TITLE

Avalanche photodiodes operating parameter optimization for the Frascati Tokamak Upgrade Thomson scattering system (abstract)

AUTHOR(S)
Orsitto, F.; Brusadin, A.; Giovannozzi, E.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p699
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Reports on measured figures of the avalanche photodiodes detectors (APD) used on the FTU Thomson scattering system. Motivations for the investigation of APD figures; Derivation of a method of optimization of the detection system sensitivity.
ACCESSION #
630818

 

Related Articles

  • Silicon avalanche photodiode detector circuit for Nd:YAG laser scattering. Hsieh, C. L.; Haskovec, J.; Carlstrom, T. N.; DeBoo, J. C.; Greenfield, C. M.; Snider, R. T.; Trost, P. // Review of Scientific Instruments;Oct90, Vol. 61 Issue 10, p2855 

    A silicon avalanche photodiode with an internal gain of about 50 to 100 is used in a temperature-controlled environment to measure the Nd:YAG laser Thomson scattered spectrum in the wavelength range from 700 to 1150 nm. A charge-sensitive preamplifier has been developed for minimizing the noise...

  • APD detector electronics for the NSTX Thomson scattering system. Johnson, D. W.; LeBlanc, B. P.; Long, D. L.; Renda, G. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p1129 

    An electronics system has been installed and tested for the readout of avalanche photodiode (APD) detectors for the National Spherical Torus Experiment (NSTX) Thomson scattering system. Similar to previous designs, it features preamps with a fast and a slow output. The fast output uses pulse...

  • Electronics for microchannel photomultipliers in the LIDAR Thomson scattering diagnostic on JET. Bundgaard, J.; Hansen, K. B.; Weisberg, K.-V. // Review of Scientific Instruments;Oct89, Vol. 60 Issue 10, p3265 

    The electronics for the microchannel plate photomultiplier tubes used in the LIDAR (Light Detection and Ranging) Thomson scattering diagnostic on the JET tokamak are described. It is shown how the microchannel plate photomultiplier tubes are gated with a very small coupling between gate signal...

  • A compact and high repetitive photodiode array detector for the JT-60U Thomson scattering... Yoshida, H.; Naito, O.; Sakuma, T.; Kitamura, S.; Hatae, T.; Nagashima, A. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p747 

    Describes the development of a compact and two-dimensional detector for the JT-60U Thomson scattering system that consists mainly of a proximity focused image intensifier, an arrayed silicon photodiode and a data processing unit. Design of the and components of the detector system; Detector...

  • Study of Fast, Near-Infrared Photodetectors for the ITER Core LIDAR Thomson Scattering. Giudicotti, L.; Pasqualotto, R.; Alfier, A.; Beurskens, M.; Kempenaars, M.; Walsh, M. J. // AIP Conference Proceedings;3/12/2008, Vol. 988 Issue 1, p144 

    A key component for the ITER core LIDAR Thomson Scattering (TS) diagnostic would be a detector with good sensitivity in the 850-1060 nm near infrared (NIR) spectral region. Covering this spectral region becomes necessary if a Nd:YAG laser system operating at λ = 1.06 μm is used as the...

  • A combined Thomson–Rayleigh scattering diagnostic using an intensified photodiode array. van de Sanden, M. C. M.; Janssen, G. M.; de Regt, J. M.; Schram, D. C.; van der Mullen, J. A. M.; van der Sijde, B. // Review of Scientific Instruments;Jun92, Vol. 63 Issue 6, p3369 

    A combined Thomson–Rayleigh scattering device is discussed. It consists of a Nd:YAG laser as a light source in combination with a multichannel detection technique consisting of a gated light amplifier in combination with an optical multichannel analyzer. Special attention is focused on...

  • Calibration of a Thomson scattering diagnostic for fluctuation measurements. Stephens, H. D.; Borchardt, M. T.; Den Hartog, D. J.; Falkowski, A. F.; Holly, D. J.; O’Connell, R.; Reusch, J. A. // Review of Scientific Instruments;Oct2008, Vol. 79 Issue 10, p10E734 

    Detailed calibrations of the Madison Symmetric Torus polychromator Thomson scattering system have been made suitable for electron temperature fluctuation measurements. All calibrations have taken place focusing on accuracy, ease of use and repeatability, and in situ measurements wherever...

  • Comparison of multialkali and GaAs photocathode detectors for Joint European Torus edge light detection and ranging Thomson scattering profiles. Kempenaars, M.; Nielsen, P.; Pasqualotto, R.; Gowers, C.; Beurskens, M. // Review of Scientific Instruments;Oct2004 Part I & II, Vol. 75 Issue 10, p3894 

    The Joint European Torus (JET) tokamak has two light detection and ranging (LIDAR) Thomson scattering systems, one for the core and one dedicated to the edge Te and ne profiles. The LIDAR scheme is unique to JET and is envisaged for use on ITER. The system’s spatial resolution is defined...

  • Thomson scattering calibration with ultrabright supercontinuum light source. Pasqualotto, R.; Alfier, A. // Review of Scientific Instruments;Oct2006, Vol. 77 Issue 10, p10E502 

    The recently developed supercontinuum light source (SLS) finds a useful application in the calibration of a Thomson scattering (TS) diagnostic. When filter polychromators are used, the relative responsivity of the spectral channels is generally measured with a cw halogen light source from the dc...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics