the plasma in...

  • An optimized multifoil soft x-ray spectrometer for the determination of the electron temperature... Murari, A.; Franz, P.; Zabeo, L.; Bartimoro, R.; Carraro, L.; Gadani, G.; Marrelli, L.; Martin, P.; Pasqualotto, R.; Valisa, M. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p581 

    Describes the design and operation of an optimized, multifoil soft x-ray spectrometer for the determination of the electron temperature with high time resolution in reversed field pinch. Components of the system; Measured values of the electron temperature and its correlation with main plasma...

  • Compact soft x-ray multichord camera: Design and initial operation. Franz, P.; Gadani, G.; Pasqualotto, R.; Marrelli, L.; Martin, P.; Spizzo, G.; Brunsell, P.; Chapman, B. E.; Paganucci, F.; Rossetti, P.; Xiao, C. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p2152 

    A compact and low cost diagnostic for spatially resolved measurements of soft x-ray or total radiation emission has been designed and realized to be flexibly applied to different plasma physics experiments. Its reduced size (outer diameter=35 mm) makes it suited to a variety of devices. The line...

  • Soft-x-ray emission, plasma equilibrium, and fluctuation studies on Madison Symmetric Torus. Xiao, C.; Franz, P.; Chapman, B. E.; Craig, D.; Ding, W. X.; Gadani, G.; Marrelli, L.; Martin, P.; Pasqualotto, R.; Spizzo, G.; Sarff, J. S.; Terry, S. D. // Review of Scientific Instruments;Mar2003, Vol. 74 Issue 3, p2157 

    A miniature multichord soft-x-ray detection system has been installed on the Madison Symmetric Torus (MST) reversed-field pinch to study the plasma equilibrium and fluctuation properties of standard- and improved-confinement discharges. Because of the relatively flat MST density and temperature...

  • Measurement of global instability of compact torus by three-dimensional tomography. Kawamori, E.; Sumikawa, T.; Ono, Y.; Balandin, A. // Review of Scientific Instruments;Sep2006, Vol. 77 Issue 9, p093503 

    The new three-dimensional tomography reconstruction system based on the novel scheme suggested by Balandin et al. [Eur. Phys. J. D 14, 97 (2001)] was developed for a powerful monitor of compact torus (CT) plasma using 16 two-dimensional (2D) projections of visible light. This system can obtain...

  • Soft x-ray tomography diagnostic for the Alcator C tokamak. Camacho, J. F.; Granetz, R. S. // Review of Scientific Instruments;Mar86, Vol. 57 Issue 3, p417 

    A soft x-ray tomography diagnostic has been built and operated on the Alcator C tokamak with the use of an 80-channel array of detectors. The detector system consists of miniature PIN photodiodes which are located around the periphery of the plasma at one toroidal location (top and bottom ports)...

Share