TITLE

Measurements of the neutron source strength at DIlI-D

AUTHOR(S)
Heidbrink, W. W.; Taylor, P. L.; Phillips, J. A.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p536
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Documents the calibration procedure for neutron counters and scintillators used to measure the neutron emission produced by the DIII-D tokamak. Detectors and calibration; Detector comparisons; Comparison with other diagnostics.
ACCESSION #
630772

 

Related Articles

  • Calibration issues of the Tokamak Fusion Test Reactor multichannel neutron collimator. von Goeler, S.; Johnson, L. C.; Bitter, M.; Efthimion, P. C.; Roquemore, A. L. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p548 

    Evaluates the calibration procedures for the detectors in the neutron collimator of the Tokamak Fusion Test Reactor. Deuterium-tritium jog shot calibration of the Bay A detectors; Detector nonlinearity; Deuterium-deuterium (DD) jog shot for the scattered DD neutron background.

  • Development of a geometry-compensated neutron time-of-flight detector for ICF applications with approximately 200 ps time response. Murphy, T. J.; Lerche, R. A. // Review of Scientific Instruments;Oct92, Vol. 63 Issue 10, p4883 

    Current-mode neutron time-of-flight detectors are used on Nova for neutron yield, ion temperature, and neutron emission time measurements. Currently used detectors are limited by the time response of the microchannel plate photomultiplier tubes used with the scintillators, scintillator decay...

  • Neutron spectrometry in neutron and charged-particle mixed fields with phoswich neutron detector. Takada, Masashi; Taniguchi, Shingo; Nakamura, Takashi; Fujitaka, Kazunobu // AIP Conference Proceedings;2001, Vol. 576 Issue 1, p579 

    We have developed the phoswich neutron detector consisting of the NE115 and NE213 scintillators which can distinguish neutron and photon events from charged-particle events. The performance of distinguishing photon and neutron events from charged-particle events was investigated in two neutron...

  • First measurement of neutron emission profile on JT-60U using Stilbene neutron detector with neutron-gamma discrimination. Ishikawa, M.; Nishitani, T.; Morioka, A.; Takechi, M.; Shinohara, K.; Shimada, M.; Miura, Y.; Nagami, M.; Kaschuck, Yu. A. // Review of Scientific Instruments;Dec2002, Vol. 73 Issue 12, p4237 

    This article describes a diagnostic for measuring neutron emission profile in JT-60U. The Stilbene neutron detector, developed by TRINITI laboratory in Russia, has been installed on the JT-60U Tokamak to measure the neutron emission profile for the first time. The Stilbene neutron detector is a...

  • Conceptual design for a scintillating-fiber neutron detector for fusion reactor plasma diagnostics. Sailor, W.C.; Barnes, Cris W.; Chrien, R.E.; Wurden, G.A. // Review of Scientific Instruments;Jan1995, Vol. 66 Issue 1, p898 

    Describes a conceptual design for pointing neutron detector capable of delivering count rates of events from triton burnup at a deuterium-burning tokamak. Collimated bundles of scintillating bundles consisting the detector; Separation by metal and polyethylene; Bundles set into a larger collimator.

  • Measurements and simulations of the neutron production at W7-AS. Wolle, B.; Weller, A.; Schill, S.; Gadelmeier, F.; Baloui, T.; Beikert, G. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p1197 

    Presents the results of neutron counter calibration campaigns at the W7-AS stellarator. Neutron counters comprising the neutron diagnostic system of the stellarator; Calibration of the counters in situ using a [sup 238]Pu/B neutron source placed at discrete points inside the vacuum vessel;...

  • Calibration of the neutron detectors for the cluster fusion experiment on the Texas Petawatt Laser. Bang, W.; Quevedo, H. J.; Dyer, G.; Rougk, J.; Kim, I.; McCormick, M.; Bernstein, A. C.; Ditmire, T. // Review of Scientific Instruments;Jun2012, Vol. 83 Issue 6, p063504 

    Three types of neutron detectors (plastic scintillation detectors, indium activation detectors, and CR-39 track detectors) were calibrated for the measurement of 2.45 MeV DD fusion neutron yields from the deuterium cluster fusion experiment on the Texas Petawatt Laser. A Cf-252 neutron source...

  • Long-term performance of neutron detectors during deuterium-tritium operation in the Tokamak... Jassby, D.L.; Barnes, Cris W.; Bitter, M.; Johnson, L.C.; Lemunyan, G.; Roquemore, A.L.; von Goeler, S. // Review of Scientific Instruments;Jan1999, Vol. 70 Issue 1, p1111 

    Examines the long-term performance of neutron detectors during deuterium-tritium operation in the Tokamak Fusion Test Reactor. Overview on the detector; Comparison of neutron yields; Statistics of yield ratios; Physical reliability.

  • Scintillating-fiber 14 MeV neutron detector on TFTR during DT operation. Wurden, G.A.; Chrien, R.E.; Barnes, Cris W.; Sailor, W.C.; Roquemore, A.L.; Lavelle, M.J.; O'Gara, P.M.; Jordan, R.J. // Review of Scientific Instruments;Jan1995, Vol. 66 Issue 1, p901 

    Tests a compact neutron detector using an array of scintillating fibers on the Tokamak Fusion Test Reactor (TFTR) tokamak under conditions of a high gamma background. Use of a fiber-matrix geometry; Magnetic field-insensitive phototube with an active base; Pulse-height discrimination to reject...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library

Other Topics