TITLE

Neutron diagnostics in compact helical system

AUTHOR(S)
Isobe, M.; Sasao, M.; Osakabe, M.; Fujita, J.; Okamura, S.; Kumazawa, R.; Matsuoka, K.; Takahashi, C.
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p532
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Discusses the application of an efficient neutron diagnostic system to deuterium experiments on compact helical systems. Counter operation in stray magnetic field; Ion temperature measurement; Confinement study of neutral beam-injected fast ion.
ACCESSION #
630771

 

Related Articles

  • Neutron activation measurements over an extremely wide dynamic range (invited) (abstract) Barnes, Cris W // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p520 

    Presents an abstract of a paper discussing absolutely calibrated neutron yield measurements over an extremely wide dynamic range using dosimetric reactions with thin elemental foils. International Thermonuclear Experimental Reactor burn durations; Thin foil techniques' lack of the sensitivity...

  • Conceptual design for a scintillating-fiber neutron detector for fusion reactor plasma diagnostics. Sailor, W.C.; Barnes, Cris W.; Chrien, R.E.; Wurden, G.A. // Review of Scientific Instruments;Jan1995, Vol. 66 Issue 1, p898 

    Describes a conceptual design for pointing neutron detector capable of delivering count rates of events from triton burnup at a deuterium-burning tokamak. Collimated bundles of scintillating bundles consisting the detector; Separation by metal and polyethylene; Bundles set into a larger collimator.

  • Measuring the absolute deuterium-tritium neutron yield using the magnetic recoil spectrometer at OMEGA and the NIF. Casey, D. T.; Frenje, J. A.; Gatu Johnson, M.; Séguin, F. H.; Li, C. K.; Petrasso, R. D.; Glebov, V. Yu.; Katz, J.; Knauer, J. P.; Meyerhofer, D. D.; Sangster, T. C.; Bionta, R. M.; Bleuel, D. L.; Döppner, T.; Glenzer, S.; Hartouni, E.; Hatchett, S. P.; Le Pape, S.; Ma, T.; MacKinnon, A. // Review of Scientific Instruments;Oct2012, Vol. 83 Issue 10, p10D912 

    A magnetic recoil spectrometer (MRS) has been installed and extensively used on OMEGA and the National Ignition Facility (NIF) for measurements of the absolute neutron spectrum from inertial confinement fusion implosions. From the neutron spectrum measured with the MRS, many critical implosion...

  • Radiometric Complex with Gamma Spectrometers for Measuring the Characteristics of Neutron Fields at Nuclear-Physics Installations. Sevast'yanov, V.; Kovalenko, O.; Zelenov, D.; Orlov, A. // Measurement Techniques;Jun2013, Vol. 56 Issue 3, p314 

    A method for measuring the induced activity in neutron activation detectors using gamma spectrometers with scintillator and semiconductor detectors is introduced. The sensitivity of the gamma spectrometers is measured as a function of γ-ray energy over a range of 0.06-3 MeV.

  • Time-resolved 14-MeV neutron detector for triton confinement studies. Smith, J. R.; Fisher, R. K.; Leffler, J. S.; Newman, D. E. // Review of Scientific Instruments;Aug1986, Vol. 57 Issue 8, p1780 

    Previous measurements of triton burnup in deuterium tokamak plasmas show an anomalously small burnup for low-q discharges with significant magnetohydrodynamic activity. This may have important implications for alpha particle burnup in a fusion reactor. By developing a detector capable of...

  • Distinction between DD and DT neutrons in the TFTR neutron collimator (abstract) Bitter, M.; Johnson, L. C.; Ku, Long-Poe; Roquemore, A. L.; von Goeler, S. // Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p552 

    Presents an abstract of a paper discussing the distinction between contributions from deuterium-deuterium and deuterium-tritium neutrons in the analysis of data from the Tokamak Fusion Test Reactor (TFTR) neutron collimator. Nature of TFTR discharges; Description of a multilayered plastic...

  • Use of daily detector verification data for isotopical half-life determination. Gonçalves, Vitor C.; Zahn, Guilherme S.; Genezini, Frederico A.; Ticianelli, Regina B.; Saiki, Mitiko // AIP Conference Proceedings;May2013, Vol. 1529 Issue 1, p113 

    In this work, the possibility of using data fromthe daily detector verification routines performed at the Neutron Activation Laboratory of IPEN to determine precise values for the half-lives of 57Co and 60Co was evaluated. For this purpose data from 4 of the laboratory's detectors, some spanning...

  • Experimental Study of the Deformation of Instantaneous Neutron Spectra from the Fission of 235U Nuclei in Fast-Reactor Core Materials. Sevast’yanov, V.; Koshelev, A.; Maslov, G. // Instruments & Experimental Techniques;Jul/Aug2005, Vol. 48 Issue 4, p433 

    The results from studies of the deformation of the instantaneous neutron spectra resulting from the fission of 235U nuclei in the material of structural elements of a fast reactor core are presented. The neutron spectra at and near the center of the reactor core were measured using neutron...

  • High aspect ratio composite structures with 48.5% thermal neutron detection efficiency. Shao, Q.; Voss, L. F.; Conway, A. M.; Nikolic, R. J.; Dar, M. A.; Cheung, C. L. // Applied Physics Letters;2/11/2013, Vol. 102 Issue 6, p063505 

    The pillar structured thermal neutron detector is based on the combination of high aspect ratio silicon p-i-n pillars surrounded by the neutron converter material 10B. By etching high aspect ratio pillar structures into silicon, the result is a device that efficiently absorbs the thermal neutron...

Share

Read the Article

Courtesy of THE LIBRARY OF VIRGINIA

Sorry, but this item is not currently available from your library.

Try another library?
Sign out of this library