TITLE

Measurements of neutron spectra from Nova targets

AUTHOR(S)
Chrien, R. E.; Klare, K. A.; Murphy, T. J.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p607
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Discusses measurements of neutron spectra from targets on the Nova laser. Direct-drive implosions; Indirect-drive implosions; Gas-filled hohlraums.
ACCESSION #
630791

 

Related Articles

  • Target diagnostic control system implementation for the National Ignition Facility (invited). Shelton, R. T.; Kamperschroer, J. H.; Lagin, L. J.; Nelson, J. R.; O'Brien, D. W. // Review of Scientific Instruments;Oct2010, Vol. 81 Issue 10, p10E101 

    The extreme physics of targets shocked by NIF's 192-beam laser is observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A diagnostic control system (DCS) framework for...

  • Nuclear diagnostics for petawatt experiments (invited). Stoyer, M. A.; Sangster, T. C.; Henry, E. A.; Cable, M. D.; Cowan, T. E.; Hatchett, S. P.; Key, M.H.; Moran, M. J.; Pennington, D. M.; Perry, M. D.; Phillips, T. W.; Singh, M. S.; Snavely, R. A.; Tabak, M.; Wilks, S. C. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p767 

    With the operation of successively more intense and powerful lasers, such as the NOVA petawatt laser with I∼3×10[sup 20] W/cm[sup 2], several novel (to laser physics) nuclear diagnostics were used to determine the nature of the laser/matter interaction at the target surface. A broad...

  • Precision metrology of NSTX surfaces using coherent laser radar ranging. Kugel, H. W.; Loesser, D.; Roquemore, A. L.; Menon, M. M.; Barry, R. E. // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p533 

    A frequency modulated Coherent Laser Radar ranging diagnostic is being used on the National Spherical Torus Experiment (NSTX) for precision metrology. The distance (range) between the 1.5 μm laser source and the target is measured by the shift in frequency of the linearly modulated beam...

  • Construction of a near-field spectrum analysis system using bent tapered fiber probes. Chen, Sy-Hann; Chen, Yung-Fu // Review of Scientific Instruments;Jan2001, Vol. 72 Issue 1, p268 

    We take advantage of a combination of laser heating and pulling and electric arc bending to fabricate bent tapered fiber probes. The bent angles can be varied from 30° to 70° and tip diameters fall within a few tens of nanometers. These bent fiber probes can easily be adapted into any...

  • Extremely compact capillary discharge-based soft x-ray laser development and application to dense plasma diagnostics. Rocca, J. J.; Luther, B.; Marconi, M. C.; Whiteaker, T.; Braley, D. A.; Filevich, J.; Hammarsten, E. C.; Rahman, A.; Szapiro, B. T.; Wang, Y.; Jankowska, E.; Grisham, M.; Shlyaptsev, V. N.; Moon, S. // AIP Conference Proceedings;2002, Vol. 641 Issue 1, p125 

    We give an overview of recent capillary discharge-driven soft x-ray laser development experiments and applications ar Colorado State University. We report the demonstration of the first desktop size soft x-ray laser, a capillary discharge Ne-like Ar soft x-ray laser that was measured to emit...

  • Simulation of the Rayleigh–Taylor instability in colliding, ablatively driven laser foils. Dahlburg, J. P.; Gardner, J. H.; Emery, M. H. // Physics of Fluids B: Plasma Physics;Dec91, Vol. 3 Issue 12, p3485 

    This paper reports results from a series of numerical simulations of a pair of independently accelerated rectilinear foils in the presence of the ablative Rayleigh–Taylor (RT) instability on the laser-side surfaces. The foil thickness and laser intensity are chosen to be in the range...

  • Infrared thermography of the DIII-D divertor targets. Hill, D. N.; Ellis, R.; Ferguson, W.; Perkins, D. E.; Petrie, T.; Baxi, C. // Review of Scientific Instruments;Aug1988, Vol. 59 Issue 8, p1878 

    The power flow to the DIII-D divertor targets is routinely measured using infrared (IR) thermography. An IR television camera sensitive to radiation in the 8-12-µm range views the divertor region using a set of germanium optics. Digital signal processing is used to extract the desired surface...

  • Recent diagnostic developments at Nova (invited). Kilkenny, J. D. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p4688 

    The Nova laser at Lawrence Livermore National Laboratory has about 60 diagnostics in use on its two target chambers. The broad rationale for the diagnostics is explained. Recent developments in diagnostic techniques on Nova for implosions, soft x-ray studies, and x-ray laser applications are...

  • Shock timing technique for the National Ignition Facility. Munro, David H.; Celliers, Peter M.; Collins, Gilbert W.; Gold, David M.; Da Silva, Luiz B.; Haan, Steven W.; Cauble, Robert C.; Hammel, Bruce A.; Hsing, Warren W. // Physics of Plasmas;May2001, Vol. 8 Issue 5, p2245 

    Among the final shots at the Nova laser [Campbell et al., Rev. Sci. Instrum. 57, 2101 (1986)] was a series testing the VISAR (velocity interferometry system for any reflector) technique that will be the primary diagnostic for timing the shocks in a NIF (National Ignition Facility) ignition...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics