TITLE

Interpretation of neutron time-of-flight signals from current-mode detectors

AUTHOR(S)
Murphy, T. J.; Chrien, R. E.; Klare, K. A.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p610
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Discusses neutron time-of-flight signals from current-mode neutron detectors, which mare used to measure the neutron yield, ion temperature, and neutron emission time of inertial confinement fusion (ICF) targets on Nova, Omega, and other large ICF facilities. Response function of current-mode neutron detectors; Determination of response parameters; Temperature measurements.
ACCESSION #
630792

 

Related Articles

  • Development of portable long counter with two different moderator materials. Tanimura, Y.; Tsutsumi, M.; Yoshizawa, M. // Radiation Protection Dosimetry;Oct2014, Vol. 161 Issue 1-4, p144 

    A portable, light-weight long counter (LC) with small dimensions was developed. This LC consists of a 3He thermal neutron counter, a cylindrical moderator and outer shields. It was designed to have an almost flat response in a neutron energy range of 0.4 eV to 5 MeV. The portable LC has a radius...

  • Deuterated Liquid Scintillators: A New Tool for Neutron Measurements. Ojaruega, M.; Becchetti, F. D.; Villano, A. N.; Torres-Isea, R.; Roberts, A.; Kolata, J. J.; Lawrence, C. C.; Pozzi, S. A.; Flaska, M.; Clarke, S. D. // AIP Conference Proceedings;12/13/2011, Vol. 1412 Issue 1, p249 

    The response of large (4×6) deuterated liquid scintillators (up to 10 cm diameter by 15 cm) to neutrons in the energy range from 0.5 MeV to 20 MeV has been studied using several nuclear reactions, including d(d,n), and 12C(d,n)13N, at the University of Notre Dame FN tandem accelerator. The...

  • Search for 2νββ Decay of 130Te to the First Excited State of 130Xe with an Ultra-Low-Background Germanium Crystal Array. Mizouni, L. K.; Aalseth, C. E.; Avignone, F. T.; Erikson, L. E.; Hossbach, T. W.; Keillor, M. E.; Orrell, J. L. // AIP Conference Proceedings;12/13/2011, Vol. 1412 Issue 1, p232 

    The goal of searching for zero-neutrino double-beta (0νββ) decay is to probe an absolute neutrino mass scale suggested by the mass-splitting parameters observed by neutrino oscillation experiments. Furthermore, observation of 0νββ decay is an explicit instance of Lepton-number...

  • Simulation of Charge Collection in Diamond Detectors Irradiated with Deuteron-Triton Neutron Sources. Milocco, Alberto; Trkov, Andrej; Pillon, Mario // AIP Conference Proceedings;12/13/2011, Vol. 1412 Issue 1, p224 

    Diamond-based neutron spectrometers exhibit outstanding properties such as radiation hardness, low sensitivity to gamma rays, fast response and high-energy resolution. They represent a very promising application of diamonds for plasma diagnostics in fusion devices. The measured pulse height...

  • Characterization of Monoenergetic Low Energy Neutron Fields with the μTPC Detector. Golabek, C.; Billard, J.; Grignon, C.; Bosson, G.; Bourrion, O.; Guillaudin, O.; Lebreton, L.; Mayet, F.; Petit, M.; Richer, J.-P.; Santos, D. // AIP Conference Proceedings;12/13/2011, Vol. 1412 Issue 1, p192 

    The AMANDE facility produces monoenergetic neutron fields from 2 keV to 20 MeV for metrological purposes. To be considered as a reference facility, fluence and energy distributions of neutron fields have to be determined by primary measurement standards. For this purpose, a micro Time Projection...

  • Performance comparison of 2.8 MeV and 241Am-Be neutrons based moisture measurement setups. Abdelmonem, M. S.; Naqvi, A. A.; Al-Ghamdi, Hanan; Al-Misned, Ghada // Journal of Radioanalytical & Nuclear Chemistry;Oct2007, Vol. 274 Issue 1, p1 

    Performance of a 241Am-Be neutron source-based and 2.8 MeV neutrons-based moisture measurement setups have been compared using Monte Carlo simulation. In the setup fast neutrons transmitted through the sample were detected by a fast neutron detector, which was placed behind a massive long double...

  • Development of Reader System for Superheated Emulsion Neutron Detector and its Performance Evaluation. Meena, J. P.; Parihar, A.; Vaijapurkar, S. G.; Mohan, Anand // International Journal on Recent Trends in Engineering & Technolo;Nov2010, Vol. 4 Issue 4, p155 

    The paper presents development of microcontroller based automatic reader system for neutron measurement using indigenously developed superheated emulsion detector and its performance evaluation. The system is designed for real time counting of bubbles formed in superheated emulsion detector. A...

  • β-delayed neutron emission measurements around the third r-process abundance peak. Caballero-Folch, R.; Domingo-Pardo, C.; Taín, J. L.; Cortés, G.; Agramunt, J.; Algora, A.; Ameil, F.; Ayyad, Y.; Benlliure, J.; Bowry, M.; Calviño, F.; Cano-Ott, D.; Davinson, T.; Dillmann, I.; Estrade, A.; Evdokimov, A.; Faestermann, T.; Farinon, F.; Galaviz, D.; García-Rios, A. // AIP Conference Proceedings;Jun2013, Vol. 1541 Issue 1, p137 

    This contribution summarizes an experiment performed at GSI (Germany) in the neutron-rich region beyond N=126. The aim of this measurement is to provide the nuclear physics input of relevance for r-process model calculations, aiming at a better understanding of the third r-process abundance...

  • A Monte Carlo study of the effect of coded-aperture material and thickness on neutron imaging. Hayes, S. C.; Gamage, K. A. A. // Radiation Protection Dosimetry;Oct2014, Vol. 161 Issue 1-4, p265 

    In this paper, a coded-aperture design for a scintillator-based neutron imaging system has been simulated using a series of Monte Carlo simulations. Using Monte Carlo simulations, work to optimise a system making use of the EJ-426 neutron scintillator detector has been conducted. This type of...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library