TITLE

Millimeter-wave two-dimensional imaging array for the GAMMA 10 tandem mirror

AUTHOR(S)
Oyama, N.; Mase, A; Tokuzawa, T; Imamura, K.; Itakura, A; Tamano, T; Harada, Y; Mizuno, K
PUB. DATE
January 1997
SOURCE
Review of Scientific Instruments;Jan1997, Vol. 68 Issue 1, p500
SOURCE TYPE
Academic Journal
DOC. TYPE
Article
ABSTRACT
Discusses the fabrication of a millimeter-wave two-dimensional imaging array for the diagnosis of plug-cell plasma of the GAMMA 10 tandem mirror. Design of the heterodyne system; Measurement of the time evolution of the axial and radial line-density profiles; Fluctuation spectra of the electron cyclotron emission signals.
ACCESSION #
630761

 

Related Articles

  • Single-mode operation of a submillimeter wave gyrotron at the third-harmonic resonance. Idehara, T.; Tatsukawa, T.; Ogawa, I.; Wada, S.; Yoshizue, K.; Inoue, F.; Brand, G. F. // Physics of Fluids B: Plasma Physics;Apr92, Vol. 4 Issue 4, p769 

    If gyrotrons are to attain higher frequencies, high harmonic operation is necessary. In this Letter, the single-mode operation of a submillimeter wave gyrotron at the third harmonic of the electron cyclotron frequency is reported.

  • Millimeter-wave phase-imaging interferometer for the GAMMA 10 tandem mirror. Hattori, K.; Mase, A.; Itakura, A.; Inutake, M.; Miyoshi, S.; Uehara, K.; Yonekura, T.; Nishimura, H.; Miyashita, K.; Mizuno, K. // Review of Scientific Instruments;Dec1991, Vol. 62 Issue 12, p2857 

    A millimeter-wave phase-imaging interferometer has been developed for the study of density profiles of the GAMMA 10 tandem mirror. The interferometer uses a 70-GHz klystron oscillator and a quasi-optical transmission system. The probe beam is expanded so as to fill an orthogonal view of a plasma...

  • Numerical study of polarization-dependent focusing for a bilayer planar FSS reflective lens at millimeter wavelengths. Bliznyuk, Natalia; Engheta, Nader // Microwave & Optical Technology Letters;3/5/2004, Vol. 40 Issue 5, p361 

    In this paper, we numerically analyze the polarization-dependent focusing properties of a planar reflective lens formed by two parallel layers of nonuniform “gangbuster” surfaces (GSs) above a ground plane. Since these GSs consist of superdense arrays of thin finite-length parallel...

  • Millimetre-wave end-fired antenna array for active 3D holographic imaging system. Weihai Fang; Peng Fei; Feng Nian // Electronics Letters;2/27/2014, Vol. 50 Issue 5, p1 

    A compact Ka-band (26.5-40 GHz) dielectric rod end-fired antenna array for the three-dimensional (3D) active holographic imaging system is presented. Without horn shape feeding, the new antenna array is specially designed with characteristics such as small size, high gain, good radiation...

  • Active MMW/Terahertz Security System Based on Bessel Beams. Minin, Igor; Minin, Oleg // ISRN Optics;2013, p1 

    The novel concept of the security system based on THz Bessel beams is offered. The system is based on a novel THz diffractive optics for scanning the person (without the application of THz laser) and on a sensitive scheme for the detection of the reflected and scattered THz radiation. The...

  • 94 GHz Radiometer for Benchmarking its Operational Parameters for the Remote Detecton of Concealed Threat. Kumar, Ashok; Jassal, B. S. // Defence Science Journal;Sep2015, Vol. 65 Issue 5, p367 

    Standoff detection of concealed threat, using millimeter wave radiometer, is being experimented worldwide for enhancing the frame rate and detection probability, as an alternative to personnel frisking, for enhancing passenger service rate and avoiding exposure to harmful radiations. The...

  • Millimetre wave imaging system parameters at 95 GHz. Zhang, L.; Hao, Y.; Parini, C.G. // IET Microwaves, Antennas & Propagation;Jun2011, Vol. 5 Issue 5, p528 

    Millimetre wave imaging system parameters such as imaging array element spacing, imaging array dimension and imaging system resolution at 95 GHz are specified theoretically and verified in the prototype imaging system developed in the author's group. The effectiveness for concealed target...

  • Microsemi Boosting Millimeter Wave Technology Capability with Brijot Purchase.  // TR2: Terror Response Technology Report;9/28/2011, Vol. 7 Issue 20, p3 

    This article reports on the acquisition of Brijot Imaging Systems, a developer and supplier of millimeter wave imaging solutions, by Microsemi Corp. in 2011. The acquisition aims to enhance the capabilities of Microsemi in millimeter wave technology. David Hall, vice president of Microsemi, said...

  • Dual-tunable hybrid wave hexaferrite-ferroelectric millimetre-wave phase shifter. Grigoryeva, N.Y.; Sultanov, R.A.; Kalinikos, B.A. // Electronics Letters;1/6/2011, Vol. 47 Issue 1, p35 

    A novel electrically and magnetically tunable microwave phase shifter based on forward volume spin wave propagation in a layered structure containing films of oriented barium ferrite (BaM) and polycrystalline ferroelectric barium strontium titanate (BSTO) is proposed. Operating characteristics...